Call Us: 877-665-5666

XLE

Price range: $643.00 through $1,286.00

1 in stock (can be backordered)

All XLE units feature a built-in logic engine, operator interface, networking and I/O.

Please select the model number from the dropdown to see current stock and pricing.
Current lead time is 2 – 6 weeks.

*FOR ETHERNET VERSION OF THIS PRODUCT, PLEASE SEE OUR XLEe

 

This controller is BABAA Compliant

 

Description

XLE

Features of the XLE Operator Interface include:

  • 128×64 graphical display
  • 20-key keypad with function key and numeric entry capability
  • Logic engine features 256KB of application memory with a 0.7mS/K logic scan.
  • (2) RS-232/485 ports support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable  protocols
  • integrated CsCAN port
  • Removable Mass Storage device
  • CANopen Master/Slave Support

Model Lineup

CONTROLLER MODELCONFIGURATION
HE-XE100No built-in I/O
HE-XE10212 DC in, 6 Relay Out, 4 – 12-bit Analog In
HE-XE10312 DC in, 12 DC Out, 2 – 12-bit Analog In
HE-XE10424 DC in, 16 DC Out, 2 – 12-bit Analog In
HE-XE10512 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out
HE-XE10612 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out
SPECIAL ORDER (*)
Part Number ExtensionDescription
-10Thermistor option. Add -10 to the part number for Thermistor support for Analog Inputs 1 & 2. Models 2, 3, and 4 only.
-14Thermistor option. Add -14 to the part number for (4) Channel Thermistor support. Model 2 only.
-22With Display Heater
-33DeviceNet Master option. Add -33 to the part number for DeviceNet Master Support (Polled & Explicit Connections only). CsCAN support is removed.
-44SAE J1939 Option. Add -44 part number extension for SAE J1939 communications. CsCAN support is removed.
-200CAN Open Firmware pre-loaded. CsCAN support is removed. OBS as of 3-1-26. Will be Cscape selectable on Gen 3
-602Screw type I/O terminals. Replaces spring type terminals. Model 6 only.
-603With Display Heater and Screw type I/O terminals. Replaces spring type terminals. Model 6 only
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks.
For combinations of adder options, please contact the factory – 877.665.5666

Specifications

CONTROLLER
Ladder Logic Memory256 KB
Logic Scan Rate0.7 mS/K
Removable MemorymicroSD
Local Comment StorageYes
Floating Point SupportYes
AutoTune PID CapableYes
OPERATOR INTERFACE
Characters / Pixels128x64
Display TechnologyTransflective LCD
Character Heightselectable fonts
Number of Pages1023
Fields or Objects per Page50
Total Keys20
Function Keys10
OEM Faceplate AvailableYes
I/O
Built-in I/O Points22-44
SmartStix, SmartRail, SmartBlock I/O Supportyes, CsCAN
Digital Inputs / Outputs, max2048 / 2048
Analog Inputs / Outputs, max512 / 512
General Purpose Registers (words)9,999
General Purpose Internal Coils (bits)4,096 (2,048 retentive)
ETHERNET/INTERNET
Ethernet SupportHE-XEC
Remote Accessvia EnvisionRV
Remote File Accessvia EnvisionFX
SERIAL COMMUNICATIONS
Total Active Ports2
RS-232 Ports / RS-485 PortsRS-232 / RS-485 (x2)
PLC / Drive ProtocolsYes
RTU / Modbus Master / SlaveYes
Serial ASCII In / OutYes
USB Ports (A and Mini-B)no
NETWORKING
Integrated CAN Networks1
Supported CAN NetworksCsCAN, CANopen (firmware change), DeviceNet Master (-33 option), SAE J1939 (-44 option)
Maximum CAN Distance500m per segment, 4 segments maximum
Programming over CAN       CsCAN only
PHYSICAL SPECIFICATIONS
Height3.780" / 96.00 mm
Width3.780" / 96.00 mm
Depth2.264" / 57.5 mm
I/O Module DepthCOM option adds 0.5" / 13 mm depth
OPERATING SPECS & STANDARDS
Operating Temperature*-10 to 60°C, *Note: -22 to -40°C Low Temp Option, Contact Factory for Low Temp Options
Humidity (non-condensing)5 to 95%
Product CertificationsCE, C', UL Class 1 Div II,
Environmental RatingNEMA & UL Type 1, 3R, 4, 4x, 12, 12k, 13, ABS

Documentation and Resources

DocumentReference NumberLink to Download
SALES LITERATURE
XL Series Comparison GuideHA-374
DRAWINGS2D ELECTRICAL2D MECHANICAL3D MECHANICAL
HE-XE100 Model 0
HE-XE102 Model 2
HE-XE103 Model 3
HE-XE104 Model 4
HE-XE105 Model 5
HE-XE106 Model 6
TECHNICAL DOCUMENTATION
XLE User ManualMAN0878Download
XLE Quick Reference GuideMAN1122Download
HE-XE100 DatasheetMAN1112Download
HE-XE102 DatasheetMAN1113Download
HE-XE103 DatasheetMAN1114Download
HE-XE104 DatasheetMAN1115Download
HE-XE105 DatasheetMAN1116Download
HE-XE106 DatasheetMAN1117Download
SUPPLEMENTAL
App Guide for Updating FirmwareMAN1011Download
Ethernet Supplement ManualSUP0740Download
Thermistor SupplementSUP0797
Cutout Template SheetSUP1551

Certifications

Certification TypeDownload Certificate
BABAA - Build America, Buy America Act
UL
CE Declaration of Conformity
ISO 9001: 2015
ABS
Lithium Battery Test Summary

Videos

Firmware Review Notes

PRODUCTVERSIONRELEASE DATETYPEDETAILSREQUIREMENTS
XLE/XLEeCSCAN 15.70March 2026EnhancementAdded “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu.
Note: Requires Cscape 10.2 onwards
XLE/XLEeCSCAN 15.70March 2026EnhancementSecurity improvements :
Ethernet ports open only if they are configured in Cscape and downloaded to the device.
XLE/XLEeCSCAN 15.70March 2026EnhancementAdded logging of “return” state alarms, wherein if the alarm was acknowledged, but is still in the alarm state, after the alarm returns to normal, the return was not being logged.
XLE/XLEeCSCAN 15.70March 2026EnhancementAdded System Register bit for the restore operation from logic.
• Restore operation: %SR164.16
XLE/XLEeCSCAN 15.70March 2026EnhancementAdded System Register bit for indicating the status of CAN port
• %SR4.14 indicates a CAN port error and may require a power cycle to recover.
XLE/XLEeCSCAN 15.70March 2026EnhancementThe “Set Local ID” option is supported for both CsCAN and CANOpen network types.
Note: Requires Cscape version 10.1 onwards
XLE/XLEeCSCAN 15.70March 2026Bug FixResolved: Loading a .pgm file did not match the exact model of the OCS, and did not display any error message on the device.
XLE/XLEeCSCAN 15.70March 2026Bug FixEnhanced filename (RM blocks, PGM) support from 8 characters to 47 characters.
XLE/XLEeCSCAN 15.70March 2026Bug FixImproved auto-populate feature in OCSIO
Note: Requires CNX116 / CNX100 FW Version 48 onwards.
XLEe onlyCSCAN 15.70March 2026Bug FixResolved: The Dynamically configured IP address was not editable using the System Menu in Idle mode.
XLEe onlyCSCAN 15.70March 2026Bug FixResolved: (ASCII over TCP/IP) Device status was not displayed correctly after disconnecting and reconnecting the server.
XLEe onlyCSCAN 15.70March 2026Bug FixResolved: Ethernet/IP protocol stops working if the Consumed / Produced configuration exceeds 128 Words.
XLEe onlyCSCAN 15.70March 2026Bug FixResolved the following issues related to WebMI:
• FTP error was being displayed while publishing webpages after a power cycle.
• WebMI pages not loading – Web pages were not being loaded after sign in.
XLE/XLEeCSCAN 15.62August 2023EnhancementAdded OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwardsBootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein timer output was turning on at startup (7639)Bootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634)Bootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe onlyBootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only.Bootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only.Bootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe onlyBootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only.Bootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only.Bootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717)Bootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only.Bootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only.Bootloader
XLE/XLEeCSCAN 15.62August 2023Bug FixResolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only.Bootloader
XLE/XLEeDownload Firmware 15.62 Release Notes
XLE/XLEeCSCAN 15.60February 2023Bug FixResolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587)Bootloader
XLE/XLEeCSCAN 15.60February 2023Bug FixApplicable to XLEe / XLTe only
Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258)
Bootloader
XLEe onlyCSCAN 15.58March 2022New FeatureResolved issue when WebMI license details on System Menu were not retained if ethernet cable orBootloader
XLEe onlymicroSD card was removed. (9554/1258)

You may also like…