All units feature a built-in logic engine, operator interface, networking and I/O.
Please select the model number from the dropdown to see current stock and pricing.
Current lead time is 2 – 6 weeks.
Logic engine features 1MB of application memory with a 0.02mS/K logic scan. Online Programming Mode (making logic changes on the fly without going thru stop mode) is supported. Operator Interface features include:
Networking features include:
All units feature a microSD slot, supporting at least 32GB.
CONTROLLER MODEL | CONFIGURATION |
---|---|
HE-XPL1E0 | No built-in I/O |
HE-XPL1E2 | 12 DC in, 6 Relay Out, 4 – 12-bit Analog In |
HE-XPL1E3 | 12 DC in, 12 DC Out, 2 – 12-bit Analog In |
HE-XPL1E4 | 24 DC in, 16 DC Out, 2 – 12-bit Analog In |
HE-XPL1E5 | 12 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out |
HE-XPL1E6 | 12 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out |
*Up To six mA/V In, mA/V RTD/Tc, and mA/V Out | |
SPECIAL ORDER (*) | |
Part Number Extension | Description |
-10 | Thermistor option. Add -10 to the part number for Thermistor support for Analog Inputs 1 & 2. Models 2, 3, and 4 only. |
-14 | Thermistor option. Add -14 to the part number for (4) Channel Thermistor support. Model 2 only. |
-44 | SAE J1939 Option. Add -44 part number extension for SAE J1939 communications. CsCAN support is removed. |
-441 | WebMI License Unlimited pre-loaded |
-442 | Enahnced IEC License pre-loaded |
-445 | MQTT License is pre-loaded |
-602 | Screw type I/O terminals. Replaces spring type terminals. Model 6 only. |
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks. | |
For combinations of adder options, please contact the factory – 877.665.5666 |
CONTROLLER | |
Ladder Logic Memory | 2 MB |
Logic Scan Rate | 0.02 mS/K |
Removable Memory | microSD |
Local Comment Storage | Yes |
Floating Point Support | Yes |
AutoTune PID Capable | Yes |
OPERATOR INTERFACE | |
Characters / Pixels | 640x480 |
Display Technology | 5.7” VGA TFT, 450 nits |
Character Height | selectable fonts |
Number of Pages | 1023 |
Fields or Objects per Page | 1023 |
Total Keys | 6 |
Function Keys | 5 |
OEM Faceplate Available | Yes |
I/O | |
Built-in I/O Points | 22-44 |
SmartStix, SmartRail, SmartBlock I/O Support | yes, CsCAN and Ethernet |
Digital Inputs / Outputs, max | 2048 / 2048 |
Analog Inputs / Outputs, max | 512 / 512 |
General Purpose Registers (words) | 50000 |
General Purpose Internal Coils (bits) | 32768 (16384 retentive) |
ETHERNET/INTERNET | |
Ethernet Support | Standard, 1 Port |
Remote Access | WebMI, HTTP or EnvisionRV |
Remote File Access | FTP or EnvisionFX |
IIoT Support | MQTT (Sparkplug) |
SERIAL COMMUNICATIONS | |
Total Active Ports | 3 |
RS-232 Ports / RS-485 Ports | 1 RS-232 & 1 RS-485 on first Modular Jack (MJ1/2); 1 RS-232 or RS-485 on second Modular Jack (MJ3) |
PLC / Drive Protocols | Yes |
RTU / Modbus Master / Slave | Yes |
Serial ASCII In / Out | Yes |
USB Ports (A and Mini-B) | USB 2.0 (480 MHz) for USB FLASH Drives (2TB); USB 2.0 (480 MHZ) Programming & Data Access |
NETWORKING | |
Integrated CAN Networks | 1 |
Supported CAN Networks | CsCAN, CANopen, J1939 and DeviceNet Master (layer 3 as a selectable option) |
Maximum CAN Distance | 500m per segment, 4 segments maximum |
Programming over CAN | CsCAN only |
PHYSICAL SPECIFICATIONS | |
Height | 5.66" / 144 mm |
Width | 7.34" / 187 mm |
Depth | 1.84" / 47 mm |
I/O Module Depth | COM option adds 0.98" / 24.83 mm depth |
OPERATING SPECS & STANDARDS | |
Operating Temperature* | -10 to 60°C |
Humidity (non-condensing) | 5 to 95% |
Product Certifications/Approvals | UL Class 1 Div II, CE |
Environmental Rating | UL Type 1, 3R, 4, 4x, 12, 12k, 13 |
Document | Reference Number | Link to Download | |
---|---|---|---|
SALES LITERATURE | |||
Sales Sheet | HA-369 | ||
Prime Series Accordion | HA-374 | ||
DRAWINGS | 2D ELECTRICAL | 2D MECHANICAL | 3D MECHANICAL |
XL6 Prime Model 0 | |||
XL6 Prime Model 2 | |||
XL6 Prime Model 3 | |||
XL6 Prime Model 4 | |||
XL6 Prime Model 5 | |||
XL6 Prime Model 6 | |||
TECHNICAL DOCUMENTATION | |||
User Manual | MAN1032 | Download | |
Quick Reference Guide | MAN1332 | Download | |
Model 0 Datasheet | MAN1326 | Download | |
Model 2 Datasheet | MAN1327 | Download | |
Model 3 Datasheet | MAN1328 | Download | |
Model 4 Datasheet | MAN1329 | Download | |
Model 5 Datasheet | MAN1330 | Download | |
Model 6 Datasheet | MAN1331 | Download | |
SUPPLEMENTAL | |||
App Guide for Updating Firmware | MAN1362 | Download | |
Firmware Restore Manual | MAN1141 | ||
App Guide for Adding Custom Splash Screen | MAN0990 | ||
Thermistor Supplement | SUP0797 | ||
Ethernet Supplement Manual | SUP0740 | Download |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types. Note: This requires Cscape 10 SP1 onwards. | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | ||
Prime XL15 | CSCAN 17.04 | September 2024 | Bug Fix | Resolved: USB Type C communication not working on XL15 Prime model. | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
Prime XL15 only | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved possible condition where device could get stuck on splash screen after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved %SR181 and %SR182 not updating for Unacknowledged and Active alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved an unintended condition in which the display could be kept on by a mini-USB connection even when 24V supply to the controller was removed. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved title bar of password object showing nonsense when Unicode fonts were created. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved WebMI alarm history page not listing the RTN alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CANOpen blocks not working when CAN1 port was configured as CANOpen and CAN2 port as J1939. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new OCSIO modules - DQM606, DIM610 and CNX100; NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards. %SR104 – 32bit %SR for storing password of program which is currently running.%SR106 – 32bit %SR for storing password of program which is being loaded | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added Ethernet dongle status register - %S15 (10185) NOTE: When the Ethernet dongle is connected, %S15 bit will be enabled, once it is removed, %S15 bit will be disabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Feature request to add a reset bit for EtherNet/IP Server. (8633) NOTE: SR156.3 for Ethernet/Ip protocol Lan1 reset. SR153.3 for Ethernet/Ip protocol Lan2 reset. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein MQTT NBIRTH/NDEATH packets were causing loss of communications (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spams (9105) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unit was not showing negative value when CPU temperature was below Zero deg C and min/max value would wrap around (8587) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was working (10016) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured (8765) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device restart to resume communications (8635) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue when the X5 Prime was reporting bad clock/battery and would sometimes default the clock. (9903) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue where audio was not functional when 105 IO card was being used on XL7/XL10 Prime models. This also solves slow boot issue. (7530) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.22 | March 2023 | Bug Fix | Resolved issue where XL Prime units could drop out of RUN mode due to a logic error. (9527) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | OCSIO Support has been added. This requires Cscape 9.90 SP8 onwards. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Improved upgrade procedure for non-bootable microSD card option. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Added "Replace System Graphics" support in System recovery screen for customizing slide key* and splash screen. *Slide key customization applicable to XLW Prime and X5 Prime only. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Bug Fix | Resolved touch and bootup issue at low temperature. (8929) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.16 | October 2022 | Bug Fix | Fixed issue where incorrect data was being populated into the upper word for High Speed Counter inputs. (8706) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | Support added for LAN2 when using included USB Dongle for XL7 and XL10 Prime models only. Requires Cscape 9.9 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | New X5 Prime model has been added. NOTE: Requires Cscape 9.90 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Resolved issue when conversion blocks were working for ODD register numbers only and was failing EVEN register number in Register-Based Advanced Ladder. (6233) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Serial Modbus communication has been improved for higher baud rates. (7674) | Bootloader, Cscape 9.90 SP8 or higher |