Call Us: 877-665-5666

X5

19 in stock (can be backordered)

The X5 is the first product of the streamlined Micro OCS Series of embedded I/O controllers. All units feature a built-in logic engine, operator interface, networking and I/O.

Current lead time is up to 6 weeks.

HORNER APP

The Horner App is the first automation app to give customers the ability to access all WebOCS enabled controllers with their iOS or Android phone or tablet.

 

 

 

X5 Controller 4.3″, 4 DC In, 4 DC Out, 4 Analog In (mA/V)

Please login to see price/buy item.
SKU: HE-X5 Category:

Description

WIDE ASPECT COLOR TOUCHSCREEN
The X5 really packs a big picture into an overall small package. With just a 4.6” x 3.5” cutout, this 4.3” wide aspect screen is very friendly, intuitive, and clear. By incorporating our hidden soft key technology, you can use the entire screen to illustrate your specific applications.

STREAMLINED I/O
In an effort to make implementing Horner OCS controllers as seamless and user-friendly as possible, we have selected a streamlined set of on-board I/O. 4 digital inputs, 4 digital outputs, and 4 analog inputs make automating your applications, and your organization, as simple as the push of a (virtual) button.

PERFORMANCE
When it comes to speed, resolution, and technical capabilities, the X5 is leading the way. We have developed some entirely new design techniques, a suite of capabilities similar to our more established XL line of products, and unprecedented acceptance across an array of commercial and industrial applications. In the market of fixed I/O, web-compatible controllers, the X5 is unmatched.

Model Lineup

Digital I/O4 Inputs, 4 Outputs
High Speed In4 @ 500kHz (4 signals)
High Speed Out2 PWM or Stepper Out
Analog In4 12-bit
Analog Out
Temperature In
Ethernet1 Port
SPECIAL ORDER (*)
Part Number ExtensionDescription
-441WebMI License Unlimited pre-loaded
-442Enhanced IEC License pre-loaded
-445MQTT License is pre-loaded
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks.
For combinations of adder options, please contact the factory – 877.665.5666

Specifications

CONTROLLER
Ladder Logic Memory1 MB
Logic Scan Rate0.04 mS/K
Removable MemorymicroSD
Local Comment StorageYes
Floating Point SupportYes
AutoTune PID CapableYes
OPERATOR INTERFACE INTERFACE
Characters / Pixels480 x 272
Display Technology4.3" TFT Color
Character HeightSelectable Fonts
Number of Pages1023
Fields or Objects per Page1023
Total Keys5 (on screen)
Function Keys4 (on screen)
OEM Faceplate AvailableYes
I/O
Built-in I/O Points12
SmartStix, SmartRail, SmartBlock I/O Supportyes, CsCAN and Ethernet
Digital Inputs / Outputs, max2048 / 2048
Analog Inputs / Outputs, max512 / 512
General Purpose Registers (words)8,912 (1,024 retentive)
General Purpose Internal Coils (bits)4,096 (2,048 retentive)
ETHERNET/INTERNET
Ethernet Supportstandard
Remote AccessWebMI, HTTP or EnvisionRV
Remote File AccessFTP or EnvisionFX
IIoT Support MQTT (Sparkplug)
SERIAL COMMUNICATIONS
Total Active Ports2
RS-232 Ports / RS-485 PortsRS-232 / RS-485 (1 of each)
PLC / Drive ProtocolsYes
RTU / Modbus Master / SlaveYes
Serial ASCII In / OutYes
USB Ports (A and Mini-B)Yes
NETWORKING
Integrated CAN NetworksStandard
Supported CAN NetworksCsCAN, CANopen (firmware change), DeviceNet Master (contact factory), SAE J1939 (contact factory)
Maximum CAN Distance1,640 ft.
Programming over CAN Yes
PHYSICAL SPECIFICATIONS
Height3.79″ / 96.27 mm
Width4.92″ / 124.97 mm
Total Depth1.4″ / 35.8 mm
OPERATING SPECIFICATIONS & STANDARDS
Operating Temperature-10 to 60°C
Humidity (non-condensing)5 to 95%
Product CertificationsCE, C’, UL Class 1 Div II
Environmental RatingIP66, UL Type 3R, 4, 4x, 12, 12k, 13

Documentation & Resources

X5 DocumentsReference NumberLink to Download
SALES LITERATURE
X5 Sales SheetHA-209
OCS Comparison GuideHA-294
TECHNICAL DOCUMENTATION
X5 User ManualMAN1039Download
X5 DatasheetMAN1040Download
X5 Quick Reference GuideMAN1210Download
DRAWINGS2D ELECTRICAL2D MECHANICAL3D MECHANICAL
HE-X5
HE-X5 Overlay (DWG / PDF)
SUPPLEMENTAL
App Guide for Updating FirmwareMAN1011Download
Firmware Restore ManualMAN1141
App Guide for Adding Custom Splash ScreenMAN0990
Ethernet Supplement ManualSUP0740Download

Certifications

Certification TypeDownload Certificate
UL
CE Declaration of Conformity
ISO 9001: 2015
Lithium Battery Test Summary

Videos

For more X5 and other videos, please visit our YouTube Channel

Firmware Review Notes

PRODUCTVERSIONRELEASE DATETYPEDETAILSREQUIREMENTS
X515.649/18/23EnhancementAdded support for OCS-I/O (CNX100) modules.Bootloader, Cscape 9.90 SP10
X515.649/18/23Bug FixResolved issue wherein device would PING for an invalid subnet mask configured. (8765)Bootloader, Cscape 9.90 SP10
X515.649/18/23Bug FixResolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC onlyBootloader, Cscape 9.90 SP10
X515.649/18/23Bug FixResolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212)Bootloader, Cscape 9.90 SP10
X515.649/18/23Bug FixResolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843)Bootloader, Cscape 9.90 SP10
X515.649/18/23Bug FixResolved issue wherein only limited number of users configured in user security configuration were working. (10016)Bootloader, Cscape 9.90 SP10
Download >Download Firmware 15.64 Release Notes
X515.625/8/23EnhancementOCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmwareBootloader
X515.625/8/23EnhancementAdded new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345)
NOTE: This requires Cscape 9.90 SP9 onwards
%SR104–32bit %SR for storing password of program which is currently running
%SR106–32bit %SR for storing password of program which is being loaded
Bootloader
X515.625/8/23Bug FixResolved ethernet port lock up issues. (8464)Bootloader
X515.625/8/23Bug FixResolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards.Bootloader
X515.625/8/23Bug FixResolved device was displaying exception when used Copy_CF block – IEC issue. (7631)Bootloader
X515.625/8/23Bug FixResolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443)Bootloader
X515.625/8/23Bug FixResolved Q1 output was not going TRUE after online change issue. (8713)Bootloader
X515.625/8/23Bug FixResolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029)Bootloader
X515.625/8/23Bug FixResolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995)Bootloader
X515.625/8/23Bug FixResolved alarm history was not listing all alarms on webpages issue. (1643)Bootloader
X515.625/8/23Bug FixResolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642)
NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets
Bootloader
X515.625/8/23Bug FixResolved loss of communication issues with BACNet MSTP protocol for X5. (8881)
NOTE: X5 only.
Bootloader
X515.625/8/23Bug FixResolved communication issues with ethernet SmartRail bases. (8625)Bootloader
X515.625/8/23Bug FixResolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458)Bootloader
X515.625/8/23Bug FixResolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045)Bootloader
X515.625/8/23Bug FixAdded time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105)Bootloader
X515.625/8/23Bug FixResolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843)
NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication.
Bootloader
Download >Download Firmware 15.62 Release Notes
X5CSCAN 15.60November 2022EnhancementAdded register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143)Bootloader
X5CSCAN 15.60November 2022EnhancementOCS-I/O Support. Requires Cscape 9.90 SP8 onwards.Bootloader
X5CSCAN 15.60November 2022EnhancementModification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623)Bootloader
X5CSCAN 15.60November 2022Bug FixResolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233)Bootloader
X5CSCAN 15.60November 2022Bug FixResolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508)Bootloader
X5CSCAN 15.60November 2022Bug FixResolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461)Bootloader
X5Download Firmware 15.60 Release Notes
X5CSCAN 15.54March 2022EnhancementTime-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398)Bootloader
X5CSCAN 15.54March 2022Bug FixIn the Report Editor, an extra character was being added to the end of the report before the Carriage Return, resulting in certain printers not to work as expected. (4699)Bootloader
X5CSCAN 15.54March 2022Bug FixReal to DINT conversion was giving incorrect result for some values. (5314)Bootloader
X5CSCAN 15.54March 2022Bug FixResolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591)Bootloader
X5CSCAN 15.54March 2022Bug FixRadio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards.Bootloader
X5CSCAN 15.54March 2022Bug FixF-keys tied to switch screen coils would sometimes remain held during the screen switch until pressed again. (4668) NOTE: Applies to EXL6, EXLW and X5 only.Bootloader
X5CSCAN 15.54March 2022Bug FixModbusTCP communication was not starting until Reacquire Time has timed out. (5042)Bootloader
X5CSCAN 15.54March 2022Bug FixModbus TCP communication would stop due to DHCP lease time getting expired. (6101)Bootloader
X5CSCAN 15.54March 2022Bug FixUnit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700)Bootloader
X5CSCAN 15.54March 2022Bug FixWebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429)Bootloader
X5CSCAN 15.54March 2022Bug FixRemove all options for firmware upgrade except "Install Bootloader". (6333)Bootloader
X5CSCAN 15.54March 2022Bug Fixa. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398)Bootloader
X5Download Firmware 15.54 Release Notes
X5CSCAN 15.52May 2021EnhancementAdded Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2:
%SR156.1 - EGD for LAN1
%SR156.2 - Modbus TCP Slave for LAN1
%SR156.4 - FTP for LAN1
%SR156.5 - WebMI for LAN1 and LAN2
%SR153.1 - EGD for LAN2
%SR153.2 - Modbus TCP Slave for LAN2
%SR153.4 - FTP for LAN2
User should not set other bits of %SR153 and %SR156 to one.
Bootloader
X5CSCAN 15.52May 2021Licensed EnhancementEnhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshootingBootloader, Cscape 9.90 SP4
X5CSCAN 15.52May 2021Licensed EnhancementEnhanced IEC Licensing – Features added.
Bootloader, Cscape 9.90 SP4
X5CSCAN 15.52May 2021Licensed EnhancementMQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177)Bootloader
X5CSCAN 15.52May 2021Licensed EnhancementJ1939 - J1939 protocol may now be licensed and added in the field for all XL4, EXL6, EXLW and X5 products.Bootloader
X5CSCAN 15.52May 2021Bug FixResolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789).Bootloader
X5CSCAN 15.52May 2021Bug FixUnits with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746).Bootloader
X5CSCAN 15.52May 2021Bug FixResolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue.Bootloader
X5CSCAN 15.52May 2021Bug FixFixed an issue where units were not shutting down properly when the battery voltage was below 2.0V.Bootloader
X5CSCAN 15.52May 2021Bug FixResolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713)Bootloader
X5CSCAN 15.52May 2021Bug FixX5 only - Resolved a System Exception fault while accessing WebMI and while microSD was unplugged – immediately after a program download (4551).Bootloader
X5CSCAN 15.52May 2021Bug FixX5 only - Corrected an analog accuracy issue introduced in firmware 15.42 after re-calibration of analog channels. Updating to 15.52 corrects the analog accuracy issue with no re-calibration required (4723).Bootloader
X5CSCAN 15.52May 2021Bug FixCorrected an issue where the Alarm History was not being maintained after a power cycle (4206).Bootloader
X5CSCAN 15.52May 2021Bug FixCorrected an issue where the NTP server was skipping a day after a new year (4910).Bootloader
X5CSCAN 15.52May 2021Bug FixFixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177).Bootloader
X5Download Firmware 15.52 Release Notes
X5CSCAN 15.40July 2020EnhancementDownloadable protocol enable/disable options now available for full Network and also for individual devices Cscape 9.90 SP3
X5CSCAN 15.40July 2020EnhancementDHCP and DNS Support
X5CSCAN 15.40July 2020Enhancement
MQTT - Sparkplug (licensed feature)
X5CSCAN 15.40July 2020EnhancementStructure support in RM blocks
X5CSCAN 15.40July 2020EnhancementAdded X5 Factory Calibration
X5CSCAN 15.40July 2020Bug FixSetpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2Cscape 9.90 SP3
X5CSCAN 15.40July 2020Bug FixCsCAN ladder blocks can now use registers greater than %R2048Cscape 9.90 SP3
X5CSCAN 15.40July 2020Bug FixPID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048Cscape 9.90 SP3
X5CSCAN 15.40July 2020Bug FixIP default HE-WIFIUSB
X5CSCAN 15.40July 2020Bug FixLocal Date (Day) rolls back at month change
X5Download Firmware 15.40 Release Notes
X5CSCAN 15.30October 2019EnhancementBACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process.
X5CSCAN 15.30October 2019EnhancementBasic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410.
X5CSCAN 15.30October 2019Bug FixPossible reset when copying large files from uSD to USB
X5CSCAN 15.30October 2019Bug FixError using wildcards in Removable Media blocks
X5CSCAN 15.30October 2019Bug FixFixed issue where format size of microSD was limited to 1GB
X5CSCAN 15.30October 2019Bug FixAlarms not displayed on web pages in WebMI
X5CSCAN 15.30October 2019Bug FixSystem exception for some programs due to issue with incorrect value for baud rate for J1939
X5CSCAN 15.30October 2019Bug FixFixed an issue that prevented login after download
X5CSCAN 15.30October 2019Bug FixDate format changed to DD-Mon-YY in retentive trend playback
X5CSCAN 15.30October 2019Bug FixAlarm object display did not show live refresh for WebMI
X5CSCAN 15.30October 2019Bug FixOff Delay Timer output was energizing when no power was applied to Timer in first scan
X5CSCAN 15.30October 2019Bug FixHE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration
X5CSCAN 15.30October 2019Bug FixWhen the password data object is set for user access object type, the visibility does not work as expected.
X5Download Firmware 15.30 Release Notes
X5CSCAN 15.20April 2019EnhancementImproved provisions for automatic and manual text wrapping for buttons.Cscape 9.90
X5CSCAN 15.20April 2019EnhancementThe Needle-only gauge (previously Classic-style) now supports Triangle and Rhombus needle styles as in the advanced gauge style.Cscape 9.90
X5CSCAN 15.20April 2019EnhancementAdded support for the Video object for the X5 Controller.Cscape 9.90
X5CSCAN 15.20April 2019EnhancementAdded Digital filtering for the High-speed counting function of several controllers.Cscape 9.90
X5CSCAN 15.20April 2019EnhancementAdded Set CAN ID function block in Advanced Ladder editor.Cscape 9.90
X5CSCAN 15.20April 2019EnhancementImproved Indirect Move function block for more flexible use with Tag-based ladder programming.Cscape 9.90
X5CSCAN 15.20April 2019EnhancementAdded support for multiple baud rates (250K, 500K, 1M) for J1939 Protocol.Cscape 9.90
X5CSCAN 15.20April 2019EnhancementImproved Boot-up TimeCscape 9.90
X5CSCAN 15.20April 2019Bug FixCorrected issue that broke ethernet communications with certain EGD (Ethernet Global Data) configurations.
X5CSCAN 15.20April 2019Bug FixImproved Analog Input jitter on X5 controllers
X5CSCAN 15.20April 2019Bug FixThe Email status was corrected. NOTE: See Cscape 9.90 Help file for updated information.
X5CSCAN 15.20April 2019Bug FixCorrected an issue with email file attachments where the first letter of the attached file name was cut off.
X5CSCAN 15.20April 2019Bug FixImproved EXL10 Backlight dimming. In some cases, dimming to 50% previously caused flickering.
X5CSCAN 15.20April 2019Bug FixMultiple improvements to rechargeable battery handling.*
X5CSCAN 15.20April 2019Bug FixCorrected issues where FTP was not working in certain circumstances.
Download PUN Notes for Power Loss Details
Download Firmware 15.20 Release Notes

You may also like…

Title

Go to Top