All XLE units feature a built-in logic engine, operator interface, networking and I/O.
Please select the model number from the dropdown to see current stock and pricing.
Current lead time is 2 – 6 weeks.
All XLE units feature a built-in logic engine, operator interface, networking and I/O.
Please select the model number from the dropdown to see current stock and pricing.
Current lead time is 2 – 6 weeks.
Features of the XLE Operator Interface include:
CONTROLLER MODEL | CONFIGURATION |
---|---|
HE-XE100 | No built-in I/O |
HE-XE102 | 12 DC in, 6 Relay Out, 4 – 12-bit Analog In |
HE-XE103 | 12 DC in, 12 DC Out, 2 – 12-bit Analog In |
HE-XE104 | 24 DC in, 16 DC Out, 2 – 12-bit Analog In |
HE-XE105 | 12 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out |
HE-XE106 | 12 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out |
SPECIAL ORDER (*) | |
Part Number Extension | Description |
-10 | Thermistor option. Add -10 to the part number for Thermistor support for Analog Inputs 1 & 2. Models 2, 3, and 4 only. |
-14 | Thermistor option. Add -14 to the part number for (4) Channel Thermistor support. Model 2 only. |
-22 | With Display Heater |
-33 | DeviceNet Master option. Add -33 to the part number for DeviceNet Master Support (Polled & Explicit Connections only). CsCAN support is removed. |
-44 | SAE J1939 Option. Add -44 part number extension for SAE J1939 communications. CsCAN support is removed. |
-200 | CAN Open Firmware pre-loaded. CsCAN support is removed. |
-602 | Screw type I/O terminals. Replaces spring type terminals. Model 6 only. |
-603 | With Display Heater and Screw type I/O terminals. Replaces spring type terminals. Model 6 only |
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks. | |
For combinations of adder options, please contact the factory – 877.665.5666 |
CONTROLLER | |
Ladder Logic Memory | 256 KB |
Logic Scan Rate | 0.7 mS/K |
Removable Memory | microSD |
Local Comment Storage | Yes |
Floating Point Support | Yes |
AutoTune PID Capable | Yes |
OPERATOR INTERFACE | |
Characters / Pixels | 128x64 |
Display Technology | Transflective LCD |
Character Height | selectable fonts |
Number of Pages | 1023 |
Fields or Objects per Page | 50 |
Total Keys | 20 |
Function Keys | 10 |
OEM Faceplate Available | Yes |
I/O | |
Built-in I/O Points | 22-44 |
SmartStix, SmartRail, SmartBlock I/O Support | yes, CsCAN |
Digital Inputs / Outputs, max | 2048 / 2048 |
Analog Inputs / Outputs, max | 512 / 512 |
General Purpose Registers (words) | 9,999 |
General Purpose Internal Coils (bits) | 4,096 (2,048 retentive) |
ETHERNET/INTERNET | |
Ethernet Support | HE-XEC |
Remote Access | via EnvisionRV |
Remote File Access | via EnvisionFX |
SERIAL COMMUNICATIONS | |
Total Active Ports | 2 |
RS-232 Ports / RS-485 Ports | RS-232 / RS-485 (x2) |
PLC / Drive Protocols | Yes |
RTU / Modbus Master / Slave | Yes |
Serial ASCII In / Out | Yes |
USB Ports (A and Mini-B) | no |
NETWORKING | |
Integrated CAN Networks | 1 |
Supported CAN Networks | CsCAN, CANopen (firmware change), DeviceNet Master (-33 option), SAE J1939 (-44 option) |
Maximum CAN Distance | 500m per segment, 4 segments maximum |
Programming over CAN | CsCAN only |
PHYSICAL SPECIFICATIONS | |
Height | 3.780" / 96.00 mm |
Width | 3.780" / 96.00 mm |
Depth | 2.264" / 57.5 mm |
I/O Module Depth | COM option adds 0.5" / 13 mm depth |
OPERATING SPECS & STANDARDS | |
Operating Temperature* | -10 to 60°C, *Note: -22 to -40°C Low Temp Option, Contact Factory for Low Temp Options |
Humidity (non-condensing) | 5 to 95% |
Product Certifications | CE, C', UL Class 1 Div II, |
Environmental Rating | NEMA & UL Type 1, 3R, 4, 4x, 12, 12k, 13, ABS |
Document | Reference Number | Link to Download | |
---|---|---|---|
SALES LITERATURE | |||
Sales Sheet for XLE and XLEe | HA-288 | ||
XL Series Comparison Guide | HA-102 | ||
DRAWINGS | 2D ELECTRICAL | 2D MECHANICAL | 3D MECHANICAL |
HE-XE100 Model 0 | |||
HE-XE102 Model 2 | |||
HE-XE103 Model 3 | |||
HE-XE104 Model 4 | |||
HE-XE105 Model 5 | |||
HE-XE106 Model 6 | |||
TECHNICAL DOCUMENTATION | |||
XLE User Manual | MAN0878 | Download | |
XLE Quick Reference Guide | MAN1122 | Download | |
HE-XE100 Datasheet | MAN1112 | Download | |
HE-XE102 Datasheet | MAN1113 | Download | |
HE-XE103 Datasheet | MAN1114 | Download | |
HE-XE104 Datasheet | MAN1115 | Download | |
HE-XE105 Datasheet | MAN1116 | Download | |
HE-XE106 Datasheet | MAN1117 | Download | |
SUPPLEMENTAL | |||
App Guide for Updating Firmware | MAN1011 | Download | |
Ethernet Supplement Manual | SUP0740 | Download | |
Thermistor Supplement | SUP0797 |
Certification Type | Download Certificate |
---|---|
UL | |
CE Declaration of Conformity | |
ISO 9001: 2015 | |
ABS | |
Lithium Battery Test Summary |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XLE/XLEe | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe only | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe only | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | Download Firmware 15.62 Release Notes | |||||
XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
XLEe only | CSCAN 15.58 | March 2022 | New Feature | Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or | Bootloader | |
XLEe only | microSD card was removed. (9554/1258) | |||||
XLE/XLEe | CSCAN 15.56 | September 2021 | Enhancement | WebMI status bits have been added for session Count - %SR101.5 to SR101.7. (4980) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolve issue when occasionally microSD card was not detecting / reading properly when card was plugged and unplugged repeatedly. (4703) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved the following issues (5398) - a. Packets were getting delayed beyond the set update interval when the update interval option was selected in the Client Protocol b. Previous sockets were getting closed before sending the reconnect packet | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved WebMI issue that if previous sessions were not getting closed, then a connection timeout occurred during long run as max sessions were reached. (4980) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved issue when ModbusTCP communication was not starting until Reacquire Time had timed out during power up or occasionally when unit was moved from Idle to Run mode. (5042) | Bootloader | |
XLE/XLEe | Download Firmware 15.56 Release Notes | |||||
XLE/XLEe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when Modbus communication on MJ2 stops working and unit locks up. (2769) | Bootloader | |
XLEe only | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when MJ1 RS 232 Handshake fails on XLEe Generation 2 (Data Set Ready / DSR) - issue related to Modem. (5171) | Bootloader | |
XLE/XLEe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue where in Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
XLE/XLEe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when using the Report Editor, an extra | Bootloader | |
XLE/XLEe | Download Firmware 15.54 Release Notes | |||||
XLE/XLEe | CSCAN 15.52 | May 2021 | Enhancement | Increased ladder size from 256KB to 512KB. (4318) | Bootloader | |
XLE/XLEe | CSCAN 15.52 | May 2021 | Bug Fix | XLE/XLEe and XLT/XLTe only - Resolved issue where stepper count was off by 1 or 2 in second generation XLE. (4004) | Bootloader | |
XLEe only | CSCAN 15.52 | May 2021 | Bug Fix | XLEe and XLTe only - Resolved issue where email was not working if Modbus TCP was configured. (3711) | Bootloader | |
XLE/XLEe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943) | Bootloader | |
XLE/XLEe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646) | Bootloader | |
XLE/XLEe | Download Firmware 15.52 Release Notes | |||||
XLE/XLEe | CSCAN 15.44 | January 2021 | Bug Fix | In rare cases, analog inputs of Model 5 I/O will not update at power up or can stop updating during operation. | Hardware rev TU and later | |
XLE/XLEe | CSCAN 15.44 | January 2021 | Bug Fix | Using the stepper count function will result in extra pulses beyond the setpoint. | Hardware rev TU and later | |
XLE/XLEe | CSCAN 15.44 | *NOTE: If upgrading from Firmware 15.40, a power cycle is required when the firmware upgrade is complete. | ||||
XLE/XLEe | Download Firmware 15.44 Release Notes | |||||
XLE/XLEe | CSCAN 15.24 | January 2020 | Bug Fix | Could not load 15.20 Firmware and new CPLD on new blank XLE units. | ||
XLE/XLEe | CSCAN 15.24 | January 2020 | * NOTE: Does not affect post-production units that are flashed with earlier versions | |||
XLE/XLEe | Download Firmware 15.24 Release Notes | |||||
XLE only | CSCAN 15.18 | January 2019 | Bug Fix | Reduce unnecessary current draw (without power) on the Backup Battery. | Rev TA-VD | |
XLE only | Download PUN Notes for Power Loss Details | |||||
XLE only | Download Firmware 15.18 Release Notes |