Call Us: 877-665-5666

EXLW

Build to order – Standard lead times are 2-6 weeks.

All units feature a built-in logic engine, operator interface, networking and I/O.

Please select the model number from the dropdown to see current stock and pricing.

Current lead time is 2 – 6 weeks.

 

 

For more details on a complete, pre-programmed solution using the EXLW click below –

                       

 

 

Please login to see price/buy item.

Description

The EXLW Logic engine features 1MB of application memory with a 0.04 mS/K logic scan. Online Programming Mode (making logic changes on the fly without going thru stop mode) is supported. Operator Interface features include:

  • 800×480 LCD TFT color graphics display with a high resolution resistive touchscreen
  • USB 2.0 On-the-Go port (mini-B 5pin) is available for programming
  • USB 2.0 Host port (A) is available for exchanging files with USB FLASH drives
  • Two (2) RS-232 and one (1) RS-485 port support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols

Networking features include:

  • Built-in 10/100 Ethernet port
  • Integrated CsCAN port

All EXLW units feature a microSD slot, supporting at least 32GB.

Model Lineup

CONTROLLER MODELCONFIGURATION
HE-EXLWE0No built-in I/O
HE-EXLWE212 DC in, 6 Relay Out, 4 – 12-bit Analog In
HE-EXLWE312 DC in, 12 DC Out, 2 – 12-bit Analog In
HE-EXLWE424 DC in, 16 DC Out, 2 – 12-bit Analog In
HE-EXLWE512 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out
HE-EXLWE612 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out
*Up To six mA/V In, mA/V RTD/Tc, and mA/V Out
SPECIAL ORDER (*)
Part Number Extension
-10Thermistor option. Add -10 to the part number for Thermistor support for Analog Inputs 1 & 2. Model 2, 3, 4 only.
-14Thermistor option. Add -14 to the part number for (4) Channel Thermistor support. Model 2 option only
-33DeviceNet Master option. Add -33 to the part number for DeviceNet Master Support (Polled & Explicit Connections only). CsCAN support is removed
-44SAE J1939 Option. Add -44 part number extension for SAE J1939 communications. CsCAN support is removed
-200CAN Open Firmware pre-loaded. CsCAN support is removed
-441WebMI License Unlimited pre-loaded
-442Enahnced IEC License pre-loaded
-445MQTT License is pre-loaded
-602Screw type I/O terminals. Replaces spring type terminals. Model 6 only
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks.
For combinations of adder options, please contact the factory – 877.665.5666

Specifications

CONTROLLER
Ladder Logic Memory1 MB
Logic Scan Rate0.04 mS/K
Removable MemorymicroSD
Local Comment StorageYes
Floating Point SupportYes
AutoTune PID CapableYes
OPERATOR INTERFACE
Characters / Pixels800x480
Display Technology7" TFT Color
Character Heightselectable fonts
Number of Pages1023
Fields or Objects per Page1023
Total Keys6
OEM Faceplate AvailableYes
I/O
Built-in I/O Points22-44
SmartStix, SmartRail, SmartBlock I/O Supportyes, CsCAN and Ethernet
Digital Inputs / Outputs, max2048 / 2048
Analog Inputs / Outputs, max512 / 512
General Purpose Registers (words)50000
General Purpose Internal Coils (bits)32768 (16384 retentive)
ETHERNET/INTERNET
Ethernet SupportStandard, 1 Port
Remote AccessWebMI, HTTP or EnvisionRV
Remote File AccessFTP or EnvisionFX
IIoT Support MQTT (Sparkplug)
SERIAL COMMUNICATIONS
Total Active Ports3
RS-232 Ports / RS-485 Ports1 RS-232 & 1 RS-485 on first Modular Jack (MJ1/2); 1 RS-232 or RS-485 on second Modular Jack (MJ3)
PLC / Drive ProtocolsYes
RTU / Modbus Master / SlaveYes
Serial ASCII In / OutYes
USB Ports (A and Mini-B)USB 2.0 (480 MHz) for USB FLASH Drives (2TB); USB 2.0 (480 MHZ) Programming & Data Access
NETWORKING
Integrated CAN Networks1
Supported CAN NetworksCsCAN, CANopen, J1939 and DeviceNet Master (layer 3 as a selectable option)
Maximum CAN Distance500m per segment, 4 segments maximum
Programming over CAN       CsCAN only
PHYSICAL SPECIFICATIONS
Height5.66" / 143.8 mm
Width7.34" / 186.08 mm
Depth3.03" / 77.0 mm
I/O Module DepthCOM option adds 0.98" / 24.83 mm depth
OPERATING SPECS & STANDARDS
Operating Temperature*-10 to 60°C
Humidity (non-condensing)5 to 95%
Product Certifications/ApprovalsUL Class 1 Div II, CE
Environmental RatingUL Type 1, 3R, 4, 4x, 12, 12k, 13

Documentation & Resources

DocumentReference NumberLink to Download
SALES LITERATURE
EXLW Sales SheetHA-330
XL Series Comparison GuideHA-102
DRAWINGS2D ELECTRICAL2D MECHANICAL3D MECHANICAL
HE-EXLWE0 Model 0
HE-EXLWE2 Model 2
HE-EXLWE3 Model 3
HE-EXLWE4 Model 4
HE-EXLWE5 Model 5
HE-EXLWE6 Model 6
Power Connector
CAN Connector
9 Pin 106 Connector
12 Pin 106 Connector
TECHNICAL DOCUMENTATION
EXLW User ManualMAN1256Download
EXLW Quick Reference GuideMAN1268Download
HE-EXLWE0 DatasheetMAN1257Download
HE-EXLWE2 DatasheetMAN1258Download
HE-EXLWE3 DatasheetMAN1259Download
HE-EXLWE4 DatasheetMAN1260Download
HE-EXLWE5 DatasheetMAN1261Download
HE-EXLWE6 DatasheetMAN1262Download
SUPPLEMENTAL
App Guide for Updating FirmwareMAN1011Download
App Guide for Adding Custom Splash ScreenMAN0990
Firmware Restore ManualMAN1141
Ethernet Supplement ManualSUP0740Download
Thermistor SupplementSUP0797

Certifications

Certification TypeDownload Certificate
UL
CE Declaration of Conformity
ISO 9001: 2015
Lithium Battery Test Summary

Firmware Review Notes

PRODUCTVERSIONRELEASE DATETYPEDETAILSREQUIREMENTS
EXLW15.709/20/24EnhancementAdded support for OCSIO models ADC270 and DQM602.Bootloader, Cscape 9.90 SP10
EXLW15.709/20/24EnhancementRetain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards.Bootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: Modbus Client sending Zero Value when Holding Register is Not ZeroBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: CAN2 stopped working after several power cyclesBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media blockBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: UTC time was not updating when downloaded from CscapeBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: Title bar of password object was showing nonsense language when Unicode fonts were createdBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: WebMI alarm history page not listing the RTN alarmsBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controllerBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: CV value of a PID block was not being updated when configured in the Enhanced IEC programBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocksBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elementsBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: Gmail was not working for certain SMTP IPsBootloader, Cscape 9.90 SP10
EXLW15.709/20/24Bug FixResolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view statusBootloader, Cscape 9.90 SP10
Download >Download Firmware 15.70 Release Notes
EXLW15.649/18/23EnhancementAdded support for OCS-I/O (CNX100) modules.Bootloader, Cscape 9.90 SP10
EXLW15.649/18/23Bug FixResolved issue wherein device would PING for an invalid subnet mask configured. (8765)Bootloader, Cscape 9.90 SP10
EXLW15.649/18/23Bug FixResolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC onlyBootloader, Cscape 9.90 SP10
EXLW15.649/18/23Bug FixResolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212)Bootloader, Cscape 9.90 SP10
EXLW15.649/18/23Bug FixResolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843)Bootloader, Cscape 9.90 SP10
EXLW15.649/18/23Bug FixResolved issue wherein only limited number of users configured in user security configuration were working. (10016)Bootloader, Cscape 9.90 SP10
Download >Download Firmware 15.64 Release Notes
EXLWCSCAN 15.62May 2023EnhancementOCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmwareBootloader
EXLWCSCAN 15.62May 2023EnhancementAdded new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345)
NOTE: This requires Cscape 9.90 SP9 onwards
%SR104–32bit %SR for storing password of program which is currently running
%SR106–32bit %SR for storing password of program which is being loaded
Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved ethernet port lock up issues. (8464)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards.Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved device was displaying exception when used Copy_CF block – IEC issue. (7631)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved Q1 output was not going TRUE after online change issue. (8713)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved alarm history was not listing all alarms on webpages issue. (1643)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642)
NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets
Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved loss of communication issues with BACNet MSTP protocol for X5. (8881)
NOTE: X5 only.
Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved communication issues with ethernet SmartRail bases. (8625)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045)Bootloader
EXLWCSCAN 15.62May 2023Bug FixAdded time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105)Bootloader
EXLWCSCAN 15.62May 2023Bug FixResolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843)
NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication.
Bootloader
EXLWDownload >Download Firmware 15.62 Release Notes
EXLWCSCAN 15.60November 2022EnhancementAdded register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143)Bootloader
EXLWCSCAN 15.60November 2022EnhancementOCS-I/O Support. Requires Cscape 9.90 SP8 onwards.Bootloader
EXLWCSCAN 15.60November 2022EnhancementModification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623)Bootloader
EXLWCSCAN 15.60November 2022Bug FixResolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233)Bootloader
EXLWCSCAN 15.60November 2022Bug FixResolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508)Bootloader
EXLWCSCAN 15.60November 2022Bug FixResolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461)Bootloader
Download Firmware 15.54 Release Notes

Videos

You may also like…

Go to Top