Call Us: 877-665-5666

XL6 Prime

Build to order – Standard lead times are 2-6 weeks.

All units feature a built-in logic engine, operator interface, networking and I/O.

Please select the model number from the dropdown to see current stock and pricing.

Current lead time is 2 – 6 weeks.

                       

HORNER APP

The Horner App is the first automation app to give customers the ability to access all WebOCS enabled controllers with their iOS or Android phone or tablet.

 

 

SKU: N/A Category:

Description

Logic engine features 1MB of application memory with a 0.02mS/K logic scan. Online Programming Mode (making logic changes on the fly without going thru stop mode) is supported. Operator Interface features include:

  • 640×480 LCD TFT color graphics display with a high resolution resistive touchscreen
  • 4 function keys and a system key
  • USB 2.0 On-the-Go port (mini-B 5pin) is available for programming
  • USB 2.0 Host port (A) is available for exchanging files with USB FLASH drives
  • Two (2) RS-232 and one (1) RS-485 port support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols

Networking features include:

  • Built-in 10/100 Ethernet port
  • Integrated CsCAN port

All units feature a microSD slot, supporting at least 32GB.

Model Lineup

CONTROLLER MODELCONFIGURATION
HE-XPL1E0No built-in I/O
HE-XPL1E212 DC in, 6 Relay Out, 4 – 12-bit Analog In
HE-XPL1E312 DC in, 12 DC Out, 2 – 12-bit Analog In
HE-XPL1E424 DC in, 16 DC Out, 2 – 12-bit Analog In
HE-XPL1E512 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out
HE-XPL1E612 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out
*Up To six mA/V In, mA/V RTD/Tc, and mA/V Out
SPECIAL ORDER (*)
Part Number ExtensionDescription
-10 Thermistor option. Add -10 to the part number for Thermistor support for Analog Inputs 1 & 2. Models 2, 3, and 4 only.
-14 Thermistor option. Add -14 to the part number for (4) Channel Thermistor support. Model 2 only.
-44SAE J1939 Option. Add -44 part number extension for SAE J1939 communications. CsCAN support is removed.
-441WebMI License Unlimited pre-loaded
-442Enahnced IEC License pre-loaded
-445MQTT License is pre-loaded
-602Screw type I/O terminals. Replaces spring type terminals. Model 6 only.
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks.
For combinations of adder options, please contact the factory – 877.665.5666

Specifications

CONTROLLER
Ladder Logic Memory2 MB
Logic Scan Rate0.02 mS/K
Removable MemorymicroSD
Local Comment StorageYes
Floating Point SupportYes
AutoTune PID CapableYes
OPERATOR INTERFACE
Characters / Pixels640x480 (450 nit typical)
Display Technology5.7” VGA TFT
Character Heightselectable fonts
Number of Pages1023
Fields or Objects per Page1023
Total Keys6
Function Keys5
OEM Faceplate AvailableYes
I/O
Built-in I/O Points22-44
SmartStix, SmartRail, SmartBlock I/O Supportyes, CsCAN and Ethernet
Digital Inputs / Outputs, max2048 / 2048
Analog Inputs / Outputs, max512 / 512
General Purpose Registers (words)50000
General Purpose Internal Coils (bits)32768 (16384 retentive)
ETHERNET/INTERNET
Ethernet SupportStandard, 1 Port
Remote AccessWebMI, HTTP or EnvisionRV
Remote File AccessFTP or EnvisionFX
IIoT SupportMQTT (Sparkplug)
SERIAL COMMUNICATIONS
Total Active Ports3
RS-232 Ports / RS-485 Ports1 RS-232 & 1 RS-485 on first Modular Jack (MJ1/2); 1 RS-232 or RS-485 on second Modular Jack (MJ3)
PLC / Drive ProtocolsYes
RTU / Modbus Master / SlaveYes
Serial ASCII In / OutYes
USB Ports (A and Mini-B)USB 2.0 (480 MHz) for USB FLASH Drives (2TB); USB 2.0 (480 MHZ) Programming & Data Access
NETWORKING
Integrated CAN Networks1
Supported CAN NetworksCsCAN, CANopen, J1939 and DeviceNet Master (layer 3 as a selectable option)
Maximum CAN Distance500m per segment, 4 segments maximum
Programming over CAN       CsCAN only
PHYSICAL SPECIFICATIONS
Height5.66" / 144 mm
Width7.34" / 187 mm
Depth1.84" / 47 mm
I/O Module DepthCOM option adds 0.98" / 24.83 mm depth
OPERATING SPECS & STANDARDS
Operating Temperature*-10 to 60°C
Humidity (non-condensing)5 to 95%
Product Certifications/ApprovalsUL Class 1 Div II, CE
Environmental RatingUL Type 1, 3R, 4, 4x, 12, 12k, 13

Documentations & Resources

DocumentReference NumberLink to Download
SALES LITERATURE
Sales SheetHA-369
Prime Series AccordionHA-374
DRAWINGS
2D Electrical Model 0
2D Mechanical Model 0
3D Mechanical Model 0
2D Electrical Model 2
2D Mechanical Model 2
3D Mechanical Model 2
2D Electrical Model 3
2D Mechanical Model 3
3D Mechanical Model 3
2D Electrical Model 4
2D Mechanical Model 4
3D Mechanical Model 4
2D Electrical Model 5
2D Mechanical Model 5
3D Mechanical Model 5
2D Electrical Model 6
2D Mechanical Model 6
3D Mechanical Model 6
TECHNICAL DOCUMENTATION
User ManualMAN1032Download
Quick Reference GuideMAN1332Download
Model 0 DatasheetMAN1326Download
Model 2 DatasheetMAN1327Download
Model 3 DatasheetMAN1328Download
Model 4 DatasheetMAN1329Download
Model 5 DatasheetMAN1330Download
Model 6 DatasheetMAN1331Download
SUPPLEMENTAL
App Guide for Updating FirmwareMAN1362Download
Firmware Restore ManualMAN1141
App Guide for Adding Custom Splash ScreenMAN0990
Thermistor SupplementSUP0797
Ethernet Supplement ManualSUP0740Download

Certifications

Certification TypeDownload Certificate
CE Declaration of Conformity
ISO 9001: 2015

Firmware Review Notes

PRODUCTVERSIONRELEASE DATETYPEDETAILSREQUIREMENTS
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023EnhancementAdded new OCSIO modules - DQM606, DIM610 and CNX100; NOTE: CNX100 requires Cscape 9.90 SP10 onwardsBootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023EnhancementAdded new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards. %SR104 – 32bit %SR for storing password of program which is currently running.%SR106 – 32bit %SR for storing password of program which is being loadedBootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023EnhancementAdded Ethernet dongle status register - %S15 (10185) NOTE: When the Ethernet dongle is connected, %S15 bit will be enabled, once it is removed, %S15 bit will be disabled.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023EnhancementFeature request to add a reset bit for EtherNet/IP Server. (8633) NOTE: SR156.3 for Ethernet/Ip protocol Lan1 reset. SR153.3 for Ethernet/Ip protocol Lan2 reset.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023Bug FixResolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040)Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023Bug FixResolved issue wherein MQTT NBIRTH/NDEATH packets were causing loss of communications (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023Bug FixAdded time zone information in email header to avoid email sent from OCS being treated as spams (9105)Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023Bug FixResolved issue wherein unit was not showing negative value when CPU temperature was below Zero deg C and min/max value would wrap around (8587)Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023Bug FixResolved issue wherein only limited number of users configured in user security configuration was working (10016)Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023Bug FixResolved issue wherein device would PING for an invalid subnet mask configured (8765)Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.30July 2023Bug FixResolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device restart to resume communications (8635)Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.28May 2023Bug FixResolved issue when the X5 Prime was reporting bad clock/battery and would sometimes default the clock. (9903)Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.28May 2023Bug FixResolved issue where audio was not functional when 105 IO card was being used on XL7/XL10 Prime models. This also solves slow boot issue. (7530)Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.22March 2023Bug FixResolved issue where XL Prime units could drop out of RUN mode due to a logic error. (9527)Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.20March 2023EnhancementOCSIO Support has been added. This requires Cscape 9.90 SP8 onwards.Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.20March 2023EnhancementImproved upgrade procedure for non-bootable microSD card option.Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.20March 2023EnhancementAdded "Replace System Graphics" support in System recovery screen for customizing slide key* and splash screen. *Slide key customization applicable to XLW Prime and X5 Prime only.Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.20March 2023Bug FixResolved touch and bootup issue at low temperature. (8929)Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.16October 2022Bug FixFixed issue where incorrect data was being populated into the upper word for High Speed Counter inputs. (8706)Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.14September 2022EnhancementSupport added for LAN2 when using included USB Dongle for XL7 and XL10 Prime models only. Requires Cscape 9.9 SP8 or higher.Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.14September 2022EnhancementNew X5 Prime model has been added. NOTE: Requires Cscape 9.90 SP8 or higher.Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.14September 2022Bug FixResolved issue when conversion blocks were working for ODD register numbers only and was failing EVEN register number in Register-Based Advanced Ladder. (6233)Bootloader, Cscape 9.90 SP8 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.14September 2022Bug FixSerial Modbus communication has been improved for higher baud rates. (7674)Bootloader, Cscape 9.90 SP8 or higher

Videos

You may also like…

Title

Go to Top