Call Us: 877-665-5666

X2

$355.00

The X2 is now part of the Foundation Series of embedded I/O controllers. All units feature a built-in logic engine, operator interface, networking and I/O. Use the dropdown below to select from our two distinct models:  X2R (relay outputs) and X2A (digital outputs)

Select part number below to view availability. If out of stock – please CALL FACTORY for lead time (USD).

To try out an X2 Starter Kit CLICK HERE

 

SKU: N/A Category:

Description

X2

MINIMAL PHYSICAL DESIGN 

The small, sleek profile of the X2 enables you to fit more in your panel, saving space and resources. For an introductory product, it packs a big picture into an overall small package. With just a 4.6” x 3.5” cutout, its overall design is powerful, reliable, and durable.

COMPREHENSIVE I/O CONFIGURATION 

In an effort to make implementing Horner OCS controllers as seamless and user-friendly as possible, we have selected a streamlined set of on-board I/O. The wide scope of digital and analog I/O make automating your applications, and your organization, as simple as the push of a button. If the built-in I/O of the X2 isn’t enough for your specific application, you can easily expand via CAN or serial.

FLEXIBILITY

In the market of fixed I/O, stand-alone controllers, the X2 is unmatched. Suited for most applications across a diverse range of industries, this controller exceeds standards (and expectations). The intuitive user interface, rugged durability, and suite of capabilities within the controller are similar to our more established XL line of products.

COMPETITIVE ADVANTAGE 

With the addition of the X2 OCS controller, our engineers at Horner Automation have designed a slim, versatile, and complimentary product to our existing line of robust industrial solutions. The X2, when utilized as an introductory piece, empowers your organization to grow by seamlessly incorporating additional Horner solutions (such as our more advanced X4 or premium X5 OCS controllers) to your expanding system.

Model Lineup

Built-In Inputs/OutputsHE-X2A (Model A)HE-X2R (Model R)
DC In1212
DC Out122
Relaysn/a6
HS In44
HS Out22
mA In4 4
mA Out22
Note: There are four high-speed inputs of the total DC Inputs. There are two high-speed outputs of the total DC outputs.
Note: Model A supports sourcing outputs. Model R DC outputs are sinking with integral pull up resistors.

Specifications

CONTROLLER
Ladder Logic Memory256 kB
Logic Scan Rate1.2 mS/K
Removable MemorymicroSD
Local Comment StorageYes
Floating Point SupportYes (32-bit)
AutoTune PID CapableYes (4 loops)
OPERATOR INTERFACE INTERFACE
Characters / Pixels128 x 64
Display Technology2.2" Monochrome LCD
Character HeightSelectable Fonts
Number of Pages250
Fields or Objects per Page15
Total Keys20
Function Keys10
OEM Faceplate AvailableNo
I/O
Built-in I/O Points26 (Model R); 30 (Model A)
SmartStix, SmartRail, SmartBlock I/O Supportyes, CsCAN
Digital Inputs / Outputs, max1024 / 1024
Analog Inputs / Outputs, max512 / 512
General Purpose Registers (words)5000 r
General Purpose Internal Coils (bits)2,048 (1,024 retentive)
SERIAL COMMUNICATIONS
Total Active Ports2
RS-232 Ports / RS-485 PortsRS-232 / RS-485 (1 of each)
PLC / Drive ProtocolsYes
RTU / Modbus Master / SlaveYes
Serial ASCII In / OutYes
USB Ports (A and Mini-B)Mini-B only for programming
ETHERNET/INTERNET
LAN Ports0
Factory Protocolsn/a
IIoT & Remote Accessn/a
Other Protocolsn/a
NETWORKING
Integrated CAN NetworksStandard
Supported CAN NetworksCsCAN
Maximum CAN Distance1,640 ft.
Programming over CAN Yes
PHYSICAL SPECIFICATIONS
Height4.69″ / 119.18 mm
Width3.53″ / 89.76 mm
Total Depth1.29″ / 32.7 mm
OPERATING SPECIFICATIONS & STANDARDS
Operating Temperature-10 to 60°C
Humidity (non-condensing)5 to 95%
Voltage24 +/-20% VDC
Product CertificationsCE, C’
Environmental RatingUL 50E Type 1, 4x (indoor use only), 12, 12k, 13

Documentation & Resources

DocumentReference NumberLink to Download
SALES LITERATURE
Foundation Series SheetHA-461
OCS Selection GuideHA-448
Starter Kit Sales SheetHA-345
DRAWINGSElectrical (DWG)2D Mechanical (DWG / PDF)3D Mechanical (STP / IGS)
HE-X2A / HE-X2R
TECHNICAL DOCUMENTATION
X2 User ManualMAN1130Download
X2 DatasheetMAN1131Download
X2 Quick Reference GuideMAN1132Download
SUPPLEMENTAL
App Guide for Updating FirmwareMAN1011
OCS Protocol/Software Licenses Guide
Cutout Template SheetSUP1551

Certifications

Certification TypeDownload Certificate
UL
CE Declaration of Conformity
ISO 9001: 2015
Lithium Battery Test Summary

Videos

For more X2 and other videos, please visit our YouTube Channel

Firmware Review Notes

PRODUCTVERSIONRELEASE DATETYPEDETAILSREQUIREMENTS
X2CSCAN 15.90August 2026EnhancementAdded support for ASCII username and password
Note: Requires Cscape 10.2 SP3 onwards
X2CSCAN 15.90August 2026EnhancementAdded X1 (India only) support
Note: Requires Cscape 10.2 SP3 onwards
X2CSCAN 15.90August 2026Bug FixResolved: Autotune would not function if a non-zero value was set for the Minimum Slew Time
X2CSCAN 15.90August 2026Bug FixResolved: An existing .pgm file was not being loaded.
X2CSCAN 15.80April 2026EnhancementApplicable to X2, XLE/e, XLT/e - Added support to apply a license through the SR register and the System MenuBootloader
X2CSCAN 15.80April 2026EnhancementApplicable to XLEe and XLTe only - Added WebMI 2.0 support
Note – Requires Cscape 10.2 SP2 onwards
Bootloader
X2CSCAN 15.80April 2026Bug FixResolved: Device displayed an exception when an IEC program was configured with a Modbus Master block and an array of structures was enabled.Bootloader
X2CSCAN 15.80April 2026Bug FixResolved: The GE SNP protocol was not working over full-duplex RS-485 communication.
Note –
• Requires SNP DLL v5.02 onwards
• Requires Cscape 10.2 SP2 onwards
Bootloader
X2CSCAN 15.80April 2026Bug FixResolved: The negative Y-axis values were not plotted correctly in trend graphs.Bootloader