Call Us: 877-665-5666

XL10 Prime

Price range: $4,022.00 through $4,669.00

1 in stock (can be backordered)

All units feature a built-in logic engine, operator interface, networking and I/O.

Please select the model number from the dropdown to see current stock and pricing.

Current lead time is 2 – 6 weeks.

 

This controller is BABAA Compliant

SKU: N/A Category:

Description

XL10 Prime

XL10 Prime – Logic engine features 2MB of application memory with a 0.02mS/K logic scan. Online Programming Mode (making logic changes on the fly without going thru stop mode) is supported.

Operator Interface features include:

  • 640×480 LCD TFT color graphics display with a high resolution resistive touchscreen
  • 7 function keys and a system key
  • USB 2.0 On-the-Go port (mini-B 5pin) is available for programming
  • USB 2.0 Host port (A) is available for exchanging files with USB FLASH drives
  • Two (2) RS-232/485 ports support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols

XL10 Prime Networking features include:

  • (2) built-in 10/100 Ethernet port
  • (2) integrated CAN ports that support CsCAN and either CANopen, J1939, or DeviceNet Scanner simultaneously

All units feature a microSD slot, supporting at least 32GB.

Model Lineup

CONTROLLER MODELCONFIGURATION
HE-XPV1E0No built-in I/O
HE-XPV1E212 DC in, 6 Relay Out, 4 – 12-bit Analog In
HE-XPV1E312 DC in, 12 DC Out, 2 – 12-bit Analog In
HE-XPV1E424 DC in, 16 DC Out, 2 – 12-bit Analog In
HE-XPV1E512 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out
HE-XPV1E612 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out
*Up To six mA/V In, mA/V RTD/Tc, and mA/V Out
SPECIAL ORDER (*)
Part Number ExtensionDescription
-10 Thermistor option. Add -10 to the part number for Thermistor support for Analog Inputs 1 & 2. Models 2, 3, and 4 only.
-14Thermistor option. Add -14 to the part number for (4) Channel Thermistor support. Model 2 only.
-441WebMI License Unlimited pre-loaded
-442Enhanced IEC License pre-loaded
-445MQTT License pre-loaded
-602Screw type I/O terminals. Replaces spring type terminals. Model 6 only.
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks.
For combinations of adder options, please contact the factory – 877.665.5666

Specifications

CONTROLLER
Ladder Logic Memory2 MB
Logic Scan Rate0.02 mS/K
Removable MemorymicroSD
Local Comment StorageYes
Floating Point SupportYes
AutoTune PID CapableYes
OPERATOR INTERFACE
Characters / Pixels640x480
Display Technology10.4” VGA TFT Color, 550 nits
Character Heightselectable fonts
Number of Pages1023
Fields or Objects per Page1023
Total Keys8
Function Keys7
OEM Faceplate AvailableYes
I/O
Built-in I/O Points22-44
SmartStix, SmartRail, SmartBlock I/O Supportyes, CsCAN and Ethernet
Digital Inputs / Outputs, max2048 / 2048
Analog Inputs / Outputs, max512 / 512
General Purpose Registers (words)50000
General Purpose Internal Coils (bits)32768 (16384 retentive)
ETHERNET/INTERNET
LAN Ports2
Factory ProtocolsEthernet IP (Server & HMI), Modbus TCP (Client/Server), BACnet IP (Server), EGD
IIoT & Remote AccessMQTT Sparkplug*, Horner OC360 Cloud Service*, WebMI via HTML5, EnvisionRV
Other ProtocolsSMTP(Client), NTP (Client), FTP (Server)
*MQTT Sparkplug & WebMI require a one-time upgrade. OCS360 is an annual subscription service.
SERIAL COMMUNICATIONS
Total Active Ports3
RS-232 Ports / RS-485 PortsRS-232 & RS-485; RS-232 / RS-485
PLC / Drive ProtocolsYes
RTU / Modbus Master / SlaveYes
Serial ASCII In / OutYes
USB Ports (A and Mini-B)Yes
NETWORKING
Integrated CAN Networks2
Supported CAN NetworksCsCAN, CANopen, J1939 and DeviceNet Master (layer 3 as a selectable option)
Maximum CAN Distance500m per segment, 4 segments maximum
Programming over CAN       CsCAN only
Supported CAN ProtocolsCsCAN plus one of the following: CANopen, DeviceNet Master (layer-3 as a selectable option - one only), SAE J1939
PHYSICAL SPECIFICATIONS
Height9.08" / 231 mm
Width11.94" / 304 mm
Depth2.43" / 62 mm
I/O Module DepthCOM option adds 1.08" / 27.40 mm
OPERATING SPECS & STANDARDS
Operating Temperature-10 to 60°C
Storage Temperature-20°C to +60°C
Humidity (non-condensing)5 to 95%
Product Certifications/ApprovalsUL Class I Div II, CE
Environmental RatingUL Type 1, 3R, 4, 4x, 12, 12k, 13

Documentation & Resources

DocumentReference NumberLink to DownloadLink to Download
SALES LITERATURE
Prime Series AccordionHA-374
XL10 PRIME DRAWINGS 2D ELECTRICAL2D MECHANICAL3D MECHANICAL
XL10 Prime Model 0
XL10 Prime Model 2
XL10 Prime Model 3
XL10 Prime Model 4
XL10 Prime Model 5
XL10 Prime Model 6
TECHNICAL DOCUMENTATION
User ManualMAN1029Download
Quick Reference GuideMAN1310Download
Model 0 DatasheetMAN1312Download
Model 2 DatasheetMAN1313Download
Model 3 DatasheetMAN1314Download
Model 4 DatasheetMAN1315Download
Model 5 DatasheetMAN1316Download
Model 6 DatasheetMAN1317Download
SUPPLEMENTAL
App Guide for Updating FirmwareMAN1362Download
Firmware Restore GuideMAN1141
App Guide for Adding Custom Splash ScreenMAN0990
Thermistor SupplementSUP0797
Ethernet Supplement ManualSUP0740Download
Cutout Template SheetSUP1551

Certifications

Certification TypeDownload Certificate
BABAA - Build America, Buy America Act
CE Declaration of Conformity
ISO 9001: 2015

Firmware Review Notes

PRODUCTVERSIONRELEASE DATETYPEDETAILSREQUIREMENTS
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.32March 3, 2026Bug FixResolved: Device boot-up issue at cold temperatures.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025EnhancementAdded “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu.
Note : Requires Cscape 10.2 onwards
Requires Cscape 10.2 onward
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025EnhancementAdded OCS360 System Menu Pages
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025EnhancementEnhancements were made in the boot-up message by displaying the boot-up messages in a single screen.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025EnhancementSecurity Improvement
Ethernet ports are open only if they are configured in Cscape and downloaded to the device.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025EnhancementAdded logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025EnhancementAdded system register bit for restore operation from logic: %SR164.16 – Restore operation
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved – The dynamically configured IP address was not editable using the System Menu in Idle mode.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixEnhanced IEC only
Resolved - Clearing alarms from the alarm history object was giving a system exception.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved the following issues related to the CANOpen protocol:
• Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program.
• Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program.
• Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled.
 Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved – The device displayed a system exception when triggered by MQTT without running a broker.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program.
• Triggering an alarm was displaying a different alarm on the device.
• Triggering an alarm was displaying an alarm message multiple times on the device.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixResolved - Analog Input values were fluctuating.
Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4.
Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL1517.30October 2025Bug FixImproved auto-populate feature in OCS-I/O.
Note: Requires CNX116 / CNX100 firmware version 48 onwards.
Prime X5, XL4, XL6, XLW, XL7, XL1017.20May 2025EnhancementAdded system register support to enable and disable DHCP
• SR235.1 - DHCP1 (0 - Disable and 1 - Enable)
• SR235.2 - DHCP2 (0 - Disable and 1 - Enable)
Note: Requires Cscape 10.1 SP1 onwards.
Prime X5, XL4, XL6, XLW, XL7, XL1017.20May 2025EnhancementAdded security enhancement for adding a device in OCS360.
Prime X5, XL4, XL6, XLW, XL7, XL1017.20May 2025Bug FixResolved: The screen capture for video streaming was not working.
Prime X5, XL4, XL6, XLW, XL7, XL1017.20May 2025Bug FixResolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program.
Prime X5, XL4, XL6, XLW, XL7, XL1017.20May 2025Bug FixResolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name.
Prime X5, XL4, XL6, XLW, XL7, XL1017.20May 2025Bug FixResolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected.
Prime X5, XL4, XL6, XLW, XL7, XL1017.10February 2025EnhancementAdded: OCS360 support.
Note(s)
• Requires Cscape version 10.1 onwards
• OCS360 status information is now consistent with MQTT.
Prime X5, XL4, XL6, XLW, XL7, XL1017.10February 2025EnhancementAdded: Support for multiple USB video streaming.
Note: Requires Cscape version 10.1 onwards
Prime X5, XL4, XL6, XLW, XL7, XL1017.10February 2025EnhancementAdded: System Register bit for System Menu access.
Note: Requires Cscape version 10.1 onwards.
Prime X5, XL4, XL6, XLW, XL7, XL1017.10February 2025EnhancementAdded Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device.
Prime X5, XL4, XL6, XLW, XL7, XL1017.10February 2025EnhancementAdded: “Set Local ID” option is supported for both CsCAN and CANOpen network types.
Note: Requires Cscape version 10.1 onwards
Prime X5, XL4, XL6, XLW, XL7, XL1017.10February 2025EnhancementAdded support to apply license through System Register and System Menu.
Note: Requires Cscape version 10.1 onwards
Prime X5, XL4, XL6, XLW, XL7, XL1017.10February 2025Bug FixResolved: Bitmaps were not displayed on the device.
Prime X5, XL4, XL6, XLW, XL7, XL1017.10February 2025Bug FixResolved: The device was not sending the NMT start command to CANOpen devices after powering up.
Prime X5, XL4, XL6, XLW, XL7, XL1017.10February 2025Bug FixResolved: Forcing was not working when the unit was placed in debug mode.
Prime X5, XL4, XL6, XLW, XL7, XL1017.06November 2024EnhancementAdded XL10W prime support.
Prime X5, XL4, XL6, XLW, XL7, XL1017.06November 2024EnhancementAdded new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types.
Note: This requires Cscape 10 SP1 onwards.
Prime X5, XL4, XL6, XLW, XL7, XL1017.06November 2024EnhancementThe following enhancements have been added to MQTT Sparkplug:
• Increased store-and-forward queue length from 256 to 1024
• Increased maximum publish topic size to 256 and 128 metrics per topic
• Added Auto Reconnect enable/disable with configurable timeout
• Added the ability to choose if a metric should be buffered or not in a store-and-forward situation
Prime X5, XL4, XL6, XLW, XL7, XL1017.06November 2024Bug FixResolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0
Note
• When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0.
• When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download.
Prime X5, XL4, XL6, XLW, XL7, XL10CSCAN 17.02August 2024EnhancementRetain variable support added for variable-based advanced ladder
Note: This requires Cscape version 10 onwards
Prime X5, XL4, XL6, XLW, XL7, XL10CSCAN 17.02August 2024Bug FixFixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language
Prime X5, XL4, XL6, XLW, XL7, XL10CSCAN 17.02August 2024Bug FixResolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program
Prime X5, XL4, XL6, XLW, XL7, XL10CSCAN 17.02August 2024Bug FixResolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks
Prime X5, XL4, XL6, XLW, XL7, XL10CSCAN 17.02August 2024Bug Fix• Resolved: NTP was not working when configured with IP address
• Resolved: NTP server was skipping a day on new year’s if it was a leap year
Prime X5, XL4, XL6, XLW, XL7, XL10CSCAN 17.02August 2024Bug FixResolved: Performance of the device slows down and scan rate increases at higher temperatures
Prime X5, XL4, XL6, XLW, XL7, XL10CSCAN 17.02August 2024Bug FixResolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled
Prime X5, XL4, XL6, XLW, XL7, XL10CSCAN 17.02August 2024Bug FixResolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements
Prime X5, XL4, XL6, XLW, XL7, XL10CSCAN 17.02August 2024Bug FixResolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024EnhancementAdded build version and firmware version in system menu | view status.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024EnhancementAdded limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media blockBootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixAdded support for using external modem as client with modem blocks.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved Modbus Client sending zero value when Holding Register was not zero.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved the following issues: • UTC time not being updated when downloaded from Cscape.
• Default audio volume was too low when compared with previous firmware versions.
Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language.
Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved CAN2 stops working after several power cycles.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved possible condition where device could get stuck on splash screen after several power cycles.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved %SR181 and %SR182 not updating for Unacknowledged and Active alarms.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved an unintended condition in which the display could be kept on by a mini-USB connection even when 24V supply to the controller was removed.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved title bar of password object showing nonsense when Unicode fonts were created.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved WebMI alarm history page not listing the RTN alarms.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved CANOpen blocks not working when CAN1 port was configured as CANOpen and CAN2 port as J1939.Bootloader, Cscape 9.90 SP9 or higher
Prime XL4, XL6, XLW, XL7, XL10, X5CSCAN 16.32April 2024Bug FixResolved ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller.Bootloader, Cscape 9.90 SP9 or higher