Call Us: 877-665-5666

XLT

Price range: $1,265.00 through $1,965.00

1 in stock (can be backordered)

All XLt units feature a built-in logic engine, operator interface, networking and I/O.  Logic engine features 256KB of application memory with a 1.2mS/K logic scan.

Please select the model number from the dropdown to see current stock and pricing (USD).

Current lead time is 2 – 6 weeks.

*FOR ETHERNET VERSION OF THIS PRODUCT, PLEASE SEE OUR XLTe

 

This controller is BABAA Compliant

 

Description

XLT

Features of the XLT Operator Interface include:

  • 160×128 sunlight readable graphics display
  • high resolution resistive touchscreen
  • 4 function keys and a system key
  • (2) RS-232/485 ports support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols
  • integrated CsCAN port
  • Removable Mass Storage device
  • CANopen Master/Slave Support (available as a field installable firmware update, this removes CsCAN support)

Model Lineup

CONTROLLER MODELCONFIGURATION
HE-XT100No built-in I/O
HE-XT10212 DC in, 6 Relay Out, 4 – 12-bit Analog In
HE-XT10312 DC in, 12 DC Out, 2 – 12-bit Analog In
HE-XT10424 DC in, 16 DC Out, 2 – 12-bit Analog In
HE-XT10512 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out
HE-XT10612 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out
SPECIAL ORDER (*)
Part Number ExtensionDescription
-10Thermistor option. Add -10 to the part number for Thermistor support for Analog Inputs 1 & 2. Models 2, 3, and 4 only.
-14Thermistor option. Add -14 to the part number for (4) Channel Thermistor support. Model 2 only.
-22With Display Heater
-33DeviceNet Master option. Add -33 to the part number for DeviceNet Master Support (Polled & Explicit Connections only). CsCAN support is removed.
-44SAE J1939 Option. Add -44 part number extension for SAE J1939 communications. CsCAN support is removed.
-602Screw type I/O terminals. Replaces spring type terminals. Model 6 only.
-603With Display Heater and Screw type I/O terminals. Replaces spring type terminals. Model 6 only
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks.
For combinations of adder options, please contact the factory – 877.665.5666

Specifications

CONTROLLER
Ladder Logic Memory256 KB
Logic Scan Rate0.8 mS/K
Removable MemorymicroSD
Local Comment StorageYes
Floating Point SupportYes
AutoTune PID CapableYes
OPERATOR INTERFACE
Characters / Pixels160x128
Display TechnologyTransflective LCD
Character Heightselectable fonts
Number of Pages1023
Fields or Objects per Page50
Total Keys5
Function Keys4
OEM Faceplate AvailableYes
I/O
Built-in I/O Points22-44
SmartStix, SmartRail, SmartBlock I/O Supportyes, CsCAN
Digital Inputs / Outputs, max2048 / 2048
Analog Inputs / Outputs, max512 / 512
General Purpose Registers (words)9,999
General Purpose Internal Coils (bits)4,096 (2,048 retentive)
ETHERNET/INTERNET
Ethernet SupportHE-XEC
Remote Accessvia EnvisionRV
Remote File Accessvia EnvisionFX
SERIAL COMMUNICATIONS
Total Active Ports2
RS-232 Ports / RS-485 PortsRS-232 / RS-485 (x2)
PLC / Drive ProtocolsYes
RTU / Modbus Master / SlaveYes
Serial ASCII In / OutYes
USB Ports (A and Mini-B)no
NETWORKING
Integrated CAN Networks1
Supported CAN NetworksCsCAN, CANopen (firmware change), DeviceNet Master (-33 option), SAE J1939 (-44 option)
Maximum CAN Distance500m per segment, 4 segments maximum
Programming over CAN       CsCAN only
PHYSICAL SPECIFICATIONS
Height3.780" / 96.00 mm
Width3.780" / 96.00 mm
Depth2.264" / 57.5 mm
I/O Module DepthCOM option adds 0.5" / 13 mm depth
OPERATING SPECS & STANDARDS
Operating Temperature*-10 to 60°C, *Note: -40°C Low Temp Option, Contact Factory
Humidity (non-condensing)5 to 95%
Product CertificationsCE, C', UL Class 1 Div II,
Environmental RatingNEMA & UL Type 1, 3R, 4, 4x, 12, 12k, 13, ABS

Documentation & Resources

DocumentReference NumberLink to Download
SALES LITERATURE
Foundation Series SheetHA-461
OCS Selection GuideHA-448
DRAWINGS2D ELECTRICAL2D MECHANICAL3D MECHANICAL
HE-XT1E0 Model 0
HE-XT1E2 Model 2
HE-XT1E3 Model 3
HE-XT1E4 Model 4
HE-XT1E5 Model 5
HE-XT1E6 Model 6
TECHNICAL DOCUMENTATION
XLT/XLTe User ManualMAN0878Download
XLT/XLTe Quick Reference GuideMAN1122Download
HE-XT1E0 DatasheetMAN1112Download
HE-XT1E2 DatasheetMAN1113Download
HE-XT1E3 DatasheetMAN1114Download
HE-XT1E4 DatasheetMAN1115Download
HE-XT1E5 DatasheetMAN1116Download
HE-XT1E6 DatasheetMAN1117Download
SUPPLEMENTAL
App Guide for Updating FirmwareMAN1011Download
Ethernet Supplement ManualSUP0740Download
Thermistor SupplementSUP0797
Cutout Template SheetSUP1551

Drawings

Model 0
HE-XT100 Electrical Drawings (dwg, pdf, visio)
HE-XT100 2D Mechanical Drawings (dwg, pdf)
HE-XT100 3D Mechanical Drawings (igs, stp)
Model 2
HE-XT102 Electrical Drawings (dwg, pdf, visio)
HE-XT102 2D Mechanical Drawings (dwg, pdf)
HE-XT102 3D Mechanical Drawings (igs, stp)
Model 3
Model 4
Model 5
Model 6

Certifications

Certification TypeDownload Certificate
BABAA - Build America, Buy America Act
UL
CE Declaration of Conformity
ISO 9001: 2015
ABS
Lithium Battery Test Summary

Videos

Firmware Review Notes

PRODUCTVERSIONRELEASE DATETYPEDETAILSREQUIREMENTS
XLT/XLTeCSCAN 15.80April 2026EnhancementApplicable to X2, XLE/e, XLT/e - Added support to apply a license through the SR register and the System MenuBootloader
XLT/XLTeCSCAN 15.80April 2026EnhancementApplicable to XLEe and XLTe only - Added WebMI 2.0 support
Note – Requires Cscape 10.2 SP2 onwards
Bootloader
XLT/XLTeCSCAN 15.80April 2026Bug FixResolved: Device displayed an exception when an IEC program was configured with a Modbus Master block and an array of structures was enabled.Bootloader
XLT/XLTeCSCAN 15.80April 2026Bug FixResolved: The GE SNP protocol was not working over full-duplex RS-485 communication.
Note –
• Requires SNP DLL v5.02 onwards
• Requires Cscape 10.2 SP2 onwards
Bootloader
XLT/XLTeCSCAN 15.80April 2026Bug FixResolved: The negative Y-axis values were not plotted correctly in trend graphs.Bootloader
XLT/XLTeCSCAN 15.70March 2026EnhancementAdded “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu.
Note: Requires Cscape 10.2 onwards
XLT/XLTeCSCAN 15.70March 2026EnhancementSecurity improvements :
Ethernet ports open only if they are configured in Cscape and downloaded to the device.
XLT/XLTeCSCAN 15.70March 2026EnhancementAdded logging of “return” state alarms, wherein if the alarm was acknowledged, but is still in the alarm state, after the alarm returns to normal, the return was not being logged.
XLT/XLTeCSCAN 15.70March 2026EnhancementAdded System Register bit for the restore operation from logic.
• Restore operation: %SR164.16
XLT/XLTeCSCAN 15.70March 2026EnhancementAdded System Register bit for indicating the status of CAN port
• %SR4.14 indicates a CAN port error and may require a power cycle to recover.
XLT/XLTeCSCAN 15.70March 2026EnhancementThe “Set Local ID” option is supported for both CsCAN and CANOpen network types.
Note: Requires Cscape version 10.1 onwards
XLT/XLTeCSCAN 15.70March 2026Bug FixResolved: Loading a .pgm file did not match the exact model of the OCS, and did not display any error message on the device.
XLT/XLTeCSCAN 15.70March 2026Bug FixEnhanced filename (RM blocks, PGM) support from 8 characters to 47 characters.
XLT/XLTeCSCAN 15.70March 2026Bug FixImproved auto-populate feature in OCSIO
Note: Requires CNX116 / CNX100 FW Version 48 onwards.
XLTe onlyCSCAN 15.70March 2026Bug FixResolved: The Dynamically configured IP address was not editable using the System Menu in Idle mode.
XLTe onlyCSCAN 15.70March 2026Bug FixResolved: (ASCII over TCP/IP) Device status was not displayed correctly after disconnecting and reconnecting the server.
XLTe onlyCSCAN 15.70March 2026Bug FixResolved: Ethernet/IP protocol stops working if the Consumed / Produced configuration exceeds 128 Words.
XLTe onlyCSCAN 15.70March 2026Bug FixResolved the following issues related to WebMI:
• FTP error was being displayed while publishing webpages after a power cycle.
• WebMI pages not loading – Web pages were not being loaded after sign in.

You may also like…