These manuals describe how to update or change firmware on the Horner OCS Controllers. Updating firmware to the newest version adds new benefits to the controller. Also, changing firmware is necessary when changing communications between CsCAN and CANopen, so the controller firmware changelog can help your products stay up to date.
Remember: Updating firmware will clear the application program, screens, configurations, and register data.
If required, make sure to backup program and register data before updating firmware. The controller’s User Manual has instructions for doing backups.
You can view and download all Release Notes below:
MODULAR CONTROLLERS
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| CPU200/250 | 16.20 | April 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP2 onwards | ||
| CPU200/250 | 16.20 | April 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP2 onwards | ||
| CPU200/250 | 16.20 | April 2026 | Enhancement | Added support for 76800K baud rate in BACNet MSTP protocol Note – Requires BACNetIP Server dll v5.11 onwards | ||
| CPU200/250 | 16.20 | April 2026 | Enhancement | Added support to apply license through SR register and System Menu | ||
| CPU200/250 | 16.20 | April 2026 | Bug Fix | Resolved issue where the device displayed an exception when an IEC program was configured with Modbus Master block and the array of structures was enabled | ||
| CPU200/250 | 16.20 | April 2026 | Bug Fix | Resolved issue where the device would randomly restart when an IP address was configured with registers and values was set to zero | ||
| CPU200/250 | 16.20 | April 2026 | Bug Fix | Resolved issue where the slider was drifting its position when the user held the slider in one position Note – Applicable to only X4 and X10 models | ||
| CPU200/250 | 16.20 | April 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP2 onwards | ||
| CPU200/250 | 16.20 | April 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| CPU200/250 | Download Firmware 16.20 Release Notes | |||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| CPU300 | 17.30 | October 2025 | Enhancement | Added CPU300 model support. | cpu300, support | |
| CPU300 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards | ocsio, base, identification | |
| CPU300 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | ocs360, system, menu | |
| CPU300 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | boot-up, message | |
| CPU300 | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | security, ethernet, ports | |
| CPU300 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | return, state, alarms | |
| CPU300 | 17.30 | October 2025 | Enhancement | Added the following system register bits for Save PGM Fail and Load PGM fail. SR164.11 – Save PGM fail bit SR164.12 – Load PGM fail bit | system, register, bit, save, pgm | |
| CPU300 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | system, register, bit, restore | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | loading, pgm, error | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | video, object, resolution | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - The screen was loading objects with default settings first, and then followed by the Enhanced Display Attributes structures configured | enhanced, display, attributes | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Button touch was not working if the button visibility was configured as OFF and showed the icon option was unchecked. | button, touch | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | lan2, lan1, data, registers | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | email, sending, cell, modem | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | ethernet, configuration, ip, address | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | ethernet, ip, protocol | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - The way the multi-position selector switch works. • For Example – A three-position selector switch works from 0-1-2, 0-1-2 positions to 0-1-2, 2-1-0 positions when operated. • Note - Requires Cscape 10.2 onwards | multi-position, selector, switch | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - The following gesture changes are in the menu object page: • The left side of the menu object page is mainly used for scrolling purpose - touch will not select any menu item. • The right side of the menu object page is for scrolling and selecting / editing purposes. | menu, object | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved – The mouse scroll was not working when using an external wired mouse for operations. | mouse, scroll, external | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | wi-fi, system, menu | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block is in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (Applies to 3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | canopen, protocol | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Alarm acknowledgment was not working in WebMI Plus pages. | alarm, acknowledgment, webmi | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Improved the response time of toggle buttons when a greater number of buttons were configured in a screen. | toggle, buttons | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Modbus TCP/IP configured with external registers was not working for a program created in Cscape 9.90 and downloaded from Cscape 10. | modbus, tcp/ip, external, registers | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Alarms were not being displayed on the summary and history list after 170 alarms were shown in the history list in WebMI Plus pages. | alarms, display, webmi | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved – Occasionally, System Menu pages were displayed when the System Key is pressed, even though the System Lock was enabled. | system, menu, lock | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | multiple, modbus, blocks | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3 and 4 | analog, input, values | |
| CPU300 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmwear version 48 onwards. | auto-populate, ocsio | |
MICRO OCS SERIES
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| X2 | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
| X2 | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
| X2 | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
| X2 | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein alarm history list was not getting retained after power cycle (5817) NOTE: Applicable to X2 only. | Bootloader | |
| X2 | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
| X2 | Download Firmware 15.62 Release Notes | |||||
| X2 | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
| X2 | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| X4 | 16.20 | April 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP2 onwards | ||
| X4 | 16.20 | April 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP2 onwards | ||
| X4 | 16.20 | April 2026 | Enhancement | Added support for 76800K baud rate in BACNet MSTP protocol Note – Requires BACNetIP Server dll v5.11 onwards | ||
| X4 | 16.20 | April 2026 | Enhancement | Added support to apply license through SR register and System Menu | ||
| X4 | 16.20 | April 2026 | Bug Fix | Resolved issue where the device displayed an exception when an IEC program was configured with Modbus Master block and the array of structures was enabled | ||
| X4 | 16.20 | April 2026 | Bug Fix | Resolved issue where the device would randomly restart when an IP address was configured with registers and values was set to zero | ||
| X4 | 16.20 | April 2026 | Bug Fix | Resolved issue where the slider was drifting its position when the user held the slider in one position Note – Applicable to only X4 and X10 models | ||
| X4 | 16.20 | April 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP2 onwards | ||
| X4 | 16.20 | April 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| X4 | Download Firmware 16.20 Release Notes | |||||
| X4 | 16.10 | October 2025 | Enhancement | Added support for CPU200 (CPU series) Note: Requires Cscape 10.1 SP1 onwards | ||
| X4 | 16.10 | October 2025 | Enhancement | Added J1939 support Note(s): • This is enabled through the following extension – J2M58-12I15-92C52-38R6D-95OX5 • Requires J1939 license • Requires Cscape 10.2 onwards | ||
| X4 | 16.10 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note: Requires Cscape 10.2 onwards | ||
| X4 | 16.10 | October 2025 | Enhancement | Security improvements: Ethernet ports are opened only if they are configured in Cscape and downloaded to the device. | ||
| X4 | 16.10 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| X4 | 16.10 | October 2025 | Enhancement | Added System Register Bit for the restore operation from logic. Restore operation: %SR164.16 | ||
| X4 | 16.10 | October 2025 | Enhancement | Added System Register Bit for indicating the status of the CAN port Indicates a CAN port error: %SR4.14 | ||
| X4 | 16.10 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS, and it was not displaying any error message on the device. | ||
| X4 | 16.10 | October 2025 | Bug Fix | Resolved - Overlapping of graphic objects wherein the objects were disappearing or were becoming distorted. | ||
| X4 | 16.10 | October 2025 | Bug Fix | Resolved - Ethernet/IP protocol stopped working if the Consumed / Produced configuration exceeded 128 words. | ||
| X4 | 16.10 | October 2025 | Bug Fix | Resolved - Email stopped working when Port 25 was used without authentication, but the response from the email server was switching to TLS. Due to this resolution, if the username and password are not configured with Port 25, the firmware uses the SMTP protocol without authentication, ignoring switching to TLS. | ||
| X4 | 16.10 | October 2025 | Bug Fix | Enhanced filename (RM blocks, PGM) support from 8 characters to 47 characters support | ||
| X4 | 16.10 | October 2025 | Bug Fix | Resolved: Loading a specific PGM file displayed a “BAD Format” error on the device. | ||
| X4 | 16.10 | October 2025 | Bug Fix | Resolved the following issues related to WebMI: • FTP issue: An FTP error was being displayed while publishing webpages after a power cycle. • WebMI pages not loading: Web pages were not being loaded after signing in. | ||
| X4 | 16.10 | October 2025 | Bug Fix | Resolved: OCS-I/O configured with dynamic configuration was not working. | ||
| X4 | 16.10 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 FW Version 48 onwards. | ||
| X4 | Download Firmware 16.10 Release Notes | |||||
| X4 | 15.94 | July 2025 | Bug Fix | Resolved: Touching one part of the screen is affecting other parts of the screen. | ||
| X4 | 15.94 | Download Firmware 15.92 Release Notes | ||||
| X4 | 15.92 | May 2025 | Enhancement | “Set Local ID” option is supported for both CsCAN and CANOpen network types (Mantis #7873). Note – Requires Cscape version 10.1 onwards | ||
| X4 | 15.92 | May 2025 | Bug Fix | Resolved: Graphics objects on screen were overlapping the System Menu function keys. | ||
| X4 | 15.92 | May 2025 | Bug Fix | Security improvements were made related to the Ethernet ports. | ||
| X4 | 15.92 | May 2025 | Bug Fix | Resolved: For [some] hardware revisions, touch was not working on the left corner from top to bottom. Note: Applicable to X10 models only. | ||
| X4 | 15.92 | May 2025 | Bug Fix | Resolved: The modified baud rate was not updated in the CANOpen slave device when both master and slave devices were in an operational state. | ||
| X4 | 15.92 | May 2025 | Bug Fix | Resolved: “Delete All” functionality was not working in the Removable Media Object when the user configures the directory as “A:/” | ||
| X4 | 15.92 | May 2025 | Bug Fix | Resolved: Sometimes junk CSV files were created on the MicroSD card when Datalog and serial ports were configured. | ||
| X4 | 15.92 | May 2025 | Bug Fix | Resolved: Auto-populate issue with OCSIO. | ||
| X4 | 15.92 | Download Firmware 15.92 Release Notes | ||||
| X4 | FW 15.90 | February 2025 | Enhancement | Added support for OCSIO DQM602. | ||
| X4 | FW 15.90 | February 2025 | Enhancement | Added retain variables support for Variable-Based Advanced Ladder (VBAL). Note: Requires Cscape version 10.1 onwards. | ||
| X4 | FW 15.90 | February 2025 | Enhancement | Added System Register bit for system menu access. Note: Requires Cscape version 10.1 onwards. | ||
| X4 | FW 15.90 | February 2025 | Enhancement | Added “Alpha Filter Constant” function for analog inputs. Notes: • Requires Cscape version 10.1 onwards • Ranges from 1 – 10 (1 refers to 0.01 filtering and 10 refers to 0.1 filtering) • The lower the value, the heavier the filtering | ||
| X4 | FW 15.90 | February 2025 | Bug Fix | Resolved: The momentary button was behaving as if it was a toggle button when it was placed at the top right corner of the screen. | ||
| X4 | FW 15.90 | February 2025 | Bug Fix | Resolved: Read RM block was reading entire elements/data for an ASCII data type instead of reading only the configured number of elements. | ||
| X4 | FW 15.90 | February 2025 | Bug Fix | Resolved: Time/date object was not displaying data correctly on web pages when the user refreshed the web pages. | ||
| X4 | FW 15.90 | February 2025 | Bug Fix | Resolved: User was seeing a delay of up to 10 seconds when trying to trigger a data write operation in ASCII TCP/IP Client protocol (when the slave device was re-establishing the connection) Notes: • Provided a setting in the protocol network configuration to control the serversion reconnection interval (Fast-2 Seconds, Medium-5 Seconds, Slow-10 Seconds). • This requires ASCII TCP/IP Protocol dll v5.04 onwards. | ||
| X4 | FW 15.90 | Download Firmware 15.90 Release Notes | ||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| X5 | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| X5 | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| X5 | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| X5 | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| X5 | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| X5 | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| X5 | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| X5 | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| X5 | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| X5 | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| X7 | 16.20 | April 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP2 onwards | ||
| X7 | 16.20 | April 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP2 onwards | ||
| X7 | 16.20 | April 2026 | Enhancement | Added support for 76800K baud rate in BACNet MSTP protocol Note – Requires BACNetIP Server dll v5.11 onwards | ||
| X7 | 16.20 | April 2026 | Enhancement | Added support to apply license through SR register and System Menu | ||
| X7 | 16.20 | April 2026 | Bug Fix | Resolved issue where the device displayed an exception when an IEC program was configured with Modbus Master block and the array of structures was enabled | ||
| X7 | 16.20 | April 2026 | Bug Fix | Resolved issue where the device would randomly restart when an IP address was configured with registers and values was set to zero | ||
| X7 | 16.20 | April 2026 | Bug Fix | Resolved issue where the slider was drifting its position when the user held the slider in one position Note – Applicable to only X4 and X10 models | ||
| X7 | 16.20 | April 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP2 onwards | ||
| X7 | 16.20 | April 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| X7 | Download Firmware 16.20 Release Notes | |||||
| X7 | 16.10 | October 2025 | Enhancement | Added support for CPU200 (CPU series) Note: Requires Cscape 10.1 SP1 onwards | ||
| X7 | 16.10 | October 2025 | Enhancement | Added J1939 support Note(s): • This is enabled through the following extension – J2M58-12I15-92C52-38R6D-95OX5 • Requires J1939 license • Requires Cscape 10.2 onwards | ||
| X7 | 16.10 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note: Requires Cscape 10.2 onwards | ||
| X7 | 16.10 | October 2025 | Enhancement | Security improvements: Ethernet ports are opened only if they are configured in Cscape and downloaded to the device. | ||
| X7 | 16.10 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| X7 | 16.10 | October 2025 | Enhancement | Added System Register Bit for the restore operation from logic. Restore operation: %SR164.16 | ||
| X7 | 16.10 | October 2025 | Enhancement | Added System Register Bit for indicating the status of the CAN port Indicates a CAN port error: %SR4.14 | ||
| X7 | 16.10 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS, and it was not displaying any error message on the device. | ||
| X7 | 16.10 | October 2025 | Bug Fix | Resolved - Overlapping of graphic objects wherein the objects were disappearing or were becoming distorted. | ||
| X7 | 16.10 | October 2025 | Bug Fix | Resolved - Ethernet/IP protocol stopped working if the Consumed / Produced configuration exceeded 128 words. | ||
| X7 | 16.10 | October 2025 | Bug Fix | Resolved - Email stopped working when Port 25 was used without authentication, but the response from the email server was switching to TLS. Due to this resolution, if the username and password are not configured with Port 25, the firmware uses the SMTP protocol without authentication, ignoring switching to TLS. | ||
| X7 | 16.10 | October 2025 | Bug Fix | Enhanced filename (RM blocks, PGM) support from 8 characters to 47 characters support | ||
| X7 | 16.10 | October 2025 | Bug Fix | Resolved: Loading a specific PGM file displayed a “BAD Format” error on the device. | ||
| X7 | 16.10 | October 2025 | Bug Fix | Resolved the following issues related to WebMI: • FTP issue: An FTP error was being displayed while publishing webpages after a power cycle. • WebMI pages not loading: Web pages were not being loaded after signing in. | ||
| X7 | 16.10 | October 2025 | Bug Fix | Resolved: OCS-I/O configured with dynamic configuration was not working. | ||
| X7 | 16.10 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 FW Version 48 onwards. | ||
| X7 | 16.10 | October 2025 | Bug Fix | Resolved: The slider was drifting from its position when the user held the slider in one position | ||
| X7 | Download Firmware 16.10 Release Notes | |||||
| X7 | 15.94 | July 2025 | Bug Fix | Resolved: Touching one part of the screen is affecting other parts of the screen. | ||
| X7 | 15.94 | Download Firmware 15.92 Release Notes | ||||
| X7 | 15.92 | May 2025 | Enhancement | “Set Local ID” option is supported for both CsCAN and CANOpen network types (Mantis #7873). Note – Requires Cscape version 10.1 onwards | ||
| X7 | 15.92 | May 2025 | Bug Fix | Resolved: Graphics objects on screen were overlapping the System Menu function keys. | ||
| X7 | 15.92 | May 2025 | Bug Fix | Security improvements were made related to the Ethernet ports. | ||
| X7 | 15.92 | May 2025 | Bug Fix | Resolved: For [some] hardware revisions, touch was not working on the left corner from top to bottom. Note: Applicable to X10 models only. | ||
| X7 | 15.92 | May 2025 | Bug Fix | Resolved: The modified baud rate was not updated in the CANOpen slave device when both master and slave devices were in an operational state. | ||
| X7 | 15.92 | May 2025 | Bug Fix | Resolved: “Delete All” functionality was not working in the Removable Media Object when the user configures the directory as “A:/” | ||
| X7 | 15.92 | May 2025 | Bug Fix | Resolved: Sometimes junk CSV files were created on the MicroSD card when Datalog and serial ports were configured. | ||
| X7 | 15.92 | May 2025 | Bug Fix | Resolved: Auto-populate issue with OCSIO. | ||
| X7 | 15.92 | Download Firmware 15.92 Release Notes | ||||
| X7 | FW 15.90 | February 2025 | Enhancement | Added support for OCSIO DQM602. | ||
| X7 | FW 15.90 | February 2025 | Enhancement | Added retain variables support for Variable-Based Advanced Ladder (VBAL). Note: Requires Cscape version 10.1 onwards. | ||
| X7 | FW 15.90 | February 2025 | Enhancement | Added System Register bit for system menu access. Note: Requires Cscape version 10.1 onwards. | ||
| X7 | FW 15.90 | February 2025 | Enhancement | Added “Alpha Filter Constant” function for analog inputs. Notes: • Requires Cscape version 10.1 onwards • Ranges from 1 – 10 (1 refers to 0.01 filtering and 10 refers to 0.1 filtering) • The lower the value, the heavier the filtering | ||
| X7 | FW 15.90 | February 2025 | Bug Fix | Resolved: The momentary button was behaving as if it was a toggle button when it was placed at the top right corner of the screen. | ||
| X7 | FW 15.90 | February 2025 | Bug Fix | Resolved: Read RM block was reading entire elements/data for an ASCII data type instead of reading only the configured number of elements. | ||
| X7 | FW 15.90 | February 2025 | Bug Fix | Resolved: Time/date object was not displaying data correctly on web pages when the user refreshed the web pages. | ||
| X7 | FW 15.90 | February 2025 | Bug Fix | Resolved: User was seeing a delay of up to 10 seconds when trying to trigger a data write operation in ASCII TCP/IP Client protocol (when the slave device was re-establishing the connection) Notes: • Provided a setting in the protocol network configuration to control the serversion reconnection interval (Fast-2 Seconds, Medium-5 Seconds, Slow-10 Seconds). • This requires ASCII TCP/IP Protocol dll v5.04 onwards. | ||
| X7 | FW 15.90 | Download Firmware 15.90 Release Notes | ||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| X10 | 16.20 | April 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP2 onwards | ||
| X10 | 16.20 | April 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP2 onwards | ||
| X10 | 16.20 | April 2026 | Enhancement | Added support for 76800K baud rate in BACNet MSTP protocol Note – Requires BACNetIP Server dll v5.11 onwards | ||
| X10 | 16.20 | April 2026 | Enhancement | Added support to apply license through SR register and System Menu | ||
| X10 | 16.20 | April 2026 | Bug Fix | Resolved issue where the device displayed an exception when an IEC program was configured with Modbus Master block and the array of structures was enabled | ||
| X10 | 16.20 | April 2026 | Bug Fix | Resolved issue where the device would randomly restart when an IP address was configured with registers and values was set to zero | ||
| X10 | 16.20 | April 2026 | Bug Fix | Resolved issue where the slider was drifting its position when the user held the slider in one position Note – Applicable to only X4 and X10 models | ||
| X10 | 16.20 | April 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP2 onwards | ||
| X10 | 16.20 | April 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| X10 | Download Firmware 16.20 Release Notes | |||||
| X10 | 16.10 | October 2025 | Enhancement | Added support for CPU200 (CPU series) Note: Requires Cscape 10.1 SP1 onwards | ||
| X10 | 16.10 | October 2025 | Enhancement | Added J1939 support Note(s): • This is enabled through the following extension – J2M58-12I15-92C52-38R6D-95OX5 • Requires J1939 license • Requires Cscape 10.2 onwards | ||
| X10 | 16.10 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note: Requires Cscape 10.2 onwards | ||
| X10 | 16.10 | October 2025 | Enhancement | Security improvements: Ethernet ports are opened only if they are configured in Cscape and downloaded to the device. | ||
| X10 | 16.10 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| X10 | 16.10 | October 2025 | Enhancement | Added System Register Bit for the restore operation from logic. Restore operation: %SR164.16 | ||
| X10 | 16.10 | October 2025 | Enhancement | Added System Register Bit for indicating the status of the CAN port Indicates a CAN port error: %SR4.14 | ||
| X10 | 16.10 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS, and it was not displaying any error message on the device. | ||
| X10 | 16.10 | October 2025 | Bug Fix | Resolved - Overlapping of graphic objects wherein the objects were disappearing or were becoming distorted. | ||
| X10 | 16.10 | October 2025 | Bug Fix | Resolved - Ethernet/IP protocol stopped working if the Consumed / Produced configuration exceeded 128 words. | ||
| X10 | 16.10 | October 2025 | Bug Fix | Resolved - Email stopped working when Port 25 was used without authentication, but the response from the email server was switching to TLS. Due to this resolution, if the username and password are not configured with Port 25, the firmware uses the SMTP protocol without authentication, ignoring switching to TLS. | ||
| X10 | 16.10 | October 2025 | Bug Fix | Enhanced filename (RM blocks, PGM) support from 8 characters to 47 characters support | ||
| X10 | 16.10 | October 2025 | Bug Fix | Resolved: Loading a specific PGM file displayed a “BAD Format” error on the device. | ||
| X10 | 16.10 | October 2025 | Bug Fix | Resolved the following issues related to WebMI: • FTP issue: An FTP error was being displayed while publishing webpages after a power cycle. • WebMI pages not loading: Web pages were not being loaded after signing in. | ||
| X10 | 16.10 | October 2025 | Bug Fix | Resolved: OCS-I/O configured with dynamic configuration was not working. | ||
| X10 | 16.10 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 FW Version 48 onwards. | ||
| X10 | 16.10 | October 2025 | Bug Fix | Resolved: The slider was drifting from its position when the user held the slider in one position | ||
| X10 | Download Firmware 16.10 Release Notes | |||||
| X10 | 15.94 | July 2025 | Bug Fix | Resolved: Touching one part of the screen is affecting other parts of the screen. | ||
| X10 | 15.94 | Download Firmware 15.92 Release Notes | ||||
| X10 | 15.92 | May 2025 | Enhancement | “Set Local ID” option is supported for both CsCAN and CANOpen network types (Mantis #7873). Note – Requires Cscape version 10.1 onwards | ||
| X10 | 15.92 | May 2025 | Bug Fix | Resolved: Graphics objects on screen were overlapping the System Menu function keys. | ||
| X10 | 15.92 | May 2025 | Bug Fix | Security improvements were made related to the Ethernet ports. | ||
| X10 | 15.92 | May 2025 | Bug Fix | Resolved: For [some] hardware revisions, touch was not working on the left corner from top to bottom. Note: Applicable to X10 models only. | ||
| X10 | 15.92 | May 2025 | Bug Fix | Resolved: The modified baud rate was not updated in the CANOpen slave device when both master and slave devices were in an operational state. | ||
| X10 | 15.92 | May 2025 | Bug Fix | Resolved: “Delete All” functionality was not working in the Removable Media Object when the user configures the directory as “A:/” | ||
| X10 | 15.92 | May 2025 | Bug Fix | Resolved: Sometimes junk CSV files were created on the MicroSD card when Datalog and serial ports were configured. | ||
| X10 | 15.92 | May 2025 | Bug Fix | Resolved: Auto-populate issue with OCSIO. | ||
| X10 | 15.92 | Download Firmware 15.92 Release Notes | ||||
| X10 | FW 15.90 | February 2025 | Enhancement | Added support for OCSIO DQM602. | ||
| X10 | FW 15.90 | February 2025 | Enhancement | Added retain variables support for Variable-Based Advanced Ladder (VBAL). Note: Requires Cscape version 10.1 onwards. | ||
| X10 | FW 15.90 | February 2025 | Enhancement | Added System Register bit for system menu access. Note: Requires Cscape version 10.1 onwards. | ||
| X10 | FW 15.90 | February 2025 | Enhancement | Added “Alpha Filter Constant” function for analog inputs. Notes: • Requires Cscape version 10.1 onwards • Ranges from 1 – 10 (1 refers to 0.01 filtering and 10 refers to 0.1 filtering) • The lower the value, the heavier the filtering | ||
| X10 | FW 15.90 | February 2025 | Bug Fix | Resolved: The momentary button was behaving as if it was a toggle button when it was placed at the top right corner of the screen. | ||
| X10 | FW 15.90 | February 2025 | Bug Fix | Resolved: Read RM block was reading entire elements/data for an ASCII data type instead of reading only the configured number of elements. | ||
| X10 | FW 15.90 | February 2025 | Bug Fix | Resolved: Time/date object was not displaying data correctly on web pages when the user refreshed the web pages. | ||
| X10 | FW 15.90 | February 2025 | Bug Fix | Resolved: User was seeing a delay of up to 10 seconds when trying to trigger a data write operation in ASCII TCP/IP Client protocol (when the slave device was re-establishing the connection) Notes: • Provided a setting in the protocol network configuration to control the serversion reconnection interval (Fast-2 Seconds, Medium-5 Seconds, Slow-10 Seconds). • This requires ASCII TCP/IP Protocol dll v5.04 onwards. | ||
| X10 | FW 15.90 | Download Firmware 15.90 Release Notes | ||||
XL SERIES
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note: Requires Cscape 10.2 onwards | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Security improvements : Ethernet ports open only if they are configured in Cscape and downloaded to the device. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but is still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Added System Register bit for the restore operation from logic. • Restore operation: %SR164.16 | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Added System Register bit for indicating the status of CAN port • %SR4.14 indicates a CAN port error and may require a power cycle to recover. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | The “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: Loading a .pgm file did not match the exact model of the OCS, and did not display any error message on the device. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Bug Fix | Enhanced filename (RM blocks, PGM) support from 8 characters to 47 characters. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Bug Fix | Improved auto-populate feature in OCSIO Note: Requires CNX116 / CNX100 FW Version 48 onwards. | ||
| XLEe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: The Dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| XLEe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: (ASCII over TCP/IP) Device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| XLEe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: Ethernet/IP protocol stops working if the Consumed / Produced configuration exceeds 128 Words. | ||
| XLEe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved the following issues related to WebMI: • FTP error was being displayed while publishing webpages after a power cycle. • WebMI pages not loading – Web pages were not being loaded after sign in. | ||
| XLE/XLEe | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe only | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe only | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | Download Firmware 15.62 Release Notes | |||||
| XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
| XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
| XLEe only | CSCAN 15.58 | March 2022 | New Feature | Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or | Bootloader | |
| XLEe only | microSD card was removed. (9554/1258) | |||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note: Requires Cscape 10.2 onwards | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Security improvements : Ethernet ports open only if they are configured in Cscape and downloaded to the device. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but is still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Added System Register bit for the restore operation from logic. • Restore operation: %SR164.16 | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | Added System Register bit for indicating the status of CAN port • %SR4.14 indicates a CAN port error and may require a power cycle to recover. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Enhancement | The “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: Loading a .pgm file did not match the exact model of the OCS, and did not display any error message on the device. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Bug Fix | Enhanced filename (RM blocks, PGM) support from 8 characters to 47 characters. | ||
| XLE/XLEe | CSCAN 15.70 | March 2026 | Bug Fix | Improved auto-populate feature in OCSIO Note: Requires CNX116 / CNX100 FW Version 48 onwards. | ||
| XLEe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: The Dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| XLEe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: (ASCII over TCP/IP) Device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| XLEe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: Ethernet/IP protocol stops working if the Consumed / Produced configuration exceeds 128 Words. | ||
| XLEe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved the following issues related to WebMI: • FTP error was being displayed while publishing webpages after a power cycle. • WebMI pages not loading – Web pages were not being loaded after sign in. | ||
| XLE/XLEe | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe only | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe only | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLE/XLEe | Download Firmware 15.62 Release Notes | |||||
| XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
| XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
| XLEe only | CSCAN 15.58 | March 2022 | New Feature | Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or | Bootloader | |
| XLEe only | microSD card was removed. (9554/1258) | |||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | |
|---|---|---|---|---|---|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note: Requires Cscape 10.2 onwards |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Security improvements : Ethernet ports open only if they are configured in Cscape and downloaded to the device. |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but is still in the alarm state, after the alarm returns to normal, the return was not being logged. | |
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Added System Register bit for the restore operation from logic. • Restore operation: %SR164.16 |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Added System Register bit for indicating the status of CAN port • %SR4.14 indicates a CAN port error and may require a power cycle to recover. |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | The “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Bug Fix | Resolved: Loading a .pgm file did not match the exact model of the OCS, and did not display any error message on the device. | |
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Bug Fix | Enhanced filename (RM blocks, PGM) support from 8 characters to 47 characters. | |
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Bug Fix | Improved auto-populate feature in OCSIO Note: Requires CNX116 / CNX100 FW Version 48 onwards. |
|
| XLEe, XLTe Gen 3 only | CSCAN 17.10 | March 2026 | Bug Fix | Resolved: The Dynamically configured IP address was not editable using the System Menu in Idle mode. | |
| XLEe, XLTe Gen 3 only | CSCAN 17.10 | March 2026 | Bug Fix | Resolved: (ASCII over TCP/IP) Device status was not displayed correctly after disconnecting and reconnecting the server. | |
| XLEe, XLTe Gen 3 only | CSCAN 17.10 | March 2026 | Bug Fix | Resolved: Ethernet/IP protocol stops working if the Consumed / Produced configuration exceeds 128 Words. | |
| XLEe, XLTe Gen 3 only | CSCAN 17.10 | March 2026 | Bug Fix | Resolved the following issues related to WebMI: • FTP error was being displayed while publishing webpages after a power cycle. • WebMI pages not loading – Web pages were not being loaded after sign in. |
|
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note: Requires Cscape 10.2 onwards | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Security improvements : Ethernet ports open only if they are configured in Cscape and downloaded to the device. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but is still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Added System Register bit for the restore operation from logic. • Restore operation: %SR164.16 | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Added System Register bit for indicating the status of CAN port • %SR4.14 indicates a CAN port error and may require a power cycle to recover. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | The “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: Loading a .pgm file did not match the exact model of the OCS, and did not display any error message on the device. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Bug Fix | Enhanced filename (RM blocks, PGM) support from 8 characters to 47 characters. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Bug Fix | Improved auto-populate feature in OCSIO Note: Requires CNX116 / CNX100 FW Version 48 onwards. | ||
| XLTe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: The Dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| XLTe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: (ASCII over TCP/IP) Device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| XLTe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: Ethernet/IP protocol stops working if the Consumed / Produced configuration exceeds 128 Words. | ||
| XLTe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved the following issues related to WebMI: • FTP error was being displayed while publishing webpages after a power cycle. • WebMI pages not loading – Web pages were not being loaded after sign in. | ||
| XLT/XLTe | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe only | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe only | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | Download Firmware 15.62 Release Notes | |||||
| XLT/XLTe | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
| XLT/XLTe | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
| XLTe only | CSCAN 15.58 | March 2022 | New Feature | Added support for alternative hardware components. | Bootloader | |
| XLTe only | Download Firmware 15.58 Release Notes | |||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note: Requires Cscape 10.2 onwards | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Security improvements : Ethernet ports open only if they are configured in Cscape and downloaded to the device. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but is still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Added System Register bit for the restore operation from logic. • Restore operation: %SR164.16 | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | Added System Register bit for indicating the status of CAN port • %SR4.14 indicates a CAN port error and may require a power cycle to recover. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Enhancement | The “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: Loading a .pgm file did not match the exact model of the OCS, and did not display any error message on the device. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Bug Fix | Enhanced filename (RM blocks, PGM) support from 8 characters to 47 characters. | ||
| XLT/XLTe | CSCAN 15.70 | March 2026 | Bug Fix | Improved auto-populate feature in OCSIO Note: Requires CNX116 / CNX100 FW Version 48 onwards. | ||
| XLTe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: The Dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| XLTe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: (ASCII over TCP/IP) Device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| XLTe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved: Ethernet/IP protocol stops working if the Consumed / Produced configuration exceeds 128 Words. | ||
| XLTe only | CSCAN 15.70 | March 2026 | Bug Fix | Resolved the following issues related to WebMI: • FTP error was being displayed while publishing webpages after a power cycle. • WebMI pages not loading – Web pages were not being loaded after sign in. | ||
| XLT/XLTe | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe only | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe only | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
| XLT/XLTe | Download Firmware 15.62 Release Notes | |||||
| XLT/XLTe | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
| XLT/XLTe | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
| XLTe only | CSCAN 15.58 | March 2022 | New Feature | Added support for alternative hardware components. | Bootloader | |
| XLTe only | Download Firmware 15.58 Release Notes | |||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | |
|---|---|---|---|---|---|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note: Requires Cscape 10.2 onwards |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Security improvements : Ethernet ports open only if they are configured in Cscape and downloaded to the device. |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but is still in the alarm state, after the alarm returns to normal, the return was not being logged. | |
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Added System Register bit for the restore operation from logic. • Restore operation: %SR164.16 |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | Added System Register bit for indicating the status of CAN port • %SR4.14 indicates a CAN port error and may require a power cycle to recover. |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Enhancement | The “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards |
|
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Bug Fix | Resolved: Loading a .pgm file did not match the exact model of the OCS, and did not display any error message on the device. | |
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Bug Fix | Enhanced filename (RM blocks, PGM) support from 8 characters to 47 characters. | |
| XLE/XLEe, XLT/XLTe Gen 3 | CSCAN 17.10 | March 2026 | Bug Fix | Improved auto-populate feature in OCSIO Note: Requires CNX116 / CNX100 FW Version 48 onwards. |
|
| XLEe, XLTe Gen 3 only | CSCAN 17.10 | March 2026 | Bug Fix | Resolved: The Dynamically configured IP address was not editable using the System Menu in Idle mode. | |
| XLEe, XLTe Gen 3 only | CSCAN 17.10 | March 2026 | Bug Fix | Resolved: (ASCII over TCP/IP) Device status was not displayed correctly after disconnecting and reconnecting the server. | |
| XLEe, XLTe Gen 3 only | CSCAN 17.10 | March 2026 | Bug Fix | Resolved: Ethernet/IP protocol stops working if the Consumed / Produced configuration exceeds 128 Words. | |
| XLEe, XLTe Gen 3 only | CSCAN 17.10 | March 2026 | Bug Fix | Resolved the following issues related to WebMI: • FTP error was being displayed while publishing webpages after a power cycle. • WebMI pages not loading – Web pages were not being loaded after sign in. |
|
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| EXLW | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| EXLW | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| EXLW | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| EXLW | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| EXLW | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| EXLW | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| EXLW | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| EXLW | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| EXLW | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| EXLW | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| XL4, EXL6, EXLW, XL7, EXL10 | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader | |
| XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was able to login via user access object (10016) | Bootloader | |
| XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages (9045) | Bootloader | |
| XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved following issues related to Automatic Recovery procedure - a. Application program mainly the Configuration and Ladder sizes were zero, and the OCS was going to idle mode. b. System settings were not getting restored from the Backup (6206) | Bootloader | |
| XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved rebooting of device continuously after a power cycle if DHCP was enabled in LAN2 (8539) | Bootloader | |
| XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue wherein Modbus client was sending zero value when holding register is not zero (8035) | Bootloader | |
| XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue where CAN2 stops working after several power cycles (8612) | Bootloader | |
| XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) to avoid opening of password dialog when PGM is loaded via SR bits. (8345) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Enhancement | HSC IO filter support added | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue where in whole SD card contents were getting wiped out if RM delete block was configured with "Blank filename" or "only directory mentioned with \" as the last character. (7367/7300) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if the battery fails, license will be valid (for lifetime licenses). (3429) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein conversion blocks were working only for ODD register number and was failing for EVEN register number. (6233) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein device was displaying exception when used Copy CF block – IEC. (7631) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage via web designer model, device displayed Hardfault error. (8288) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue where in Q1 output was not going TRUE after online change. (8713) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue where in Modbus Client protocol stops working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein Automatic Recovery procedure was not working always. (6206) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue when battery was missing and in non-Automatic Restore mode, the application was not getting deleted, and registers displayed some random values. (6207) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein without releasing initial touch on screen, user was able to operate multiple touches with the initial touch being still active. (1241) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup. (7639) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue where alarm history in WebMI was not listing all alarms. (1643) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device (XLPlus) restart to resume communications. (8635) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein when user exits from Online Change mode, CAN port 1 SmartStix were temporarily showing not configured in the status. (9951) | Bootloader | |
| XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader | |
| XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Implemented read only file system. | Bootloader | |
| XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when F-keys tied to switch screen coils, sometimes the F-key would remain held during the screen switch until pressed again. (4668) | Bootloader | |
| XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
| XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when Modbus TCP communication would stop due to DHCP lease time expiring. (6101) | Bootloader | |
| XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when FTP of files to OCS were failing under certain conditions. (4593/4792) | Bootloader | |
| XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when unit would lose communication with Cscape over Ethernet when the unit was left running for multiple days. (4700) | Bootloader | |
| XL15+ | Download Firmware 15.54 Release Notes | |||||
| XL15+ | CSCAN 15.52 | May 2021 | Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. Requires Cscape 9.90 SP4. | Bootloader | |
| XL15+ | CSCAN 15.52 | May 2021 | Enhancement | Enhanced IEC Licensing – Features added. Requires Cscape 9.90 SP4. | Bootloader | |
| XL15+ | CSCAN 15.52 | May 2021 | Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
| XL15+ | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. (2155) | Bootloader | |
| XL15+ | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Cscape was not able to connect to XL+ via ethernet after leaving the unit running for multiple days although pinging was functional. (4700) | Bootloader | |
| XL15+ | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where in NTP server was skipping a day on New Year’s Day. (4910) | Bootloader | |
| XL15+ | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where in navigating to screen configured with objects which had overlapping of data value on legend was causing watch dog trip. (5351) | Bootloader | |
| XL15+ | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working (Port loopback test failed on MJ1, MJ2 and MJ3 ports). (5713) | Bootloader | |
| XL15+ | Download Firmware 15.52 Release Notes | |||||
| XL+ | CSCAN 15.42 | February 2021 | Enhancement | Support has been provided to add user customized keyslide image. | ||
| XL+ | CSCAN 15.42 | February 2021 | Bug Fix | Resolved screen capture issue where the captured images display incorrect colors when viewed on a PC screen. | ||
| XL+ | CSCAN 15.42 | February 2021 | Bug Fix | Resolved an issue where an FTP Failure error message is displayed while publishing webpages (WebMI). | ||
| XL+ | CSCAN 15.42 | February 2021 | Bug Fix | Resolved an issue where the XL+ suffers a system exception under the following conditions: 1. 2nd user is logged in to WebMI webpages 2. 2nd user attempts to access a webpage that has an embedded Alarm History object. 3. Controller is currently displaying the same page | ||
| XL+ | Download Firmware 15.42 Release Notes | |||||
| XL+ | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | Cscape 9.90 SP3 | |
| XL+ | CSCAN 15.40 | July 2020 | Enhancement | DHCP and DNS Support | Cscape 9.90 SP3 | |
| XL+ | CSCAN 15.40 | July 2020 | Enhancement | MQTT - Sparkplug (licensed feature) | Cscape 9.90 SP3 | |
| XL+ | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | Cscape 9.90 SP3 | |
| XL+ | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
| XL+ | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
| XL+ | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
| XL+ | CSCAN 15.40 | July 2020 | Bug Fix | Fixed FPGA error (XL+ with EipcClient protocol 4.00 would not download to controller) | Cscape 9.90 SP3 | |
| XL+ | Download Firmware 15.40 Release Notes | |||||
| XL+ | CSCAN 15.32 | February 2020 | Enhancement | Wi-Fi Support | ||
| XL+ | CSCAN 15.32 | February 2020 | Enhancement | Live graphics update support | ||
| XL+ | CSCAN 15.32 | February 2020 | Enhancement | Screen Mirroring (Dual Display) support using mini display port connector | ||
| XL+ | CSCAN 15.32 | February 2020 | Enhancement | Text wrap on Button text | ||
| XL+ | CSCAN 15.32 | February 2020 | Enhancement | New Gauge Needles | ||
| XL+ | CSCAN 15.32 | February 2020 | Enhancement | Set CAN ID function block | ||
| XL+ | CSCAN 15.32 | February 2020 | Enhancement | .Array move with datatypes and in advanced ladder with tags | ||
| XL+ | CSCAN 15.32 | February 2020 | Enhancement | Added support for 500K and 1M baud in J1939 protocol | ||
| XL+ | CSCAN 15.32 | February 2020 | Enhancement | NTP protocol for XL+ | ||
| XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Font colors for buttons on XL+ | ||
| XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Word security is misspelled on screen while downloading | ||
| XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Improved compatibility with microSD cards | ||
| XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Corrected EGD issue | ||
| XL+ | CSCAN 15.32 | February 2020 | Bug Fix | First letter of attached filename being cut off after email send. | ||
| XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Artifacts on screen objects with non-visible screen objects overlayed | ||
| XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Graphic display issue on XL+ featuring text overlayed on bitmaps and screen jumps | ||
| XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Corrected issue where unit occasionally loses program if Load Program is following immediately by power cycle. | ||
| XL+ | NOTE: Firmware 15.32 is required for hardware CD for Model 5 only. Older firmware will not function on this newer hardware if thermocouple inputs are used. | |||||
| XL+ | Download Firmware 15.32 Release Notes | |||||
XL PRIME SERIES
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Implemented new retentive timer and counter blocks that retain accumulator values after a power cycle Note – • Applicable to Enhanced IEC only • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support to HSC840 and NTC800 OCS-I/O modules Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added “Use as Default Gateway” option Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein email stopped working when used Secomea Email Relay on port 25 without authentication | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the device displayed an exception when the program was configured with a Modbus Master block and array of structures was enabled Note – Applicable to IEC and Enhanced IEC blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the ASCII TCP/IP Server protocol did not function when configured with registers beyond %R10000 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where Ethernet status TX/RX bits were not shown as active when MQTT and OCS360 were enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where a .PGM file placed inside a folder was not loading | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein the device displayed system exception when devices with dual ports were configured with downloadable protocols having large scan list entries for two or more ports | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the LAN configuration status read a value of zero when configured with registers beyond %R8193 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue that caused the device to enter Idle mode after downloading a CANOpen Blocks program with the “Array of Structures” option enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.32 | March 3, 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards | Requires Cscape 10.2 onward | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Enhanced IEC only Resolved - Clearing alarms from the alarm history object was giving a system exception. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The device displayed a system exception when triggered by MQTT without running a broker. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program. • Triggering an alarm was displaying a different alarm on the device. • Triggering an alarm was displaying an alarm message multiple times on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmware version 48 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: System Register bit for System Menu access. Note: Requires Cscape version 10.1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added support to apply license through System Register and System Menu. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Bitmaps were not displayed on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types. Note: This requires Cscape 10 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Implemented new retentive timer and counter blocks that retain accumulator values after a power cycle Note – • Applicable to Enhanced IEC only • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support to HSC840 and NTC800 OCS-I/O modules Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added “Use as Default Gateway” option Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein email stopped working when used Secomea Email Relay on port 25 without authentication | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the device displayed an exception when the program was configured with a Modbus Master block and array of structures was enabled Note – Applicable to IEC and Enhanced IEC blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the ASCII TCP/IP Server protocol did not function when configured with registers beyond %R10000 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where Ethernet status TX/RX bits were not shown as active when MQTT and OCS360 were enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where a .PGM file placed inside a folder was not loading | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein the device displayed system exception when devices with dual ports were configured with downloadable protocols having large scan list entries for two or more ports | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the LAN configuration status read a value of zero when configured with registers beyond %R8193 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue that caused the device to enter Idle mode after downloading a CANOpen Blocks program with the “Array of Structures” option enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.32 | March 3, 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards | Requires Cscape 10.2 onward | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Enhanced IEC only Resolved - Clearing alarms from the alarm history object was giving a system exception. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The device displayed a system exception when triggered by MQTT without running a broker. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program. • Triggering an alarm was displaying a different alarm on the device. • Triggering an alarm was displaying an alarm message multiple times on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmware version 48 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: System Register bit for System Menu access. Note: Requires Cscape version 10.1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added support to apply license through System Register and System Menu. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Bitmaps were not displayed on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types. Note: This requires Cscape 10 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Implemented new retentive timer and counter blocks that retain accumulator values after a power cycle Note – • Applicable to Enhanced IEC only • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support to HSC840 and NTC800 OCS-I/O modules Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added “Use as Default Gateway” option Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein email stopped working when used Secomea Email Relay on port 25 without authentication | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the device displayed an exception when the program was configured with a Modbus Master block and array of structures was enabled Note – Applicable to IEC and Enhanced IEC blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the ASCII TCP/IP Server protocol did not function when configured with registers beyond %R10000 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where Ethernet status TX/RX bits were not shown as active when MQTT and OCS360 were enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where a .PGM file placed inside a folder was not loading | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein the device displayed system exception when devices with dual ports were configured with downloadable protocols having large scan list entries for two or more ports | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the LAN configuration status read a value of zero when configured with registers beyond %R8193 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue that caused the device to enter Idle mode after downloading a CANOpen Blocks program with the “Array of Structures” option enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.32 | March 3, 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards | Requires Cscape 10.2 onward | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Enhanced IEC only Resolved - Clearing alarms from the alarm history object was giving a system exception. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The device displayed a system exception when triggered by MQTT without running a broker. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program. • Triggering an alarm was displaying a different alarm on the device. • Triggering an alarm was displaying an alarm message multiple times on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmware version 48 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: System Register bit for System Menu access. Note: Requires Cscape version 10.1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added support to apply license through System Register and System Menu. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Bitmaps were not displayed on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types. Note: This requires Cscape 10 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Implemented new retentive timer and counter blocks that retain accumulator values after a power cycle Note – • Applicable to Enhanced IEC only • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support to HSC840 and NTC800 OCS-I/O modules Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added “Use as Default Gateway” option Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein email stopped working when used Secomea Email Relay on port 25 without authentication | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the device displayed an exception when the program was configured with a Modbus Master block and array of structures was enabled Note – Applicable to IEC and Enhanced IEC blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the ASCII TCP/IP Server protocol did not function when configured with registers beyond %R10000 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where Ethernet status TX/RX bits were not shown as active when MQTT and OCS360 were enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where a .PGM file placed inside a folder was not loading | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein the device displayed system exception when devices with dual ports were configured with downloadable protocols having large scan list entries for two or more ports | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the LAN configuration status read a value of zero when configured with registers beyond %R8193 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue that caused the device to enter Idle mode after downloading a CANOpen Blocks program with the “Array of Structures” option enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.32 | March 3, 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards | Requires Cscape 10.2 onward | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Enhanced IEC only Resolved - Clearing alarms from the alarm history object was giving a system exception. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The device displayed a system exception when triggered by MQTT without running a broker. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program. • Triggering an alarm was displaying a different alarm on the device. • Triggering an alarm was displaying an alarm message multiple times on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmware version 48 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: System Register bit for System Menu access. Note: Requires Cscape version 10.1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added support to apply license through System Register and System Menu. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Bitmaps were not displayed on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types. Note: This requires Cscape 10 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Implemented new retentive timer and counter blocks that retain accumulator values after a power cycle Note – • Applicable to Enhanced IEC only • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support to HSC840 and NTC800 OCS-I/O modules Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added “Use as Default Gateway” option Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein email stopped working when used Secomea Email Relay on port 25 without authentication | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the device displayed an exception when the program was configured with a Modbus Master block and array of structures was enabled Note – Applicable to IEC and Enhanced IEC blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the ASCII TCP/IP Server protocol did not function when configured with registers beyond %R10000 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where Ethernet status TX/RX bits were not shown as active when MQTT and OCS360 were enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where a .PGM file placed inside a folder was not loading | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein the device displayed system exception when devices with dual ports were configured with downloadable protocols having large scan list entries for two or more ports | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the LAN configuration status read a value of zero when configured with registers beyond %R8193 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue that caused the device to enter Idle mode after downloading a CANOpen Blocks program with the “Array of Structures” option enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.32 | March 3, 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards | Requires Cscape 10.2 onward | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Enhanced IEC only Resolved - Clearing alarms from the alarm history object was giving a system exception. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The device displayed a system exception when triggered by MQTT without running a broker. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program. • Triggering an alarm was displaying a different alarm on the device. • Triggering an alarm was displaying an alarm message multiple times on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmware version 48 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: System Register bit for System Menu access. Note: Requires Cscape version 10.1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added support to apply license through System Register and System Menu. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Bitmaps were not displayed on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types. Note: This requires Cscape 10 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Implemented new retentive timer and counter blocks that retain accumulator values after a power cycle Note – • Applicable to Enhanced IEC only • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support to HSC840 and NTC800 OCS-I/O modules Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added “Use as Default Gateway” option Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein email stopped working when used Secomea Email Relay on port 25 without authentication | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the device displayed an exception when the program was configured with a Modbus Master block and array of structures was enabled Note – Applicable to IEC and Enhanced IEC blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the ASCII TCP/IP Server protocol did not function when configured with registers beyond %R10000 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where Ethernet status TX/RX bits were not shown as active when MQTT and OCS360 were enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where a .PGM file placed inside a folder was not loading | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein the device displayed system exception when devices with dual ports were configured with downloadable protocols having large scan list entries for two or more ports | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the LAN configuration status read a value of zero when configured with registers beyond %R8193 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue that caused the device to enter Idle mode after downloading a CANOpen Blocks program with the “Array of Structures” option enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.32 | March 3, 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards | Requires Cscape 10.2 onward | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Enhanced IEC only Resolved - Clearing alarms from the alarm history object was giving a system exception. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The device displayed a system exception when triggered by MQTT without running a broker. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program. • Triggering an alarm was displaying a different alarm on the device. • Triggering an alarm was displaying an alarm message multiple times on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmware version 48 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: System Register bit for System Menu access. Note: Requires Cscape version 10.1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Enhancement | Added support to apply license through System Register and System Menu. Note: Requires Cscape version 10.1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Bitmaps were not displayed on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types. Note: This requires Cscape 10 SP1 onwards. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Implemented new retentive timer and counter blocks that retain accumulator values after a power cycle Note – • Applicable to Enhanced IEC only • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support to HSC840 and NTC800 OCS-I/O modules Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added “Use as Default Gateway” option Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein email stopped working when used Secomea Email Relay on port 25 without authentication | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the device displayed an exception when the program was configured with a Modbus Master block and array of structures was enabled Note – Applicable to IEC and Enhanced IEC blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the ASCII TCP/IP Server protocol did not function when configured with registers beyond %R10000 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where Ethernet status TX/RX bits were not shown as active when MQTT and OCS360 were enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where a .PGM file placed inside a folder was not loading | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein the device displayed system exception when devices with dual ports were configured with downloadable protocols having large scan list entries for two or more ports | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the LAN configuration status read a value of zero when configured with registers beyond %R8193 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue that caused the device to enter Idle mode after downloading a CANOpen Blocks program with the “Array of Structures” option enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards | Requires Cscape 10.2 onward | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Enhanced IEC only Resolved - Clearing alarms from the alarm history object was giving a system exception. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The device displayed a system exception when triggered by MQTT without running a broker. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program. • Triggering an alarm was displaying a different alarm on the device. • Triggering an alarm was displaying an alarm message multiple times on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmware version 48 onwards. | ||
| Prime XL10W | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. | ||
| Prime XL10W | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | ||
| Prime XL10W | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | ||
| Prime XL10W | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | ||
| Prime XL10W | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | ||
| Prime XL10W | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | ||
| Prime XL10W | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. | ||
| Prime XL10W | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards | ||
| Prime XL10W | 17.10 | February 2025 | Enhancement | Added: System Register bit for System Menu access. Note: Requires Cscape version 10.1 onwards. | ||
| Prime XL10W | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | ||
| Prime XL10W | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| Prime XL10W | 17.10 | February 2025 | Enhancement | Added support to apply license through System Register and System Menu. Note: Requires Cscape version 10.1 onwards | ||
| Prime XL10W | 17.10 | February 2025 | Bug Fix | Resolved: Bitmaps were not displayed on the device. | ||
| Prime XL10W | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | ||
| Prime XL10W | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | ||
| Prime XL10W | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | ||
| Prime XL10W | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types. Note: This requires Cscape 10 SP1 onwards. | ||
| Prime XL10W | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | ||
| Prime XL10W | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | ||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added WebMI 2.0 support Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support for ASCII username and password Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Implemented new retentive timer and counter blocks that retain accumulator values after a power cycle Note – • Applicable to Enhanced IEC only • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added support to HSC840 and NTC800 OCS-I/O modules Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Enhancement | Added “Use as Default Gateway” option Note – Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein email stopped working when used Secomea Email Relay on port 25 without authentication | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the device displayed an exception when the program was configured with a Modbus Master block and array of structures was enabled Note – Applicable to IEC and Enhanced IEC blocks | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the ASCII TCP/IP Server protocol did not function when configured with registers beyond %R10000 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where Ethernet status TX/RX bits were not shown as active when MQTT and OCS360 were enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where a .PGM file placed inside a folder was not loading | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where GE SNP protocol was not working over RS-485 full duplex communication Note – • Requires SNP dll v5.02 onwards • Requires Cscape 10.2 SP1 onwards | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue wherein the device displayed system exception when devices with dual ports were configured with downloadable protocols having large scan list entries for two or more ports | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where the LAN configuration status read a value of zero when configured with registers beyond %R8193 | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue where negative Y-axis values were not plotted correctly in trend graphs | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.40 | March 18, 2026 | Bug Fix | Resolved issue that caused the device to enter Idle mode after downloading a CANOpen Blocks program with the “Array of Structures” option enabled | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards | Requires Cscape 10.2 onward | |
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - After publishing for a few minutes to OCS360, the device went into Idle mode and showed a logic error in the diagnostics. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Issues related to the overlapping of graphic objects as objects had been disappearing or becoming distorted. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Enhanced IEC only Resolved - Clearing alarms from the alarm history object was giving a system exception. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The device displayed a system exception when triggered by MQTT without running a broker. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – The alarm was configured with a Boolean array variable in an Enhanced IEC program. • Triggering an alarm was displaying a different alarm on the device. • Triggering an alarm was displaying an alarm message multiple times on the device. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - An ASCII over TCP/IP issue in which the device status was not displayed correctly after disconnecting and reconnecting the server. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved – A system exception was displayed on the slave device when the array of length of holding registers and input registers of the Enhanced IEC Modbus Map slave or Modbus Map Extended slave block was changed and downloaded to the slave device; when both master and slave devices are communicating. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3, and 4. | ||
| Prime X5, XL4, XL6, XLW, XL7, XL10, XL10W, XL15 | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmware version 48 onwards. | ||
| Prime XL15 | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. | ||
| Prime XL15 | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | ||
| Prime XL15 | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | ||
| Prime XL15 | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | ||
| Prime XL15 | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | ||
| Prime XL15 | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | ||
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. | ||
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards | ||
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added: System Register bit for System Menu access. Note: Requires Cscape version 10.1 onwards. | ||
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | ||
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards | ||
| Prime XL15 | 17.10 | February 2025 | Enhancement | Added support to apply license through System Register and System Menu. Note: Requires Cscape version 10.1 onwards | ||
| Prime XL15 | 17.10 | February 2025 | Bug Fix | Resolved: Bitmaps were not displayed on the device. | ||
| Prime XL15 | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | ||
| Prime XL15 | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | ||
| Prime XL15 | 17.06 | November 2024 | Enhancement | Added XL10W prime support. | ||
| Prime XL15 | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types. Note: This requires Cscape 10 SP1 onwards. | ||
| Prime XL15 | 17.06 | November 2024 | Enhancement | The following enhancements have been added to MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation | ||
| Prime XL15 | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. | ||
| Prime XL15 | CSCAN 17.04 | September 2024 | Bug Fix | Resolved: USB Type C communication not working on XL15 Prime model. | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
| Prime XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
CANVAS SERIES
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | |
|---|---|---|---|---|---|
| Canvas 4, 5, 7, 7D, 10D | 17.32 | March 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added CPU300 model support. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added the following system register bits for Save PGM Fail and Load PGM fail. SR164.11 – Save PGM fail bit SR164.12 – Load PGM fail bit |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The screen was loading objects with default settings first, and then followed by the Enhanced Display Attributes structures configured | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Button touch was not working if the button visibility was configured as OFF and showed the icon option was unchecked. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The way the multi-position selector switch works. • For Example – A three-position selector switch works from 0-1-2, 0-1-2 positions to 0-1-2, 2-1-0 positions when operated. • Note - Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The following gesture changes are in the menu object page: • The left side of the menu object page is mainly used for scrolling purpose - touch will not select any menu item. • The right side of the menu object page is for scrolling and selecting / editing purposes. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The mouse scroll was not working when using an external wired mouse for operations. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block is in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (Applies to 3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarm acknowledgment was not working in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Improved the response time of toggle buttons when a greater number of buttons were configured in a screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Modbus TCP/IP configured with external registers was not working for a program created in Cscape 9.90 and downloaded from Cscape 10. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarms were not being displayed on the summary and history list after 170 alarms were shown in the history list in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – Occasionally, System Menu pages were displayed when the System Key is pressed, even though the System Lock was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3 and 4 |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmwear version 48 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Data entered by the user was not displayed correctly for a few conditions with a decimal point if the user did not enter a preceding zero. For example, if the user enters 10.0, it will be displayed as 0.100 on the display. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Pop-up alarm banner touch was not working correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The "RUN" LED displayed a flashing light in the pop-up status window after downloading an application, with pop-up status enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Live graphics update was downloading pages that were not changed. This has been changed to downloading only the changed screens. Note: The loading indicator remains visible on the screen during the Live Graphics Update, but the time it takes to return to the normal screen depends on the number of modified objects on the screen for download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device was getting stuck at the "Initiating Autoload" page when the user does a make clone, clears the application, enables Autoload/autorun options, and power cycles the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Provision to slide in (Show/Hide) zoom in/out and cursor control on the trends and graph objects. Note: Requires Cscape version 10.1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added System register bit for System Menu access (Mantis #13895) Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Keypad and Spinner options in the text table graphic object configuration. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The upper case for characters was enabled after the user enters “.“ (dot) on the device keyboard. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing a user screen with logic was not changing the screen on webpages. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: %SR182 (Active alarm) bits were not updated correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: User Login object was not accepting inputs from the physical keyboard on webpages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Controller displayed a system exception when the unit was switched to RUN mode from an onscreen object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: WebMI Plus was not working in portrait mode on mobile devices. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Support was added to change the default pen width for Trends and Graph objects. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added support for USB video inputs. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types Note: This requires Cscape 10 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | The following enhancements have been made in MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased the maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Customized slide keys were not being updated by the replace system graphics option and during firmware updates. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: The touch area to bring out the F-Keys in the upper, right corner was too big which was interfering with touchscreen buttons in that area. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Canvas 10D Only Resolved: Booting issue in which the ambient temperature was very hot (60C) / cold (-10C) for Canvas 10D. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | |
| Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | |
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | |
|---|---|---|---|---|---|
| Canvas 4, 5, 7, 7D, 10D | 17.32 | March 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added CPU300 model support. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added the following system register bits for Save PGM Fail and Load PGM fail. SR164.11 – Save PGM fail bit SR164.12 – Load PGM fail bit |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The screen was loading objects with default settings first, and then followed by the Enhanced Display Attributes structures configured | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Button touch was not working if the button visibility was configured as OFF and showed the icon option was unchecked. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The way the multi-position selector switch works. • For Example – A three-position selector switch works from 0-1-2, 0-1-2 positions to 0-1-2, 2-1-0 positions when operated. • Note - Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The following gesture changes are in the menu object page: • The left side of the menu object page is mainly used for scrolling purpose - touch will not select any menu item. • The right side of the menu object page is for scrolling and selecting / editing purposes. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The mouse scroll was not working when using an external wired mouse for operations. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block is in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (Applies to 3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarm acknowledgment was not working in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Improved the response time of toggle buttons when a greater number of buttons were configured in a screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Modbus TCP/IP configured with external registers was not working for a program created in Cscape 9.90 and downloaded from Cscape 10. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarms were not being displayed on the summary and history list after 170 alarms were shown in the history list in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – Occasionally, System Menu pages were displayed when the System Key is pressed, even though the System Lock was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3 and 4 |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmwear version 48 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Data entered by the user was not displayed correctly for a few conditions with a decimal point if the user did not enter a preceding zero. For example, if the user enters 10.0, it will be displayed as 0.100 on the display. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Pop-up alarm banner touch was not working correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The "RUN" LED displayed a flashing light in the pop-up status window after downloading an application, with pop-up status enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Live graphics update was downloading pages that were not changed. This has been changed to downloading only the changed screens. Note: The loading indicator remains visible on the screen during the Live Graphics Update, but the time it takes to return to the normal screen depends on the number of modified objects on the screen for download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device was getting stuck at the "Initiating Autoload" page when the user does a make clone, clears the application, enables Autoload/autorun options, and power cycles the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Provision to slide in (Show/Hide) zoom in/out and cursor control on the trends and graph objects. Note: Requires Cscape version 10.1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added System register bit for System Menu access (Mantis #13895) Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Keypad and Spinner options in the text table graphic object configuration. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The upper case for characters was enabled after the user enters “.“ (dot) on the device keyboard. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing a user screen with logic was not changing the screen on webpages. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: %SR182 (Active alarm) bits were not updated correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: User Login object was not accepting inputs from the physical keyboard on webpages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Controller displayed a system exception when the unit was switched to RUN mode from an onscreen object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: WebMI Plus was not working in portrait mode on mobile devices. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Support was added to change the default pen width for Trends and Graph objects. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added support for USB video inputs. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types Note: This requires Cscape 10 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | The following enhancements have been made in MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased the maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Customized slide keys were not being updated by the replace system graphics option and during firmware updates. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: The touch area to bring out the F-Keys in the upper, right corner was too big which was interfering with touchscreen buttons in that area. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Canvas 10D Only Resolved: Booting issue in which the ambient temperature was very hot (60C) / cold (-10C) for Canvas 10D. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | |
| Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | |
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | |
|---|---|---|---|---|---|
| Canvas 4, 5, 7, 7D, 10D | 17.32 | March 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added CPU300 model support. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added the following system register bits for Save PGM Fail and Load PGM fail. SR164.11 – Save PGM fail bit SR164.12 – Load PGM fail bit |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The screen was loading objects with default settings first, and then followed by the Enhanced Display Attributes structures configured | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Button touch was not working if the button visibility was configured as OFF and showed the icon option was unchecked. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The way the multi-position selector switch works. • For Example – A three-position selector switch works from 0-1-2, 0-1-2 positions to 0-1-2, 2-1-0 positions when operated. • Note - Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The following gesture changes are in the menu object page: • The left side of the menu object page is mainly used for scrolling purpose - touch will not select any menu item. • The right side of the menu object page is for scrolling and selecting / editing purposes. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The mouse scroll was not working when using an external wired mouse for operations. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block is in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (Applies to 3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarm acknowledgment was not working in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Improved the response time of toggle buttons when a greater number of buttons were configured in a screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Modbus TCP/IP configured with external registers was not working for a program created in Cscape 9.90 and downloaded from Cscape 10. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarms were not being displayed on the summary and history list after 170 alarms were shown in the history list in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – Occasionally, System Menu pages were displayed when the System Key is pressed, even though the System Lock was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3 and 4 |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmwear version 48 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Data entered by the user was not displayed correctly for a few conditions with a decimal point if the user did not enter a preceding zero. For example, if the user enters 10.0, it will be displayed as 0.100 on the display. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Pop-up alarm banner touch was not working correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The "RUN" LED displayed a flashing light in the pop-up status window after downloading an application, with pop-up status enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Live graphics update was downloading pages that were not changed. This has been changed to downloading only the changed screens. Note: The loading indicator remains visible on the screen during the Live Graphics Update, but the time it takes to return to the normal screen depends on the number of modified objects on the screen for download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device was getting stuck at the "Initiating Autoload" page when the user does a make clone, clears the application, enables Autoload/autorun options, and power cycles the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Provision to slide in (Show/Hide) zoom in/out and cursor control on the trends and graph objects. Note: Requires Cscape version 10.1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added System register bit for System Menu access (Mantis #13895) Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Keypad and Spinner options in the text table graphic object configuration. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The upper case for characters was enabled after the user enters “.“ (dot) on the device keyboard. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing a user screen with logic was not changing the screen on webpages. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: %SR182 (Active alarm) bits were not updated correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: User Login object was not accepting inputs from the physical keyboard on webpages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Controller displayed a system exception when the unit was switched to RUN mode from an onscreen object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: WebMI Plus was not working in portrait mode on mobile devices. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Support was added to change the default pen width for Trends and Graph objects. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added support for USB video inputs. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types Note: This requires Cscape 10 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | The following enhancements have been made in MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased the maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Customized slide keys were not being updated by the replace system graphics option and during firmware updates. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: The touch area to bring out the F-Keys in the upper, right corner was too big which was interfering with touchscreen buttons in that area. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Canvas 10D Only Resolved: Booting issue in which the ambient temperature was very hot (60C) / cold (-10C) for Canvas 10D. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | |
| Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | |
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | |
|---|---|---|---|---|---|
| Canvas 4, 5, 7, 7D, 10D | 17.32 | March 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added CPU300 model support. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added the following system register bits for Save PGM Fail and Load PGM fail. SR164.11 – Save PGM fail bit SR164.12 – Load PGM fail bit |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The screen was loading objects with default settings first, and then followed by the Enhanced Display Attributes structures configured | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Button touch was not working if the button visibility was configured as OFF and showed the icon option was unchecked. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The way the multi-position selector switch works. • For Example – A three-position selector switch works from 0-1-2, 0-1-2 positions to 0-1-2, 2-1-0 positions when operated. • Note - Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The following gesture changes are in the menu object page: • The left side of the menu object page is mainly used for scrolling purpose - touch will not select any menu item. • The right side of the menu object page is for scrolling and selecting / editing purposes. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The mouse scroll was not working when using an external wired mouse for operations. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block is in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (Applies to 3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarm acknowledgment was not working in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Improved the response time of toggle buttons when a greater number of buttons were configured in a screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Modbus TCP/IP configured with external registers was not working for a program created in Cscape 9.90 and downloaded from Cscape 10. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarms were not being displayed on the summary and history list after 170 alarms were shown in the history list in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – Occasionally, System Menu pages were displayed when the System Key is pressed, even though the System Lock was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3 and 4 |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmwear version 48 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Data entered by the user was not displayed correctly for a few conditions with a decimal point if the user did not enter a preceding zero. For example, if the user enters 10.0, it will be displayed as 0.100 on the display. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Pop-up alarm banner touch was not working correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The "RUN" LED displayed a flashing light in the pop-up status window after downloading an application, with pop-up status enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Live graphics update was downloading pages that were not changed. This has been changed to downloading only the changed screens. Note: The loading indicator remains visible on the screen during the Live Graphics Update, but the time it takes to return to the normal screen depends on the number of modified objects on the screen for download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device was getting stuck at the "Initiating Autoload" page when the user does a make clone, clears the application, enables Autoload/autorun options, and power cycles the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Provision to slide in (Show/Hide) zoom in/out and cursor control on the trends and graph objects. Note: Requires Cscape version 10.1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added System register bit for System Menu access (Mantis #13895) Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Keypad and Spinner options in the text table graphic object configuration. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The upper case for characters was enabled after the user enters “.“ (dot) on the device keyboard. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing a user screen with logic was not changing the screen on webpages. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: %SR182 (Active alarm) bits were not updated correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: User Login object was not accepting inputs from the physical keyboard on webpages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Controller displayed a system exception when the unit was switched to RUN mode from an onscreen object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: WebMI Plus was not working in portrait mode on mobile devices. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Support was added to change the default pen width for Trends and Graph objects. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added support for USB video inputs. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types Note: This requires Cscape 10 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | The following enhancements have been made in MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased the maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Customized slide keys were not being updated by the replace system graphics option and during firmware updates. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: The touch area to bring out the F-Keys in the upper, right corner was too big which was interfering with touchscreen buttons in that area. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Canvas 10D Only Resolved: Booting issue in which the ambient temperature was very hot (60C) / cold (-10C) for Canvas 10D. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | |
| Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | |
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | |
|---|---|---|---|---|---|
| Canvas 4, 5, 7, 7D, 10D | 17.32 | March 2026 | Bug Fix | Resolved: Device boot-up issue at cold temperatures. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added CPU300 model support. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added “OCSIO Base Identification” feature, including the capability to trigger it from the System Menu. Note : Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added OCS360 System Menu Pages | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Enhancements were made in the boot-up message by displaying the boot-up messages in a single screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Security Improvement Ethernet ports are open only if they are configured in Cscape and downloaded to the device. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added logging of “return” state alarms, wherein if the alarm was acknowledged, but still in the alarm state, after the alarm returns to normal, the return was not being logged. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added the following system register bits for Save PGM Fail and Load PGM fail. SR164.11 – Save PGM fail bit SR164.12 – Load PGM fail bit |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Enhancement | Added system register bit for restore operation from logic: %SR164.16 – Restore operation | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Loading a .pgm file did not match the exact model of the OCS and was not displaying an error message on the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Playing certain video files having non-standard resolution resulted in the shifting of the video towards the right of the video object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The screen was loading objects with default settings first, and then followed by the Enhanced Display Attributes structures configured | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Button touch was not working if the button visibility was configured as OFF and showed the icon option was unchecked. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - LAN2 data was spilling onto LAN1 data registers when using EtherNet/IP on both LAN1 and LAN2. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Email sending using a cell modem was not working after restoring a signal, which resulted in a send failure. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The dynamically configured IP address was not editable using the System Menu in Idle mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The Ethernet/IP protocol stops working if the Consumed/Produced configuration exceeds 128 words. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The way the multi-position selector switch works. • For Example – A three-position selector switch works from 0-1-2, 0-1-2 positions to 0-1-2, 2-1-0 positions when operated. • Note - Requires Cscape 10.2 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - The following gesture changes are in the menu object page: • The left side of the menu object page is mainly used for scrolling purpose - touch will not select any menu item. • The right side of the menu object page is for scrolling and selecting / editing purposes. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – The mouse scroll was not working when using an external wired mouse for operations. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Optimized the WI-FI System Menu page, wherein opening the WI-FI System Menu page was increasing the scan rate slightly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved the following issues related to the CANOpen protocol: • Resolved - Set NMT block for self-node was not working in the CAN2 port for an Enhanced IEC program. • Resolved – The device was displaying a system exception when triggered “CANopen Receive Emergency Device” CANOpen block is in an Enhanced IEC program. • Resolved - The device was displaying a system exception when downloading the CANOpen program while Array Of structures is enabled. Workaround (Applies to 3rd bullet only): Power cycle the device and redownload the program for an Enhanced IEC program. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarm acknowledgment was not working in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Improved the response time of toggle buttons when a greater number of buttons were configured in a screen. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Modbus TCP/IP configured with external registers was not working for a program created in Cscape 9.90 and downloaded from Cscape 10. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Alarms were not being displayed on the summary and history list after 170 alarms were shown in the history list in WebMI Plus pages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved – Occasionally, System Menu pages were displayed when the System Key is pressed, even though the System Lock was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Data from the slave was not being read when there were multiple MODBUS blocks Do requests and old user blocks were used in the same program with the same port being configured in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Resolved - Analog Input values were fluctuating. Note: Applies only to Canvas 7D / Canvas 10D with Models 2, 3 and 4 |
|
| Canvas 4, 5, 7, 7D, 10D | 17.30 | October 2025 | Bug Fix | Improved auto-populate feature in OCS-I/O. Note: Requires CNX116 / CNX100 firmwear version 48 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added system register support to enable and disable DHCP • SR235.1 - DHCP1 (0 - Disable and 1 - Enable) • SR235.2 - DHCP2 (0 - Disable and 1 - Enable) Note: Requires Cscape 10.1 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Enhancement | Added security enhancement for adding a device in OCS360. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Data entered by the user was not displayed correctly for a few conditions with a decimal point if the user did not enter a preceding zero. For example, if the user enters 10.0, it will be displayed as 0.100 on the display. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Pop-up alarm banner touch was not working correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The "RUN" LED displayed a flashing light in the pop-up status window after downloading an application, with pop-up status enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: Live graphics update was downloading pages that were not changed. This has been changed to downloading only the changed screens. Note: The loading indicator remains visible on the screen during the Live Graphics Update, but the time it takes to return to the normal screen depends on the number of modified objects on the screen for download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The screen capture for video streaming was not working. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: A system exception was being displayed when the power flow was enabled to the SDO Receive EMC Device Block in an Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device displayed a system exception when Access Point mode was selected in Wi-Fi configuration through the System Menu and modified the Access Point mode name. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The device was getting stuck at the "Initiating Autoload" page when the user does a make clone, clears the application, enables Autoload/autorun options, and power cycles the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.20 | May 2025 | Bug Fix | Resolved: The ASCII TCP/IP Client device status register was toggling continuously with values 45 and 0 when no server was connected. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: OCS360 support. Note(s) • Requires Cscape version 10.1 onwards • OCS360 status information is now consistent with MQTT. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Provision to slide in (Show/Hide) zoom in/out and cursor control on the trends and graph objects. Note: Requires Cscape version 10.1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Support for multiple USB video streaming. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added System register bit for System Menu access (Mantis #13895) Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added Security Improvements: Ethernet ports are opened only if configured in Cscape and downloaded to the device. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: “Set Local ID” option is supported for both CsCAN and CANOpen network types. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Enhancement | Added: Keypad and Spinner options in the text table graphic object configuration. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The upper case for characters was enabled after the user enters “.“ (dot) on the device keyboard. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: The device was not sending the NMT start command to CANOpen devices after powering up. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing a user screen with logic was not changing the screen on webpages. Note: Requires Cscape version 10.1 onwards |
|
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Forcing was not working when the unit was placed in debug mode. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: %SR182 (Active alarm) bits were not updated correctly. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: User Login object was not accepting inputs from the physical keyboard on webpages. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: Controller displayed a system exception when the unit was switched to RUN mode from an onscreen object. | |
| Canvas 4, 5, 7, 7D, 10D | 17.10 | February 2025 | Bug Fix | Resolved: WebMI Plus was not working in portrait mode on mobile devices. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Support was added to change the default pen width for Trends and Graph objects. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added support for USB video inputs. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | Added new blocks STRINGTOUARRAY and UARRAYTOSTRING in Enhanced IEC to support USINT data types Note: This requires Cscape 10 SP1 onwards. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Enhancement | The following enhancements have been made in MQTT Sparkplug: • Increased store-and-forward queue length from 256 to 1024 • Increased the maximum publish topic size to 256 and 128 metrics per topic • Added Auto Reconnect enable/disable with configurable timeout • Added the ability to choose if a metric should be buffered or not in a store-and-forward situation |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Following a firmware update, the netmask changed to 0.0.0.0 instead of 255.255.255.0 Note • When the netmask is entered as 0.0.0.0 from the System Menu, it is automatically changed to 255.255.255.0. • When the user downloads a program with netmask 0.0.0.0, the device displays 255.255.255.0 after download. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: Customized slide keys were not being updated by the replace system graphics option and during firmware updates. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Resolved: The touch area to bring out the F-Keys in the upper, right corner was too big which was interfering with touchscreen buttons in that area. | |
| Canvas 4, 5, 7, 7D, 10D | 17.06 | November 2024 | Bug Fix | Canvas 10D Only Resolved: Booting issue in which the ambient temperature was very hot (60C) / cold (-10C) for Canvas 10D. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | |
| Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | |
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. |
|
| Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | |
RCC SERIES
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| RCC Series | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| RCC Series | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| RCC Series | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| RCC Series | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| RCC Series | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| RCC Series | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| RCC Series | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| RCC Series | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| RCC Series | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||
| PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
|---|---|---|---|---|---|---|
| RCC Series | 15.76 | 2/4/26 | Enhancement | Security improvements Ethernet ports are open only if they are configured in Cscape and downloaded to the device. | Bootloader, Cscape 10.1 or later | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved Email sending using the cell modem was not working after restoring the signal, resulting in a send failure. | Bootloader | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved In the report configuration, if the first line was left empty and the “Form feed at End of Report” option was unchecked, the report printed only on the first trigger and failed to print on subsequent triggers. | Bootloader | |
| RCC Series | 15.76 | 2/4/26 | Bug Fix | Resolved The device displayed a System Exception when devices with dual ports were configured with Modbus TCP and had more than 512 total scan list entries across both ports. | Bootloader | |
| Download >Download Firmware 15.76 Release Notes | ||||||
| RCC Series | 15.74 | 7/25/25 | Bug Fix | • Resolved: After refreshing webpages, the Trend Data on webpages displayed the average of the actual data. • Resolved: Added support for the following Retentive Trend types: Average, Minimum, Maximum, and Downsample | Bootloader, Cscape 10.1 or later | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: Bitmaps were not being displayed on the device. | Bootloader | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: The device was not sending the NMT Start Command to CANOpen devices after power up. | Bootloader | |
| RCC Series | 15.74 | 7/25/25 | Bug Fix | Resolved: The email stopped working when using Secomea Email Relay on port 25 without authentication. | Bootloader | |
| Download >Download Firmware 15.74 Release Notes | ||||||
| RCC Series | 15.70 | 9/20/24 | Enhancement | Added support for OCSIO models ADC270 and DQM602. | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Enhancement | Retain variables support added for variable-based advanced ladder logic. Note: This requires Cscape version 10 onwards. | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Modbus Client sending Zero Value when Holding Register is Not Zero | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: CAN2 stopped working after several power cycles | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Screen calibration was being corrupted when data was being written beyond 128 words (%M2048) using Write Removable Media block | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: UTC time was not updating when downloaded from Cscape | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Title bar of password object was showing nonsense language when Unicode fonts were created | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: WebMI alarm history page not listing the RTN alarms | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: CV value of a PID block was not being updated when configured in the Enhanced IEC program | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was being updated in RM copy and delete blocks | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Gmail was not working for certain SMTP IPs | Bootloader, Cscape 9.90 SP10 | |
| RCC Series | 15.70 | 9/20/24 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in system menu | view status | Bootloader, Cscape 9.90 SP10 | |
| Download >Download Firmware 15.70 Release Notes | ||||||