| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added WebMI 2.0 support
Note – Requires Cscape 10.2 SP1 onwards | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support for ASCII username and password
Note – Requires Cscape 10.2 SP1 onwards | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Implemented new retentive timer and counter blocks that retain accumulator values after a power cycle
Note –
• Applicable to Enhanced IEC only
• Requires Cscape 10.2 SP1 onwards | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support to HSC840 and NTC800 OCS-I/O modules
Note – Requires Cscape 10.2 SP1 onwards | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added “Use as Default Gateway” option
Note – Requires Cscape 10.2 SP1 onwards | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein email stopped working when used Secomea Email Relay on port 25 without authentication | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the device displayed an exception when the program was configured with a Modbus Master block and array of structures was enabled
Note – Applicable to IEC and Enhanced IEC blocks | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the ASCII TCP/IP Server protocol did not function when configured with registers beyond %R10000 | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where Ethernet status TX/RX bits were not shown as active when MQTT and OCS360 were enabled | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where a .PGM file placed inside a folder was not loading | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication
Note –
• Requires SNP dll v5.02 onwards
• Requires Cscape 10.2 SP1 onwards | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein the device displayed system exception when devices with dual ports were configured with downloadable protocols having large scan list entries for two or more ports | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the LAN configuration status read a value of zero when configured with registers beyond %R8193 | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue that caused the device to enter Idle mode after downloading a CANOpen Blocks program with the “Array of Structures” option enabled | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu.
Note : Requires Cscape 10.2 onwards | Requires Cscape 10.2 onward |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Security Improvement
Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Enhanced IEC only
Resolved - Clearing alarms from the alarm history object was giving a system exception. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol:
• Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program.
• Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program.
• Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled.
Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The device displayed a system exception when triggered by MQTT without running a broker. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program.
• Triggering an alarm was displaying a different alarm on the device.
• Triggering an alarm was displaying an alarm message multiple times on the device. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating.
Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4. | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O.
Note: Requires CNX116 / CNX100 firmware version 48 onwards. | |
| Prime XL15 | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP
• SR235.1 - DHCP1 (0 - Disable and 1 - Enable)
• SR235.2 - DHCP2 (0 - Disable and 1 - Enable)
Note: Requires Cscape 10.1 SP1 onwards. | |
| Prime XL15 | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | |
| Prime XL15 | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | |
| Prime XL15 | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | |
| Prime XL15 | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | |
| Prime XL15 | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | |
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added: OCS360 support.
Note(s)
• Requires Cscape version 10.1 onwards
• OCS360 status information is now consistent with MQTT. | |
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming.
Note: Requires Cscape version 10.1 onwards | |
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added: System Register bit for System Menu access.
Note: Requires Cscape version 10.1 onwards. | |
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | |
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types.
Note: Requires Cscape version 10.1 onwards | |
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added support to apply license through System Register and System Menu.
Note: Requires Cscape version 10.1 onwards | |
| Prime XL15 | 17.10 | February 2025 | Bug Fix | Resolved: Bitmaps were not displayed on the device. | |
| Prime XL15 | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | |
| Prime XL15 | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | |
| Prime XL15 | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | |
| Prime XL15 | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types.
Note: This requires Cscape 10 SP1 onwards. | |
| Prime XL15 | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug:
• Increased store-and-forward queue length from 256 to 1024
• Increased maximum publish topic size to 256 and 128 metrics per topic
• Added Auto Reconnect enable/disable with configurable timeout
• Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | |
| Prime XL15 | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0
Note
• When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0.
• When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | |
| Prime XL15 | CSCAN 17.04 | September 2024 | Bug Fix | Resolved: USB Type C communication not working on XL15 Prime model. | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder
Note: This requires Cscape version 10 onwards | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address
• Resolved: NTP server was skipping a day on new year’s if it was a leap year | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | |
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | |