X4 | FW 15.90 | February 2025 | Enhancement | Added support for OCSIO DQM602. | |
X4 | FW 15.90 | February 2025 | Enhancement | Added retain variables support for Variable-Based Advanced Ladder (VBAL). Note: Requires Cscape version 10.1 onwards. | |
X4 | FW 15.90 | February 2025 | Enhancement | Added System Register bit for system menu access.
Note: Requires Cscape version 10.1 onwards. | |
X4 | FW 15.90 | February 2025 | Enhancement | Added “Alpha Filter Constant” function for analog inputs.
Notes:
• Requires Cscape version 10.1 onwards
• Ranges from 1 – 10 (1 refers to 0.01 filtering and 10 refers to 0.1 filtering)
• The lower the value, the heavier the filtering | |
X4 | FW 15.90 | February 2025 | Bug Fix | Resolved: The momentary button was behaving as if it was a toggle button when it was placed at the top right corner of the screen. | |
X4 | FW 15.90 | February 2025 | Bug Fix | Resolved: Read RM block was reading entire elements/data for an ASCII data type instead of reading only the configured number of elements. | |
X4 | FW 15.90 | February 2025 | Bug Fix | Resolved: Time/date object was not displaying data correctly on web pages when the user refreshed the web pages. | |
X4 | FW 15.90 | February 2025 | Bug Fix | Resolved: User was seeing a delay of up to 10 seconds when trying to trigger a data write operation in ASCII TCP/IP Client protocol (when the slave device was re-establishing the connection)
Notes:
• Provided a setting in the protocol network configuration to control the serversion reconnection interval (Fast-2 Seconds, Medium-5 Seconds, Slow-10 Seconds).
• This requires ASCII TCP/IP Protocol dll v5.04 onwards. | |
X4 | FW 15.90 | | | Download Firmware 15.90 Release Notes | | |
X4 | FW 15.82 | April 2024 | Enhancement | Resolved issue where System menu | View Status displays both Build version and Firmware version. | |
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where unit locked up / froze when serial downloadable protocol was configured. This occurred randomly and was seen in limited hardware | |
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where hardfault errors occur when CANopen SmartRail is configured in the program and downloaded | |
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where endless loop of nameless folders were being created when "A:\" in Copy RM block was entered by the user. | |
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where title bar of password object was showing mixed characters when unicode fonts were created. | |
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where WebMI alarm history page not listing the RTN alarms | |
X4 | FW 15.82 | | | Download Firmware 15.82 Release Notes | | |
X4 | CSCAN 15.78 | October 2023 | Enhancement | Added CNX100 support for Micro OCS Series.
NOTE: Requires Cscape v. 9.90 SP10 onwards. | |
X4 | CSCAN 15.78 | October 2023 | Enhancement | Added BACNet MSTP downloadable protocol support for Micro OCS Series.
NOTE: Requires Cscape v. 9.90 SP11 onwards. | |
X4 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved issue wherein device was displaying exception for a specific program which had Copy_CF block tagged with register greater than %R2048 in IEC languages. (7631) | |
X4 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved issue where in unit displayed "User Program: Fault" or "APP CRC" error at bootup. (10795) | |
X4 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved Cscape connectivity issue via ethernet communication when running EGD protocol. (10761) | |
X4 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved X10 reset issue when multiple error messages were received by the controller for serial communication protocols. (10840) | |
X4 | CSCAN 15.76 | July 2023 | Enhancement | OCSIO support has been added along with new modules - DIM610 and DQM606. NOTE: New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | |
X4 | CSCAN 15.76 | July 2023 | Enhancement | Increased PID blocks support from 4 to 8 for Micro OCS series. NOTE: Requires Cscape 9.90 SP9 onwards. | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved erasing of analog calibration information after updating to FW 15.70 (10418) NOTE: Addressed issue related to both upgrade and downgrade of firmware. | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved touch calibration issue after loading FW 15.70 (10553) NOTE: The cross hair at the upper left of the screen does not work in Touch Calibration | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when timer output was turning on at startup. (7639 / 1390) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when after power cycle, the first pulse output duration was either missed or too short. (7634) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when Filename Counter was not working properly if a file with screen capture was downloaded previously. (5717) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when unit would lose communication with Cscape over Ethernet when there were multiple slaves configured in the program but not connected. (4700) NOTE: Occurrence of issue has been reduced | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when WebMI license was lost if there was a flat or faulty controller battery. License duration check will not be done for lifetime licenses, so even if battery fails, license will be valid for lifetime licenses. (3429) NOTE: For permanent license, check for RTC time has been removed | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when screen response to Momentary Button was not working properly for a large button configured on the screen. (8439) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when screen saver was not working for a few hardware revisions. (8018) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when frequent timeouts and reconnects were seen on units running EtherNet/IP server. (8541) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue with Modbus TCP communication when 6 or more devices were used. (8362) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when combining characters like Thai fonts were not displayed properly in the Graphics Editor. (3878) NOTE: Requires Cscape 9.90 SP9 onwards. | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464 / 7052 / 7508) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved flash erase issue on a few hardware revisions after loading 15.60 firmware. (9197) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when user access alarms webpage via web designer model device displayed HardFault error. (8288) NOTE: Issue was seen when unicode strings were configured in alarms configuration. | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when device displayed HardFault error when Modbus TCP/IP device list configured with more than 32 slaves was downloaded to device. (7495 / 8531) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when emails sent from the OCS were being treated as spam emails due to email header missing time zone. (9105) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when Quadrature HSC output was not working. (6468) | |
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when accessing webpages used to display frequent "connection timeout". (9869 / 7583) | |
X4 | CSCAN 15.76 | | | Download Firmware 15.76 Release Notes | | |
X4 | CSCAN 15.60 | December 2022 | Bug Fix | Resolved input glitch caused by beeper function. | Bootloader |
X4 | CSCAN 15.60 | | | Download Firmware 15.58 Release Notes | | |