Call Us: 877-665-5666

X10

On backorder - current lead times are up to 6 weeks.

The X10 is the fifth product of the streamlined Micro OCS Series of embedded I/O controllers. All units feature a built-in logic engine, operator interface, networking and I/O. Use the dropdown below to select from our two distinct models:  X10R (relay outputs) and X10A (digital outputs)

Current lead time is up to 6 weeks.                       

To try out an X10 Starter Kit CLICK HERE

HORNER APP

The Horner App is the first automation app to give customers the ability to access all WebOCS enabled controllers with their iOS or Android phone or tablet.

 

 

Please login to see price/buy item.
SKU: N/A Category:

Description

COMPREHENSIVE ADVANTAGE
With the addition of the X10 OCS controller, our engineers at Horner Automation have designed a slim, versatile, and complimentary product to our existing line of robust industrial solutions. The X10, when utilized as an introductory piece, empowers your organization to grow by seamlessly incorporating additional Horner solutions (such as our more basic X4, and X7 OCS controllers) to your expanding system.

POWERFUL CONTROL SOLUTION
In the market of cost-effective all-in-one controllers, the web-compatible X10 is unmatched in its abilities to control, communicate, and log data. Suited for applications across a diverse range of industries, the X10 exceeds standards (and expectations). With its capable processor speed and larger, intuitive user interface, the suite of capabilities within the X10 expand upon our established X4 and X7 products.

FLEXIBLE I/O CONFIGURATION
In an effort to make the latest Horner OCS controllers as widely applicable as possible, the X10 has been designed with a streamlined set of onboard I/O supporting an impressive array of applications. Discrete manufacturing is well supported with 20-24 digital I/O points – including high-speed inputs and outputs. Are your requirements process oriented? The X10 includes analog inputs and outputs, with support for 4-20mA signals and RTD temperature sensors. If the built-in I/O isn’t enough for your specific application – easily expand via Ethernet, CAN, or RS-485.

SPACE-SAVING DESIGN
The wide, sleek profile of the X10 enables you to fit more in your panel, saving space and resources. The X10 packs a big picture into an overall small package. With a 6.607” x 10.433” cutout, this 10” wide aspect screen is very friendly, intuitive, and clear.

Model Lineup

Built-In Inputs/OutputsHE-X10A (Model A)HE-X10R (Model R)
DC In1212
DC Out122
Relaysn/a6
HS In44
HS Out22
mA In4 4
mA Out22
Note: There are four high-speed inputs of the total DC Inputs. There are two high-speed outputs of the total DC outputs.
Note: Model A supports sourcing outputs. Model R DC outputs are sinking with integral pull up resistors.
SPECIAL ORDER (*)
Part Number ExtensionDescription
-441WebMI License Unlimited pre-loaded
-443CANopen License is pre-loaded, CsCAN support is removed
-444BACnet IP/MSTP License is pre-loaded
(*) Not available for purchase on the web store. Please call factory for product availability. Lead time on special order products is 4-6 weeks.
For combinations of adder options, please contact the factory – 877.665.5666

Specifications

CONTROLLER
Ladder Logic Memory256 kB
Logic Scan Rate0.4 mS/K
Removable MemorymicroSD
Local Comment StorageYes
Floating Point SupportYes
AutoTune PID CapableYes
OPERATOR INTERFACE INTERFACE
Characters / Pixels1024 x 600
Display TechnologyLCD with LED 300 nits
Character HeightSelectable Fonts
Number of Pages250
Fields or Objects per Page100
Total Keys5 (on screen)
Function Keys4 (on screen)
OEM Faceplate AvailableNo
I/O
Built-in I/O Points26 (model R); 30 (model A)
SmartStix, SmartRail, SmartBlock I/O Supportyes, CsCAN
Digital Inputs / Outputs, max1024 / 1024
Analog Inputs / Outputs, max256 / 256
General Purpose Registers (words)5000 retentive
General Purpose Internal Coils (bits)2,048 (1,024 retentive)
SERIAL COMMUNICATIONS
Total Active Ports2
RS-232 Ports / RS-485 PortsRS-232 / RS-485 (1 of each)
PLC / Drive ProtocolsLimited
RTU / Modbus Master / SlaveYes
Serial ASCII In / OutYes
USB Ports (A and Mini-B)Mini-B only
NETWORKING
Integrated CAN NetworksStandard
Supported CAN NetworksCsCAN
Maximum CAN Distance1,640 ft.
Programming over CAN Yes
PHYSICAL SPECIFICATIONS
Height6.5″ / 166.20 mm
Width10.4″ / 263.9 mm
Depth2.2″ / 55.8 mm
OPERATING SPECIFICATIONS & STANDARDS
Operating Temperature-10 to 60°C
Humidity (non-condensing)5 to 95%
Voltage10-30 VDC
Product CertificationsCE, C’
Environmental RatingUL 50E Type 1, 4x, 12, 12k, 13 (indoor use)

Documentation & Resources

DocumentReference NumberLink to Download
SALES LITERATURE
X10 Sales SheetHA-340
OCS Comparison GuideHA-294
Starter Kit Sales SheetHA-345
TECHNICAL DOCUMENTATION
X10 User ManualMAN1277Download
X10 DatasheetMAN1278Download
X10 Quick Reference GuideMAN1279Download
DRAWINGS2D ELECTRICAL2D MECHANICAL3D MECHANICAL
HE-X10A / HE-X10R
SUPPLEMENTAL
App Guide for Updating FirmwareMAN1011
Ethernet Supplement ManualSUP0740Download

Certifications

Certification TypeDownload Certificate
UL
CE Declaration of Conformity
ISO 9001: 2015
Lithium Battery Test Summary

Videos

For more X10 and other videos, please visit our YouTube Channel

Firmware Review Notes

PRODUCTVERSIONRELEASE DATETYPEDETAILSREQUIREMENTS
X10FW 15.82April 2024EnhancementResolved issue where System menu | View Status displays both Build version and Firmware version.
X10FW 15.82April 2024Bug FixResolved issue where unit locked up / froze when serial downloadable protocol was configured. This occurred randomly and was seen in limited hardware
X10FW 15.82April 2024Bug FixResolved issue where hardfault errors occur when CANopen SmartRail is configured in the program and downloaded
X10FW 15.82April 2024Bug FixResolved issue where endless loop of nameless folders were being created when "A:\" in Copy RM block was entered by the user.
X10FW 15.82April 2024Bug FixResolved issue where title bar of password object was showing mixed characters when unicode fonts were created.
X10FW 15.82April 2024Bug FixResolved issue where WebMI alarm history page not listing the RTN alarms
X10FW 15.82April 2024Bug FixResolved issue where touching one place on the screen registers touch on other parts of the screen. Only seen in some but not all, X10 hardware(s).
X10CSCAN 15.76July 2023EnhancementOCSIO support has been added along with new modules - DIM610 and DQM606. NOTE: New modules require Cscape 9.90 SP9 onwards and OCSIO firmware
X10CSCAN 15.76July 2023EnhancementIncreased PID blocks support from 4 to 8 for Micro OCS series. NOTE: Requires Cscape 9.90 SP9 onwards.
X10CSCAN 15.76July 2023Bug FixResolved erasing of analog calibration information after updating to FW 15.70 (10418) NOTE: Addressed issue related to both upgrade and downgrade of firmware.
X10CSCAN 15.76July 2023Bug FixResolved touch calibration issue after loading FW 15.70 (10553) NOTE: The cross hair at the upper left of the screen does not work in Touch Calibration
X10CSCAN 15.76July 2023Bug FixResolved issue when timer output was turning on at startup. (7639 / 1390)
X10CSCAN 15.76July 2023Bug FixResolved issue when after power cycle, the first pulse output duration was either missed or too short. (7634)
X10CSCAN 15.76July 2023Bug FixResolved issue when Filename Counter was not working properly if a file with screen capture was downloaded previously. (5717)
X10CSCAN 15.76July 2023Bug FixResolved issue when unit would lose communication with Cscape over Ethernet when there were multiple slaves configured in the program but not connected. (4700) NOTE: Occurrence of issue has been reduced
X10CSCAN 15.76July 2023Bug FixResolved issue when WebMI license was lost if there was a flat or faulty controller battery. License duration check will not be done for lifetime licenses, so even if battery fails, license will be valid for lifetime licenses. (3429) NOTE: For permanent license, check for RTC time has been removed
X10CSCAN 15.76July 2023Bug FixResolved issue when screen response to Momentary Button was not working properly for a large button configured on the screen. (8439)
X10CSCAN 15.76July 2023Bug FixResolved issue when screen saver was not working for a few hardware revisions. (8018)
X10CSCAN 15.76July 2023Bug FixResolved issue when frequent timeouts and reconnects were seen on units running EtherNet/IP server. (8541)
X10CSCAN 15.76July 2023Bug FixResolved issue with Modbus TCP communication when 6 or more devices were used. (8362)
X10CSCAN 15.76July 2023Bug FixResolved issue when combining characters like Thai fonts were not displayed properly in the Graphics Editor. (3878) NOTE: Requires Cscape 9.90 SP9 onwards.
X10CSCAN 15.76July 2023Bug FixResolved ethernet port lock up issues. (8464 / 7052 / 7508)
X10CSCAN 15.76July 2023Bug FixResolved flash erase issue on a few hardware revisions after loading 15.60 firmware. (9197)
X10CSCAN 15.76July 2023Bug FixResolved issue when user access alarms webpage via web designer model device displayed HardFault error. (8288) NOTE: Issue was seen when unicode strings were configured in alarms configuration.
X10CSCAN 15.76July 2023Bug FixResolved issue when device displayed HardFault error when Modbus TCP/IP device list configured with more than 32 slaves was downloaded to device. (7495 / 8531)
X10CSCAN 15.76July 2023Bug FixResolved issue when emails sent from the OCS were being treated as spam emails due to email header missing time zone. (9105)
X10CSCAN 15.76July 2023Bug FixResolved issue when Quadrature HSC output was not working. (6468)
X10CSCAN 15.76July 2023Bug FixResolved issue when accessing webpages used to display frequent "connection timeout". (9869 / 7583)
X10CSCAN 15.76Download Firmware 15.76 Release Notes
X10CSCAN 15.60December 2022Bug FixResolved input glitch caused by beeper function.Bootloader
X10Download Firmware 15.58 Release Notes
X10CSCAN 15.58December 2021EnhancementAdded support for alternative hardware components.Bootloader
X10Download Firmware 15.58 Release Notes
X10CSCAN 15.54August 2021EnhancementWebMI status bits have been added for Session Count: %SR101.5 to SR101.7Bootloader
X10CSCAN 15.54August 2021Bug FixResolved Issue: When using the Report Editor, an extra space or multiple spaces was being added to the end of the report before the Carriage Return.. (4699)Bootloader
X10CSCAN 15.54August 2021Bug FixResolved Issue: Real to DINT conversion was giving incorrect result for some values. (5314)Bootloader
X10CSCAN 15.54August 2021Bug FixMade touch calibration faster. (1420)Bootloader
X10CSCAN 15.54August 2021Bug FixResolved Issue: ModbusTCP communication was not starting until Reacquire Time has timed out during power up or sometimes when unit is put from Idle to Run mode. (5042)Bootloader
X10CSCAN 15.54August 2021Bug FixResolved Issue: sometimes microSD card was not detecting / reading properly when plugged and unplugged continuously. (4703)Bootloader
X10CSCAN 15.54August 2021Bug FixResolved WebMI Issue: Previous session(s) was not getting closed which resulted in connection timeout during long run as max sessions were reached. (4980)Bootloader
X10CSCAN 15.54August 2021Bug FixResolved Issue: MJ1 RS 232 hardware Handshake fails (DSR / DTR) - issue related to Modem. (5171)Bootloader
X10CSCAN 15.54August 2021Bug FixResolved Issues: (5398) Modbus TCP. When Update Interval was utilized (set other than zero), if packets were delayed beyond the set Update Interval time, previous sockets were getting closed before the re-connect packet was sent. And therefore comms would not recover automatically. The issue would typically be seen when the Update Interval was set to time periods that exceed the server timeout time.Bootloader
X10Download Firmware 15.54 Release Notes
X10CSCAN 15.52May 2021EnhancementIncreased ladder size from 256KB to 512KB. (4318)Bootloader
X10CSCAN 15.52May 2021EnhancementX10 only - Increased bmp size from 4MB to 6MBBootloader
X10CSCAN 15.52May 2021EnhancementX10 only - Reduced Auto calibration timeBootloader
X10CSCAN 15.52May 2021Bug FixX7 & X10 only - Resolved issue where slider buttons were too small. (4318)Bootloader
X10CSCAN 15.52May 2021Bug FixResolved issue where Email with TLS encryption (Gmail) was not working with the ethernet downloadable protocol. (3711)Bootloader
X10CSCAN 15.52May 2021Bug FixResolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943)Bootloader
X10CSCAN 15.52May 2021Bug FixResolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646)Bootloader
X10Download Firmware 15.52 Release Notes

You may also like…