All EXL10 control PLC units feature a built-in logic engine, operator interface, networking and I/O.

Pricing is USD

*These PLCs are marked as Mature and are not recommended for new applications – going forward we recommend a seamless upgrade to the XL10 Prime

Current lead time is 2 – 6 weeks.

 

This controller is BABAA Compliant

 

 

SKU: N/A Category:

Description

EXL10

Logic engine features 1MB of application memory with a 0.04 mS/K logic scan. Online Programming Mode (making logic changes on the fly without going thru stop mode) is supported.

Operator Interface features include:

  • 640×480 LCD TFT color graphics display with a high resolution resistive touchscreen
  • 7 function keys and a system key
  • USB 2.0 On-the-Go port (mini-B 5pin) is available for programming
  • USB 2.0 Host port (A) is available for exchanging files with USB FLASH drives
  • Two (2) RS-232/485 ports support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols

Networking features include:

  • (2) built-in 10/100 Ethernet port
  • (2) integrated CAN ports that support CsCAN and either CANopen, J1939, or DeviceNet Scanner simultaneously

All units feature a microSD slot, supporting at least 32GB.

Model Lineup

CONTROLLER MODELCONFIGURATION
HE-EXV1E0No built-in I/O
HE-EXV1E212 DC in, 6 Relay Out, 4 – 12-bit Analog In
HE-EXV1E312 DC in, 12 DC Out, 2 – 12-bit Analog In
HE-EXV1E424 DC in, 16 DC Out, 2 – 12-bit Analog In
HE-EXV1E512 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out
HE-EXV1E612 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out
*Up To six mA/V In, mA/V RTD/Tc, and mA/V Out
SPECIAL ORDER (*)
Part Number ExtensionDescription
-10 With Thermistor on input 1 and 2. Models 2, 3, and 4 only.
-14With analog inputs converted to thermistor support only, removing (mA/V) support. Model 2 only.
-441WebMI License Unlimited pre-loaded OBS as of 4-1-26. Available on XL10 Prime
-442Enhanced IEC License pre-loaded
-445MQTT License pre-loaded
-602With screw type I/O terminals. Model 6 only.
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks.
For combinations of adder options, please contact the factory – 877.665.5666

Specifications

CONTROLLER
Ladder Logic Memory1 MB
Logic Scan Rate0.04 mS/K
Removable MemorymicroSD
Local Comment StorageYes
Floating Point SupportYes
AutoTune PID CapableYes
OPERATOR INTERFACE
Characters / Pixels640x480 (450 nit typical)
Display Technology10.4” VGA TFT Color
Character Heightselectable fonts
Number of Pages1023
Fields or Objects per Page1023
Total Keys8
Function Keys7
OEM Faceplate AvailableYes
I/O
Built-in I/O Points22-44
SmartStix, SmartRail, SmartBlock I/O Supportyes, CsCAN and Ethernet
Digital Inputs / Outputs, max2048 / 2048
Analog Inputs / Outputs, max512 / 512
General Purpose Registers (words)50000
General Purpose Internal Coils (bits)32768 (16384 retentive)
ETHERNET/INTERNET
Ethernet SupportStandard, 2 Ports
Remote AccessWebMI, HTTP or EnvisionRV
Remote File AccessFTP or EnvisionFX
IIoT Support MQTT (Sparkplug)
SERIAL COMMUNICATIONS
Total Active Ports3
RS-232 Ports / RS-485 PortsRS-232 & RS-485; RS-232 / RS-485
PLC / Drive ProtocolsYes
RTU / Modbus Master / SlaveYes
Serial ASCII In / OutYes
USB Ports (A and Mini-B)Yes
NETWORKING
Integrated CAN Networks2
Supported CAN NetworksCsCAN, CANopen, J1939 and DeviceNet Master (layer 3 as a selectable option)
Maximum CAN Distance500m per segment, 4 segments maximum
Programming over CAN       CsCAN only
Supported CAN ProtocolsCsCAN plus one of the following: CANopen, DeviceNet Master (layer-3 as a selectable option - one only), SAE J1939
PHYSICAL SPECIFICATIONS
Height9.08" / 230.60 mm
Width11.94" / 303.30 mm
Depth2.43" / 61.70 mm
I/O Module DepthCOM option adds 1.08" / 27.40 mm
OPERATING SPECS & STANDARDS
Operating Temperature-10 to 60°C
Storage Temperature-20°C to +60°C
Humidity (non-condensing)5 to 95%
Product Certifications/ApprovalsUL Class I Div II, CE
Environmental RatingUL Type 1, 3R, 4, 4x, 12, 12k, 13

Documentation & Resources

DocumentReference NumberLink to Download
SALES LITERATURE
XL Series Comparison GuideHA-102
DRAWINGS2D ELECTRICAL2D MECHANICAL3D MECHANICAL
HE-EXV1E0 Model 0
HE-EXV1E2 Model 2
HE-EXV1E3 Model 3
HE-EXV1E4 Model 4
HE-EXV1E5 Model 5
HE-EXV1E6 Model 6
TECHNICAL DOCUMENTATION
EXL10 User ManualMAN1029Download
EXL10 Quick Reference GuideMAN1197Download
HE-EXV1E0 DatasheetMAN1185Download
HE-EXV1E2 DatasheetMAN1186Download
HE-EXV1E3 DatasheetMAN1187Download
HE-EXV1E4 DatasheetMAN1188Download
HE-EXV1E5 DatasheetMAN1189Download
HE-EXV1E6 DatasheetMAN1190Download
SUPPLEMENTAL
App Guide for Updating FirmwareMAN1011Download
Firmware Restore GuideMAN1141
App Guide for Adding Custom Splash ScreenMAN0990
Thermistor SupplementSUP0797
Ethernet Supplement ManualSUP0740Download
Cutout Template SheetSUP1551

Certifications

Certification TypeDownload Certificate
BABAA - Build America, Buy America Act
UL
CE Declaration of Conformity
ISO 9001: 2015
Lithium Battery Test Summary

Firmware Review Notes

PRODUCTVERSIONRELEASE DATETYPEDETAILSREQUIREMENTS
XL4, EXL6, EXLW, XL7, EXL1015.762/4/26EnhancementSecurity improvements
Ethernet ports are open only if they are configured in Cscape and downloaded to the device.
Bootloader, Cscape 10.1 or later
XL4, EXL6, EXLW, XL7, EXL1015.762/4/26Bug FixResolved
Email sending using the cell modem was not working after restoring the signal, resulting in a send failure.
Bootloader
XL4, EXL6, EXLW, XL7, EXL1015.762/4/26Bug FixResolved
In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers.
Bootloader
XL4, EXL6, EXLW, XL7, EXL1015.762/4/26Bug FixResolved
The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports.
Bootloader
Download >Download Firmware 15.76 Release Notes
XL4, EXL6, EXLW, XL7, EXL1015.747/25/25Bug Fix• Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data.
• Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample
Bootloader, Cscape 10.1 or later
XL4, EXL6, EXLW, XL7, EXL1015.747/25/25Bug FixResolved: Bitmaps were not being displayed on the device.Bootloader
XL4, EXL6, EXLW, XL7, EXL1015.747/25/25Bug FixResolved: The device was not sending the NMT Start Command to CANOpen devices after power up.Bootloader
XL4, EXL6, EXLW, XL7, EXL1015.747/25/25Bug FixResolved: The email stopped working when using Secomea Email Relay on port 25 without authentication.Bootloader
Download >Download Firmware 15.74 Release Notes
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24EnhancementAdded support for OCSIO models ADC270 and DQM602.Bootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24EnhancementRetain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards.Bootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: Modbus Client sending Zero Value when Holding Register is Not ZeroBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: CAN2 stopped working after several power cyclesBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media blockBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: UTC time was not updating when downloaded from CscapeBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: Title bar of password object was showing nonsense language when Unicode fonts were createdBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: WebMI alarm history page not listing the RTN alarmsBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controllerBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: CV value of a PID block was not being updated when configured in the Enhanced IEC programBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocksBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elementsBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: Gmail was not working for certain SMTP IPsBootloader, Cscape 9.90 SP10
XL4, EXL6, EXLW, XL7, EXL1015.709/20/24Bug FixResolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view statusBootloader, Cscape 9.90 SP10
Download >Download Firmware 15.70 Release Notes

Videos

You may also like…

Go to Top