Firmware Release Note Changelog
Download
Firmware Update Manual for Micro OCS & XL Series
Download
Firmware Update Manual for Prime Series
Controller Firmware Changelog
These manuals describe how to update or change firmware on the Horner OCS Controllers. Updating firmware to the newest version adds new benefits to the controller. Also, changing firmware is necessary when changing communications between CsCAN and CANopen, so the controller firmware changelog can help your products stay up to date.
Remember: Updating firmware will clear the application program, screens, configurations, and register data.
If required, make sure to backup program and register data before updating firmware. The controller’s User Manual has instructions for doing backups.
You can view and download all Release Notes below:
MICRO OCS SERIES
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
X2 | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
X2 | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
X2 | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
X2 | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein alarm history list was not getting retained after power cycle (5817) NOTE: Applicable to X2 only. | Bootloader | |
X2 | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
X2 | Download Firmware 15.62 Release Notes | |||||
X2 | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
X2 | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
X2 | CSCAN 15.56 | September 2021 | Bug Fix | Resolve issue when occasionally microSD card was not detecting / reading properly when card was plugged and unplugged repeatedly. (4703) | Bootloader | |
X2 | Download Firmware 15.56 Release Notes | |||||
X2 | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when Modbus communication on MJ2 stops working and unit locks up. (2769) | Bootloader | |
X2 | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when MJ1 RS 232 Handshake fails on XLEe Generation 2 (Data Set Ready / DSR) - issue related to Modem. (5171) | Bootloader | |
X2 | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue where in Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
X2 | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when using the Report Editor, an extra | Bootloader | |
X2 | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue wherein X2 was locking up which used Serial Modbus Master protocol. (5622) | Bootloader | |
X2 | Download Firmware 15.54 Release Notes | |||||
X2 | CSCAN 15.52 | May 2021 | Enhancement | Increased ladder size from 256KB to 512KB. (4318) | Bootloader | |
X2 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943) | Bootloader | |
X2 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646) | Bootloader | |
X2 | Download Firmware 15.52 Release Notes | |||||
X2 | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | Cscape 9.90 SP3 | |
X2 | CSCAN 15.40 | July 2020 | Enhancement | Email with TLS encryption support (Ethernet based units only) | Cscape 9.90 SP3 | |
X2 | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | Cscape 9.90 SP3 | |
X2 | CSCAN 15.40 | July 2020 | Enhancement | Load of firmware using MicroSD (Ethernet based units only) | ||
X2 | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
X2 | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
X2 | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
X2 | CSCAN 15.40 | July 2020 | Bug Fix | Reduced Jitter for analog inputs, making them more stable | ||
X2 | Download Firmware 15.40 Release Notes | |||||
X2A | CSCAN 15.24 | Sept 2019 | Bug Fix | During boot up, the analog outputs are ON at a level of approximately 20mA for up to two (2) seconds. The analog outputs return to their normal levels when boot up is complete. | REV BB or earlier* | |
X2R | CSCAN 15.24 | Sept 2019 | Bug Fix | During boot up, the analog outputs are ON at a level of approximately 20mA for up to two (2) seconds. The analog outputs return to their normal levels when boot up is complete. | REV BB or earlier* | |
X2 | Download Firmware 15.24 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
X4 | FW 15.82 | April 2024 | Enhancement | Resolved issue where System menu | View Status displays both Build version and Firmware version. | ||
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where unit locked up / froze when serial downloadable protocol was configured. This occurred randomly and was seen in limited hardware | ||
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where hardfault errors occur when CANopen SmartRail is configured in the program and downloaded | ||
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where endless loop of nameless folders were being created when "A:\" in Copy RM block was entered by the user. | ||
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where title bar of password object was showing mixed characters when unicode fonts were created. | ||
X4 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where WebMI alarm history page not listing the RTN alarms | ||
X4 | FW 15.82 | Download Firmware 15.82 Release Notes | ||||
X4 | CSCAN 15.78 | October 2023 | Enhancement | Added CNX100 support for Micro OCS Series. NOTE: Requires Cscape v. 9.90 SP10 onwards. | ||
X4 | CSCAN 15.78 | October 2023 | Enhancement | Added BACNet MSTP downloadable protocol support for Micro OCS Series. NOTE: Requires Cscape v. 9.90 SP11 onwards. | ||
X4 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved issue wherein device was displaying exception for a specific program which had Copy_CF block tagged with register greater than %R2048 in IEC languages. (7631) | ||
X4 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved issue where in unit displayed "User Program: Fault" or "APP CRC" error at bootup. (10795) | ||
X4 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved Cscape connectivity issue via ethernet communication when running EGD protocol. (10761) | ||
X4 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved X10 reset issue when multiple error messages were received by the controller for serial communication protocols. (10840) | ||
X4 | CSCAN 15.76 | July 2023 | Enhancement | OCSIO support has been added along with new modules - DIM610 and DQM606. NOTE: New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | ||
X4 | CSCAN 15.76 | July 2023 | Enhancement | Increased PID blocks support from 4 to 8 for Micro OCS series. NOTE: Requires Cscape 9.90 SP9 onwards. | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved erasing of analog calibration information after updating to FW 15.70 (10418) NOTE: Addressed issue related to both upgrade and downgrade of firmware. | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved touch calibration issue after loading FW 15.70 (10553) NOTE: The cross hair at the upper left of the screen does not work in Touch Calibration | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when timer output was turning on at startup. (7639 / 1390) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when after power cycle, the first pulse output duration was either missed or too short. (7634) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when Filename Counter was not working properly if a file with screen capture was downloaded previously. (5717) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when unit would lose communication with Cscape over Ethernet when there were multiple slaves configured in the program but not connected. (4700) NOTE: Occurrence of issue has been reduced | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when WebMI license was lost if there was a flat or faulty controller battery. License duration check will not be done for lifetime licenses, so even if battery fails, license will be valid for lifetime licenses. (3429) NOTE: For permanent license, check for RTC time has been removed | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when screen response to Momentary Button was not working properly for a large button configured on the screen. (8439) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when screen saver was not working for a few hardware revisions. (8018) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when frequent timeouts and reconnects were seen on units running EtherNet/IP server. (8541) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue with Modbus TCP communication when 6 or more devices were used. (8362) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when combining characters like Thai fonts were not displayed properly in the Graphics Editor. (3878) NOTE: Requires Cscape 9.90 SP9 onwards. | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464 / 7052 / 7508) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved flash erase issue on a few hardware revisions after loading 15.60 firmware. (9197) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when user access alarms webpage via web designer model device displayed HardFault error. (8288) NOTE: Issue was seen when unicode strings were configured in alarms configuration. | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when device displayed HardFault error when Modbus TCP/IP device list configured with more than 32 slaves was downloaded to device. (7495 / 8531) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when emails sent from the OCS were being treated as spam emails due to email header missing time zone. (9105) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when Quadrature HSC output was not working. (6468) | ||
X4 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when accessing webpages used to display frequent "connection timeout". (9869 / 7583) | ||
X4 | CSCAN 15.76 | Download Firmware 15.76 Release Notes | ||||
X4 | CSCAN 15.60 | December 2022 | Bug Fix | Resolved input glitch caused by beeper function. | Bootloader | |
X4 | CSCAN 15.60 | Download Firmware 15.58 Release Notes | ||||
X4 | CSCAN 15.58 | December 2021 | Enhancement | Added support for alternative hardware components. | Bootloader | |
X4 | Download Firmware 15.58 Release Notes | |||||
X4 | CSCAN 15.54 | August 2021 | Enhancement | WebMI status bits have been added for Session Count: %SR101.5 to SR101.7 | Bootloader | |
X4 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: When using the Report Editor, an extra space or multiple spaces was being added to the end of the report before the Carriage Return.. (4699) | Bootloader | |
X4 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
X4 | CSCAN 15.54 | August 2021 | Bug Fix | Made touch calibration faster. (1420) | Bootloader | |
X4 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: ModbusTCP communication was not starting until Reacquire Time has timed out during power up or sometimes when unit is put from Idle to Run mode. (5042) | Bootloader | |
X4 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: sometimes microSD card was not detecting / reading properly when plugged and unplugged continuously. (4703) | Bootloader | |
X4 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved WebMI Issue: Previous session(s) was not getting closed which resulted in connection timeout during long run as max sessions were reached. (4980) | Bootloader | |
X4 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: MJ1 RS 232 hardware Handshake fails (DSR / DTR) - issue related to Modem. (5171) | Bootloader | |
X4 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issues: (5398) Modbus TCP. When Update Interval was utilized (set other than zero), if packets were delayed beyond the set Update Interval time, previous sockets were getting closed before the re-connect packet was sent. And therefore comms would not recover automatically. The issue would typically be seen when the Update Interval was set to time periods that exceed the server timeout time. | Bootloader | |
X4 | Download Firmware 15.54 Release Notes | |||||
X4 | CSCAN 15.52 | May 2021 | Enhancement | Increased ladder size from 256KB to 512KB. (4318) | Bootloader | |
X4 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Email with TLS encryption (Gmail) was not working with the ethernet downloadable protocol. (3711) | Bootloader | |
X4 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943) | Bootloader | |
X4 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646) | Bootloader | |
X4 | Download Firmware 15.52 Release Notes | |||||
X4 | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | Cscape 9.90 SP3 | |
X4 | CSCAN 15.40 | July 2020 | Enhancement | Email with TLS encryption support (Ethernet based units only) | Cscape 9.90 SP3 | |
X4 | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | Cscape 9.90 SP3 | |
X4 | CSCAN 15.40 | July 2020 | Enhancement | Increase in objects to 100 per screen | Cscape 9.90 SP3 | |
X4 | CSCAN 15.40 | July 2020 | Enhancement | HSQ Output with pulse width selection | Cscape 9.90 SP3 | |
X4 | CSCAN 15.40 | July 2020 | Enhancement | Load of firmware using MicroSD | ||
X4 | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
X4 | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
X4 | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
X4 | CSCAN 15.40 | July 2020 | Bug Fix | Reduced Jitter for analog inputs, making them more stable | ||
X4 | Download Firmware 15.40 Release Notes | |||||
X4A | CSCAN 15.28 | April 2020 | Bug Fix | Pressing objects on the touchscreen in continuous, rapid succession with the beeper enabled (System Menu → Set Beeper) could cause an undesired switching of digital inputs. This issue does not occur if the internal beeper is turned off. | REV BB or earlier* | |
X4R | CSCAN 15.28 | April 2020 | Bug Fix | Pressing objects on the touchscreen in continuous, rapid succession with the beeper enabled (System Menu → Set Beeper) could cause an undesired switching of digital inputs. This issue does not occur if the internal beeper is turned off. | REV BB or earlier* | |
X4 | Download Firmware 15.28 Release Notes | |||||
X4A | CSCAN 15.18 | January 2019 | Bug Fix | Reduce unnecessary current draw (without power) on the Backup Battery. | Rev AA only | |
X4 | Download PUN Notes for Power Loss Details | |||||
X4 | Download Firmware 15.18 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
X5 | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
X5 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
X5 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
X5 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
X5 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
X5 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
X5 | 15.62 | 5/8/23 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
X5 | 15.62 | 5/8/23 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
X5 | 15.62 | 5/8/23 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
Download >Download Firmware 15.62 Release Notes | ||||||
X5 | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
X5 | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
X5 | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
X5 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
X5 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
X5 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
X5 | Download Firmware 15.60 Release Notes | |||||
X5 | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | F-keys tied to switch screen coils would sometimes remain held during the screen switch until pressed again. (4668) NOTE: Applies to EXL6, EXLW and X5 only. | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
X5 | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
X5 | Download Firmware 15.54 Release Notes | |||||
X5 | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting | Bootloader, Cscape 9.90 SP4 | |
X5 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
X5 | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Licensed Enhancement | J1939 - J1939 protocol may now be licensed and added in the field for all XL4, EXL6, EXLW and X5 products. | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | X5 only - Resolved a System Exception fault while accessing WebMI and while microSD was unplugged – immediately after a program download (4551). | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | X5 only - Corrected an analog accuracy issue introduced in firmware 15.42 after re-calibration of analog channels. Updating to 15.52 corrects the analog accuracy issue with no re-calibration required (4723). | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
X5 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
X5 | Download Firmware 15.52 Release Notes | |||||
X5 | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | Cscape 9.90 SP3 | |
X5 | CSCAN 15.40 | July 2020 | Enhancement | DHCP and DNS Support | ||
X5 | CSCAN 15.40 | July 2020 | Enhancement | MQTT - Sparkplug (licensed feature) | ||
X5 | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | ||
X5 | CSCAN 15.40 | July 2020 | Enhancement | Added X5 Factory Calibration | ||
X5 | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
X5 | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
X5 | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
X5 | CSCAN 15.40 | July 2020 | Bug Fix | IP default HE-WIFIUSB | ||
X5 | CSCAN 15.40 | July 2020 | Bug Fix | Local Date (Day) rolls back at month change | ||
X5 | Download Firmware 15.40 Release Notes | |||||
X5 | CSCAN 15.30 | October 2019 | Enhancement | BACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process. | ||
X5 | CSCAN 15.30 | October 2019 | Enhancement | Basic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410. | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | Possible reset when copying large files from uSD to USB | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | Error using wildcards in Removable Media blocks | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed issue where format size of microSD was limited to 1GB | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | Alarms not displayed on web pages in WebMI | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | System exception for some programs due to issue with incorrect value for baud rate for J1939 | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed an issue that prevented login after download | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | Date format changed to DD-Mon-YY in retentive trend playback | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | Alarm object display did not show live refresh for WebMI | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | Off Delay Timer output was energizing when no power was applied to Timer in first scan | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | HE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration | ||
X5 | CSCAN 15.30 | October 2019 | Bug Fix | When the password data object is set for user access object type, the visibility does not work as expected. | ||
X5 | Download Firmware 15.30 Release Notes | |||||
X5 | CSCAN 15.20 | April 2019 | Enhancement | Improved provisions for automatic and manual text wrapping for buttons. | Cscape 9.90 | |
X5 | CSCAN 15.20 | April 2019 | Enhancement | The Needle-only gauge (previously Classic-style) now supports Triangle and Rhombus needle styles as in the advanced gauge style. | Cscape 9.90 | |
X5 | CSCAN 15.20 | April 2019 | Enhancement | Added support for the Video object for the X5 Controller. | Cscape 9.90 | |
X5 | CSCAN 15.20 | April 2019 | Enhancement | Added Digital filtering for the High-speed counting function of several controllers. | Cscape 9.90 | |
X5 | CSCAN 15.20 | April 2019 | Enhancement | Added Set CAN ID function block in Advanced Ladder editor. | Cscape 9.90 | |
X5 | CSCAN 15.20 | April 2019 | Enhancement | Improved Indirect Move function block for more flexible use with Tag-based ladder programming. | Cscape 9.90 | |
X5 | CSCAN 15.20 | April 2019 | Enhancement | Added support for multiple baud rates (250K, 500K, 1M) for J1939 Protocol. | Cscape 9.90 | |
X5 | CSCAN 15.20 | April 2019 | Enhancement | Improved Boot-up Time | Cscape 9.90 | |
X5 | CSCAN 15.20 | April 2019 | Bug Fix | Corrected issue that broke ethernet communications with certain EGD (Ethernet Global Data) configurations. | ||
X5 | CSCAN 15.20 | April 2019 | Bug Fix | Improved Analog Input jitter on X5 controllers | ||
X5 | CSCAN 15.20 | April 2019 | Bug Fix | The Email status was corrected. NOTE: See Cscape 9.90 Help file for updated information. | ||
X5 | CSCAN 15.20 | April 2019 | Bug Fix | Corrected an issue with email file attachments where the first letter of the attached file name was cut off. | ||
X5 | CSCAN 15.20 | April 2019 | Bug Fix | Improved EXL10 Backlight dimming. In some cases, dimming to 50% previously caused flickering. | ||
X5 | CSCAN 15.20 | April 2019 | Bug Fix | Multiple improvements to rechargeable battery handling.* | ||
X5 | CSCAN 15.20 | April 2019 | Bug Fix | Corrected issues where FTP was not working in certain circumstances. | ||
Download PUN Notes for Power Loss Details | ||||||
Download Firmware 15.20 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
X7 | FW 15.82 | April 2024 | Enhancement | Resolved issue where System menu | View Status displays both Build version and Firmware version. | ||
X7 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where unit locked up / froze when serial downloadable protocol was configured. This occurred randomly and was seen in limited hardware | ||
X7 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where hardfault errors occur when CANopen SmartRail is configured in the program and downloaded | ||
X7 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where endless loop of nameless folders were being created when "A:\" in Copy RM block was entered by the user. | ||
X7 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where title bar of password object was showing mixed characters when unicode fonts were created. | ||
X7 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where WebMI alarm history page not listing the RTN alarms | ||
X7 | FW 15.82 | Download Firmware 15.82 Release Notes | ||||
X7 | CSCAN 15.78 | October 2023 | Enhancement | Added CNX100 support for Micro OCS Series. NOTE: Requires Cscape v. 9.90 SP10 onwards. | ||
X7 | CSCAN 15.78 | October 2023 | Enhancement | Added BACNet MSTP downloadable protocol support for Micro OCS Series. NOTE: Requires Cscape v. 9.90 SP11 onwards. | ||
X7 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved issue wherein device was displaying exception for a specific program which had Copy_CF block tagged with register greater than %R2048 in IEC languages. (7631) | ||
X7 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved issue where in unit displayed "User Program: Fault" or "APP CRC" error at bootup. (10795) | ||
X7 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved Cscape connectivity issue via ethernet communication when running EGD protocol. (10761) | ||
X7 | CSCAN 15.78 | October 2023 | Bug Fix | Resolved X10 reset issue when multiple error messages were received by the controller for serial communication protocols. (10840) | ||
X7 | CSCAN 15.76 | July 2023 | Enhancement | OCSIO support has been added along with new modules - DIM610 and DQM606. NOTE: New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | ||
X7 | CSCAN 15.76 | July 2023 | Enhancement | Increased PID blocks support from 4 to 8 for Micro OCS series. NOTE: Requires Cscape 9.90 SP9 onwards. | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved erasing of analog calibration information after updating to FW 15.70 (10418) NOTE: Addressed issue related to both upgrade and downgrade of firmware. | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved touch calibration issue after loading FW 15.70 (10553) NOTE: The cross hair at the upper left of the screen does not work in Touch Calibration | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when timer output was turning on at startup. (7639 / 1390) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when after power cycle, the first pulse output duration was either missed or too short. (7634) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when Filename Counter was not working properly if a file with screen capture was downloaded previously. (5717) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when unit would lose communication with Cscape over Ethernet when there were multiple slaves configured in the program but not connected. (4700) NOTE: Occurrence of issue has been reduced | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when WebMI license was lost if there was a flat or faulty controller battery. License duration check will not be done for lifetime licenses, so even if battery fails, license will be valid for lifetime licenses. (3429) NOTE: For permanent license, check for RTC time has been removed | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when screen response to Momentary Button was not working properly for a large button configured on the screen. (8439) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when screen saver was not working for a few hardware revisions. (8018) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when frequent timeouts and reconnects were seen on units running EtherNet/IP server. (8541) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue with Modbus TCP communication when 6 or more devices were used. (8362) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when combining characters like Thai fonts were not displayed properly in the Graphics Editor. (3878) NOTE: Requires Cscape 9.90 SP9 onwards. | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464 / 7052 / 7508) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved flash erase issue on a few hardware revisions after loading 15.60 firmware. (9197) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when user access alarms webpage via web designer model device displayed HardFault error. (8288) NOTE: Issue was seen when unicode strings were configured in alarms configuration. | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when device displayed HardFault error when Modbus TCP/IP device list configured with more than 32 slaves was downloaded to device. (7495 / 8531) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when emails sent from the OCS were being treated as spam emails due to email header missing time zone. (9105) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when Quadrature HSC output was not working. (6468) | ||
X7 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when accessing webpages used to display frequent "connection timeout". (9869 / 7583) | ||
X7 | CSCAN 15.76 | Download Firmware 15.76 Release Notes | ||||
X7 | CSCAN 15.60 | December 2022 | Bug Fix | Resolved input glitch caused by beeper function. | Bootloader | |
X7 | Download Firmware 15.58 Release Notes | |||||
X7 | CSCAN 15.58 | December 2021 | Enhancement | Added support for alternative hardware components. | Bootloader | |
X7 | Download Firmware 15.58 Release Notes | |||||
X7 | CSCAN 15.54 | August 2021 | Enhancement | WebMI status bits have been added for Session Count: %SR101.5 to SR101.7 | Bootloader | |
X7 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: When using the Report Editor, an extra space or multiple spaces was being added to the end of the report before the Carriage Return.. (4699) | Bootloader | |
X7 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
X7 | CSCAN 15.54 | August 2021 | Bug Fix | Made touch calibration faster. (1420) | Bootloader | |
X7 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: ModbusTCP communication was not starting until Reacquire Time has timed out during power up or sometimes when unit is put from Idle to Run mode. (5042) | Bootloader | |
X7 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: sometimes microSD card was not detecting / reading properly when plugged and unplugged continuously. (4703) | Bootloader | |
X7 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved WebMI Issue: Previous session(s) was not getting closed which resulted in connection timeout during long run as max sessions were reached. (4980) | Bootloader | |
X7 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: MJ1 RS 232 hardware Handshake fails (DSR / DTR) - issue related to Modem. (5171) | Bootloader | |
X7 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issues: (5398) Modbus TCP. When Update Interval was utilized (set other than zero), if packets were delayed beyond the set Update Interval time, previous sockets were getting closed before the re-connect packet was sent. And therefore comms would not recover automatically. The issue would typically be seen when the Update Interval was set to time periods that exceed the server timeout time. | Bootloader | |
X7 | Download Firmware 15.54 Release Notes | |||||
X7 | CSCAN 15.52 | May 2021 | Enhancement | Increased ladder size from 256KB to 512KB. (4318) | Bootloader | |
X7 | CSCAN 15.52 | May 2021 | Bug Fix | X7 & X10 only - Resolved issue where slider buttons were too small. (4318) | Bootloader | |
X7 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Email with TLS encryption (Gmail) was not working with the ethernet downloadable protocol. (3711) | Bootloader | |
X7 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943) | Bootloader | |
X7 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646) | Bootloader | |
X7 | Download Firmware 15.52 Release Notes | |||||
X7 | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | Cscape 9.90 SP3 | |
X7 | CSCAN 15.40 | July 2020 | Enhancement | Email with TLS encryption support (Ethernet based units only) | Cscape 9.90 SP3 | |
X7 | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | Cscape 9.90 SP3 | |
X7 | CSCAN 15.40 | July 2020 | Enhancement | Increase in objects to 100 per screen | Cscape 9.90 SP3 | |
X7 | CSCAN 15.40 | July 2020 | Enhancement | HSQ Output with pulse width selection | Cscape 9.90 SP3 | |
X7 | CSCAN 15.40 | July 2020 | Enhancement | Load of firmware using MicroSD | ||
X7 | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
X7 | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
X7 | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
X7 | CSCAN 15.40 | July 2020 | Bug Fix | Reduced Jitter for analog inputs, making them more stable | ||
X7 | Download Firmware 15.40 Release Notes | |||||
X7A | CSCAN 15.24 | April 2020 | Bug Fix | During boot up, the analog outputs are ON at a level of approximately 20mA for up to two (2) seconds. The analog outputs return to their normal levels when boot up is complete. | REV AA (first revision)* | |
X7R | CSCAN 15.24 | April 2020 | Bug Fix | During boot up, the analog outputs are ON at a level of approximately 20mA for up to two (2) seconds. The analog outputs return to their normal levels when boot up is complete. | REV AA (first revision)* | |
X7 | *NOTE: Controller Revision Level – Horner controllers have a two-letter revision level. The first letter of the revision is the HARDWARE REVISION, and the second letter of the revision is the FIRMWARE REVISION. | |||||
X7 | Download Firmware 15.24 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
X10 | FW 15.82 | April 2024 | Enhancement | Resolved issue where System menu | View Status displays both Build version and Firmware version. | ||
X10 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where unit locked up / froze when serial downloadable protocol was configured. This occurred randomly and was seen in limited hardware | ||
X10 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where hardfault errors occur when CANopen SmartRail is configured in the program and downloaded | ||
X10 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where endless loop of nameless folders were being created when "A:\" in Copy RM block was entered by the user. | ||
X10 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where title bar of password object was showing mixed characters when unicode fonts were created. | ||
X10 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where WebMI alarm history page not listing the RTN alarms | ||
X10 | FW 15.82 | April 2024 | Bug Fix | Resolved issue where touching one place on the screen registers touch on other parts of the screen. Only seen in some but not all, X10 hardware(s). | ||
X10 | CSCAN 15.76 | July 2023 | Enhancement | OCSIO support has been added along with new modules - DIM610 and DQM606. NOTE: New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | ||
X10 | CSCAN 15.76 | July 2023 | Enhancement | Increased PID blocks support from 4 to 8 for Micro OCS series. NOTE: Requires Cscape 9.90 SP9 onwards. | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved erasing of analog calibration information after updating to FW 15.70 (10418) NOTE: Addressed issue related to both upgrade and downgrade of firmware. | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved touch calibration issue after loading FW 15.70 (10553) NOTE: The cross hair at the upper left of the screen does not work in Touch Calibration | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when timer output was turning on at startup. (7639 / 1390) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when after power cycle, the first pulse output duration was either missed or too short. (7634) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when Filename Counter was not working properly if a file with screen capture was downloaded previously. (5717) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when unit would lose communication with Cscape over Ethernet when there were multiple slaves configured in the program but not connected. (4700) NOTE: Occurrence of issue has been reduced | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when WebMI license was lost if there was a flat or faulty controller battery. License duration check will not be done for lifetime licenses, so even if battery fails, license will be valid for lifetime licenses. (3429) NOTE: For permanent license, check for RTC time has been removed | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when screen response to Momentary Button was not working properly for a large button configured on the screen. (8439) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when screen saver was not working for a few hardware revisions. (8018) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when frequent timeouts and reconnects were seen on units running EtherNet/IP server. (8541) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue with Modbus TCP communication when 6 or more devices were used. (8362) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when combining characters like Thai fonts were not displayed properly in the Graphics Editor. (3878) NOTE: Requires Cscape 9.90 SP9 onwards. | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464 / 7052 / 7508) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved flash erase issue on a few hardware revisions after loading 15.60 firmware. (9197) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when user access alarms webpage via web designer model device displayed HardFault error. (8288) NOTE: Issue was seen when unicode strings were configured in alarms configuration. | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when device displayed HardFault error when Modbus TCP/IP device list configured with more than 32 slaves was downloaded to device. (7495 / 8531) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when emails sent from the OCS were being treated as spam emails due to email header missing time zone. (9105) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when Quadrature HSC output was not working. (6468) | ||
X10 | CSCAN 15.76 | July 2023 | Bug Fix | Resolved issue when accessing webpages used to display frequent "connection timeout". (9869 / 7583) | ||
X10 | CSCAN 15.76 | Download Firmware 15.76 Release Notes | ||||
X10 | CSCAN 15.60 | December 2022 | Bug Fix | Resolved input glitch caused by beeper function. | Bootloader | |
X10 | Download Firmware 15.58 Release Notes | |||||
X10 | CSCAN 15.58 | December 2021 | Enhancement | Added support for alternative hardware components. | Bootloader | |
X10 | Download Firmware 15.58 Release Notes | |||||
X10 | CSCAN 15.54 | August 2021 | Enhancement | WebMI status bits have been added for Session Count: %SR101.5 to SR101.7 | Bootloader | |
X10 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: When using the Report Editor, an extra space or multiple spaces was being added to the end of the report before the Carriage Return.. (4699) | Bootloader | |
X10 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
X10 | CSCAN 15.54 | August 2021 | Bug Fix | Made touch calibration faster. (1420) | Bootloader | |
X10 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: ModbusTCP communication was not starting until Reacquire Time has timed out during power up or sometimes when unit is put from Idle to Run mode. (5042) | Bootloader | |
X10 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: sometimes microSD card was not detecting / reading properly when plugged and unplugged continuously. (4703) | Bootloader | |
X10 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved WebMI Issue: Previous session(s) was not getting closed which resulted in connection timeout during long run as max sessions were reached. (4980) | Bootloader | |
X10 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issue: MJ1 RS 232 hardware Handshake fails (DSR / DTR) - issue related to Modem. (5171) | Bootloader | |
X10 | CSCAN 15.54 | August 2021 | Bug Fix | Resolved Issues: (5398) Modbus TCP. When Update Interval was utilized (set other than zero), if packets were delayed beyond the set Update Interval time, previous sockets were getting closed before the re-connect packet was sent. And therefore comms would not recover automatically. The issue would typically be seen when the Update Interval was set to time periods that exceed the server timeout time. | Bootloader | |
X10 | Download Firmware 15.54 Release Notes | |||||
X10 | CSCAN 15.52 | May 2021 | Enhancement | Increased ladder size from 256KB to 512KB. (4318) | Bootloader | |
X10 | CSCAN 15.52 | May 2021 | Enhancement | X10 only - Increased bmp size from 4MB to 6MB | Bootloader | |
X10 | CSCAN 15.52 | May 2021 | Enhancement | X10 only - Reduced Auto calibration time | Bootloader | |
X10 | CSCAN 15.52 | May 2021 | Bug Fix | X7 & X10 only - Resolved issue where slider buttons were too small. (4318) | Bootloader | |
X10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Email with TLS encryption (Gmail) was not working with the ethernet downloadable protocol. (3711) | Bootloader | |
X10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943) | Bootloader | |
X10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646) | Bootloader | |
X10 | Download Firmware 15.52 Release Notes |
XL SERIES
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XLE/XLEe | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe only | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe only | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | Download Firmware 15.62 Release Notes | |||||
XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
XLEe only | CSCAN 15.58 | March 2022 | New Feature | Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or | Bootloader | |
XLEe only | microSD card was removed. (9554/1258) | |||||
XLE/XLEe | CSCAN 15.56 | September 2021 | Enhancement | WebMI status bits have been added for session Count - %SR101.5 to SR101.7. (4980) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolve issue when occasionally microSD card was not detecting / reading properly when card was plugged and unplugged repeatedly. (4703) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved the following issues (5398) - a. Packets were getting delayed beyond the set update interval when the update interval option was selected in the Client Protocol b. Previous sockets were getting closed before sending the reconnect packet | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved WebMI issue that if previous sessions were not getting closed, then a connection timeout occurred during long run as max sessions were reached. (4980) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved issue when ModbusTCP communication was not starting until Reacquire Time had timed out during power up or occasionally when unit was moved from Idle to Run mode. (5042) | Bootloader | |
XLE/XLEe | Download Firmware 15.56 Release Notes | |||||
XLE/XLEe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when Modbus communication on MJ2 stops working and unit locks up. (2769) | Bootloader | |
XLEe only | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when MJ1 RS 232 Handshake fails on XLEe Generation 2 (Data Set Ready / DSR) - issue related to Modem. (5171) | Bootloader | |
XLE/XLEe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue where in Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
XLE/XLEe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when using the Report Editor, an extra | Bootloader | |
XLE/XLEe | Download Firmware 15.54 Release Notes | |||||
XLE/XLEe | CSCAN 15.52 | May 2021 | Enhancement | Increased ladder size from 256KB to 512KB. (4318) | Bootloader | |
XLE/XLEe | CSCAN 15.52 | May 2021 | Bug Fix | XLE/XLEe and XLT/XLTe only - Resolved issue where stepper count was off by 1 or 2 in second generation XLE. (4004) | Bootloader | |
XLEe only | CSCAN 15.52 | May 2021 | Bug Fix | XLEe and XLTe only - Resolved issue where email was not working if Modbus TCP was configured. (3711) | Bootloader | |
XLE/XLEe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943) | Bootloader | |
XLE/XLEe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646) | Bootloader | |
XLE/XLEe | Download Firmware 15.52 Release Notes | |||||
XLE/XLEe | CSCAN 15.44 | January 2021 | Bug Fix | In rare cases, analog inputs of Model 5 I/O will not update at power up or can stop updating during operation. | Hardware rev TU and later | |
XLE/XLEe | CSCAN 15.44 | January 2021 | Bug Fix | Using the stepper count function will result in extra pulses beyond the setpoint. | Hardware rev TU and later | |
XLE/XLEe | CSCAN 15.44 | *NOTE: If upgrading from Firmware 15.40, a power cycle is required when the firmware upgrade is complete. | ||||
XLE/XLEe | Download Firmware 15.44 Release Notes | |||||
XLE/XLEe | CSCAN 15.24 | January 2020 | Bug Fix | Could not load 15.20 Firmware and new CPLD on new blank XLE units. | ||
XLE/XLEe | CSCAN 15.24 | January 2020 | * NOTE: Does not affect post-production units that are flashed with earlier versions | |||
XLE/XLEe | Download Firmware 15.24 Release Notes | |||||
XLE only | CSCAN 15.18 | January 2019 | Bug Fix | Reduce unnecessary current draw (without power) on the Backup Battery. | Rev TA-VD | |
XLE only | Download PUN Notes for Power Loss Details | |||||
XLE only | Download Firmware 15.18 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XLE/XLEe | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe only | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe only | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLE/XLEe | Download Firmware 15.62 Release Notes | |||||
XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
XLE/XLEe | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
XLEe only | CSCAN 15.58 | March 2022 | New Feature | Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or | Bootloader | |
XLEe only | microSD card was removed. (9554/1258) | |||||
XLE/XLEe | CSCAN 15.56 | September 2021 | Enhancement | WebMI status bits have been added for session Count - %SR101.5 to SR101.7. (4980) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolve issue when occasionally microSD card was not detecting / reading properly when card was plugged and unplugged repeatedly. (4703) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved the following issues (5398) - a. Packets were getting delayed beyond the set update interval when the update interval option was selected in the Client Protocol b. Previous sockets were getting closed before sending the reconnect packet | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved WebMI issue that if previous sessions were not getting closed, then a connection timeout occurred during long run as max sessions were reached. (4980) | Bootloader | |
XLE/XLEe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved issue when ModbusTCP communication was not starting until Reacquire Time had timed out during power up or occasionally when unit was moved from Idle to Run mode. (5042) | Bootloader | |
XLE/XLEe | Download Firmware 15.56 Release Notes | |||||
XLE/XLEe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when Modbus communication on MJ2 stops working and unit locks up. (2769) | Bootloader | |
XLEe only | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when MJ1 RS 232 Handshake fails on XLEe Generation 2 (Data Set Ready / DSR) - issue related to Modem. (5171) | Bootloader | |
XLE/XLEe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue where in Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
XLE/XLEe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when using the Report Editor, an extra | Bootloader | |
XLE/XLEe | Download Firmware 15.54 Release Notes | |||||
XLE/XLEe | CSCAN 15.52 | May 2021 | Enhancement | Increased ladder size from 256KB to 512KB. (4318) | Bootloader | |
XLE/XLEe | CSCAN 15.52 | May 2021 | Bug Fix | XLE/XLEe and XLT/XLTe only - Resolved issue where stepper count was off by 1 or 2 in second generation XLE. (4004) | Bootloader | |
XLEe only | CSCAN 15.52 | May 2021 | Bug Fix | XLEe and XLTe only - Resolved issue where email was not working if Modbus TCP was configured. (3711) | Bootloader | |
XLE/XLEe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943) | Bootloader | |
XLE/XLEe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646) | Bootloader | |
XLE/XLEe | Download Firmware 15.52 Release Notes | |||||
XLE/XLEe | CSCAN 15.44 | January 2021 | Bug Fix | In rare cases, analog inputs of Model 5 I/O will not update at power up or can stop updating during operation. | Hardware rev TU and later | |
XLE/XLEe | CSCAN 15.44 | January 2021 | Bug Fix | Using the stepper count function will result in extra pulses beyond the setpoint. | Hardware rev TU and later | |
XLE/XLEe | CSCAN 15.44 | *NOTE: If upgrading from Firmware 15.40, a power cycle is required when the firmware upgrade is complete. | ||||
XLE/XLEe | Download Firmware 15.44 Release Notes | |||||
XLE/XLEe | CSCAN 15.24 | January 2020 | Bug Fix | Could not load 15.20 Firmware and new CPLD on new blank XLE units. | ||
XLE/XLEe | CSCAN 15.24 | January 2020 | * NOTE: Does not affect post-production units that are flashed with earlier versions | |||
XLE/XLEe | Download Firmware 15.24 Release Notes | |||||
XLE only | CSCAN 15.18 | January 2019 | Bug Fix | Reduce unnecessary current draw (without power) on the Backup Battery. | Rev TA-VD | |
XLE only | Download PUN Notes for Power Loss Details | |||||
XLE only | Download Firmware 15.18 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the resetting of controllers after clear application at higher temperatures. | Bootloader | |
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the issue in which endless loop of nameless folders were being created when user used "A:\" in Copy RM block. | Bootloader | |
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the issue in which combining characters such as Thai fonts were not displayed correctly. | Bootloader | |
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the issue in which the title bar of password object was showing mixed characters when Unicode fonts were created. | Bootloader | |
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved issue with loading of Clone files generated from Firmware version 14.xx or 15.xx to firmware 17.06. | Bootloader | |
XLTe only | CSCAN 17.06 | April 2024 | Bug Fix | Resolved Cscape connectivity issue via ethernet communication when running EGD protocol. | Bootloader | |
XLTe only | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the WebMI alarm history page due to not listing the RTN alarms. | Bootloader | |
XLT/XLTe | Download Firmware 17.06 Release Notes | |||||
XLT/XLTe | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe only | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe only | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | Download Firmware 15.62 Release Notes | |||||
XLT/XLTe | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
XLT/XLTe | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
XLTe only | CSCAN 15.58 | March 2022 | New Feature | Added support for alternative hardware components. | Bootloader | |
XLTe only | Download Firmware 15.58 Release Notes | |||||
XLT/XLTe | CSCAN 15.56 | September 2021 | Enhancement | WebMI status bits have been added for session Count - %SR101.5 to SR101.7. (4980) | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Bug Fix | Resolve issue when occasionally microSD card was not detecting / reading properly when card was plugged and unplugged repeatedly. (4703) | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved the following issues (5398) - a. Packets were getting delayed beyond the set update interval when the update interval option was selected in the Client Protocol b. Previous sockets were getting closed before sending the reconnect packet | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved WebMI issue that if previous sessions were not getting closed, then a connection timeout occurred during long run as max sessions were reached. (4980) | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved issue when ModbusTCP communication was not starting until Reacquire Time had timed out during power up or occasionally when unit was moved from Idle to Run mode. (5042) | Bootloader | |
XLT/XLTe | Download Firmware 15.56 Release Notes | |||||
XLT/XLTe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when Modbus communication on MJ2 stops working and unit locks up. (2769) | Bootloader | |
XLT/XLTe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue where in Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
XLT/XLTe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when using the Report Editor, an extra | Bootloader | |
XLT/XLTe | Download Firmware 15.54 Release Notes | |||||
XLT/XLTe | CSCAN 15.52 | May 2021 | Enhancement | Increased ladder size from 256KB to 512KB. (4318) | Bootloader | |
XLT/XLTe | CSCAN 15.52 | May 2021 | Bug Fix | XLE/XLEe and XLT/XLTe only - Resolved issue where stepper count was off by 1 or 2 in second generation XLE. (4004) | Bootloader | |
XLTe only | CSCAN 15.52 | May 2021 | Bug Fix | XLEe and XLTe only - Resolved issue where email was not working if Modbus TCP was configured. (3711) | Bootloader | |
XLT/XLTe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943) | Bootloader | |
XLT/XLTe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646) | Bootloader | |
XLT/XLTe | Download Firmware 15.52 Release Notes | |||||
XLT/XLTe | CSCAN 15.44 | January 2021 | Bug Fix | In rare cases, analog inputs of Model 5 I/O will not update at power up or can stop updating during operation. | Hardware rev TU and later | |
XLT/XLTe | CSCAN 15.44 | January 2021 | Bug Fix | Using the stepper count function will result in extra pulses beyond the setpoint. | Hardware rev TU and later | |
XLT/XLTe | CSCAN 15.44 | *NOTE: If upgrading from Firmware 15.40, a power cycle is required when the firmware upgrade is complete. | ||||
XLT/XLTe | Download Firmware 15.44 Release Notes | |||||
XLT/XLTe | CSCAN 15.24 | January 2020 | Bug Fix | Could not load 15.20 Firmware and new CPLD on new blank XLE units. | ||
XLT/XLTe | CSCAN 15.24 | January 2020 | * NOTE: Does not affect post-production units that are flashed with earlier versions | |||
XLT/XLTe | Download Firmware 15.24 Release Notes | |||||
XLT/XLTe | CSCAN 15.22 | October 2019 | Bug Fix | Added commands to the display update block for recovering from split screen. | ||
XLT/XLTe | Download Firmware 15.24 Release Notes | |||||
XLT only | CSCAN 15.18 | January 2019 | Bug Fix | Reduce unnecessary current draw (without power) on the Backup Battery. | Rev TA-UD | |
XLT only | Download PUN Notes for Power Loss Details | |||||
XLT only | Download Firmware 15.18 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the resetting of controllers after clear application at higher temperatures. | Bootloader | |
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the issue in which endless loop of nameless folders were being created when user used "A:\" in Copy RM block. | Bootloader | |
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the issue in which combining characters such as Thai fonts were not displayed correctly. | Bootloader | |
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the issue in which the title bar of password object was showing mixed characters when Unicode fonts were created. | Bootloader | |
XLT/XLTe | CSCAN 17.06 | April 2024 | Bug Fix | Resolved issue with loading of Clone files generated from Firmware version 14.xx or 15.xx to firmware 17.06. | Bootloader | |
XLTe only | CSCAN 17.06 | April 2024 | Bug Fix | Resolved Cscape connectivity issue via ethernet communication when running EGD protocol. | Bootloader | |
XLTe only | CSCAN 17.06 | April 2024 | Bug Fix | Resolved the WebMI alarm history page due to not listing the RTN alarms. | Bootloader | |
XLT/XLTe | Download Firmware 17.06 Release Notes | |||||
XLT/XLTe | CSCAN 15.62 | August 2023 | Enhancement | Added OCS-I/O support for all models. NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup (7639) | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein after power cycle the first pulse output duration was either missed or way too short (7634) | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein unit would lose communication with Cscape over Ethernet when there are multiple slaves configured in the program but not connected (4700) NOTE: Occurrence of issue has been reduced. Applicable to XLEe/XLTe only | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved ethernet port lock up issues (8464/7052/7508) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage (alarms configured with unicode strings) via web designer model, device was rebooting (8288) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein device displayed hardfault error when modbus tcpip device list configured with more than 32 slaves was downloaded to device (7495/8531) NOTE: Applicable to XLEe/XLTe only | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein accessing webpages used to display frequent "connection timeout" (9869/7583) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein filename counter was not working properly if a file with screen capture is downloaded previously (5717) | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein frequent timeouts and reconnects was seen with units running EtherNet/IP server (8541) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved issue wherein there was communication issues in Modbus TCP when 6 or More Devices were used (8362) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | CSCAN 15.62 | August 2023 | Bug Fix | Resolved WebMI license details showing zero for users and screens field after power cycling the unit (9262) NOTE: Applicable to XLEe/XLTe only. | Bootloader | |
XLT/XLTe | Download Firmware 15.62 Release Notes | |||||
XLT/XLTe | CSCAN 15.60 | February 2023 | Bug Fix | Resolved issue when Full Duplex communication was not working properly with multiple slaves connected. (7587) | Bootloader | |
XLT/XLTe | CSCAN 15.60 | February 2023 | Bug Fix | Applicable to XLEe / XLTe only Resolved issue when WebMI license details on System Menu were not retained if ethernet cable or microSD card was removed. (9554/1258) | Bootloader | |
XLTe only | CSCAN 15.58 | March 2022 | New Feature | Added support for alternative hardware components. | Bootloader | |
XLTe only | Download Firmware 15.58 Release Notes | |||||
XLT/XLTe | CSCAN 15.56 | September 2021 | Enhancement | WebMI status bits have been added for session Count - %SR101.5 to SR101.7. (4980) | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Bug Fix | Resolve issue when occasionally microSD card was not detecting / reading properly when card was plugged and unplugged repeatedly. (4703) | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved the following issues (5398) - a. Packets were getting delayed beyond the set update interval when the update interval option was selected in the Client Protocol b. Previous sockets were getting closed before sending the reconnect packet | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved WebMI issue that if previous sessions were not getting closed, then a connection timeout occurred during long run as max sessions were reached. (4980) | Bootloader | |
XLT/XLTe | CSCAN 15.56 | September 2021 | Bug Fix | Resolved issue when ModbusTCP communication was not starting until Reacquire Time had timed out during power up or occasionally when unit was moved from Idle to Run mode. (5042) | Bootloader | |
XLT/XLTe | Download Firmware 15.56 Release Notes | |||||
XLT/XLTe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when Modbus communication on MJ2 stops working and unit locks up. (2769) | Bootloader | |
XLT/XLTe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue where in Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
XLT/XLTe | CSCAN 15.54 | July 2021 | Bug Fix | Resolved issue when using the Report Editor, an extra | Bootloader | |
XLT/XLTe | Download Firmware 15.54 Release Notes | |||||
XLT/XLTe | CSCAN 15.52 | May 2021 | Enhancement | Increased ladder size from 256KB to 512KB. (4318) | Bootloader | |
XLT/XLTe | CSCAN 15.52 | May 2021 | Bug Fix | XLE/XLEe and XLT/XLTe only - Resolved issue where stepper count was off by 1 or 2 in second generation XLE. (4004) | Bootloader | |
XLTe only | CSCAN 15.52 | May 2021 | Bug Fix | XLEe and XLTe only - Resolved issue where email was not working if Modbus TCP was configured. (3711) | Bootloader | |
XLT/XLTe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where the unit was continuously rebooting when the downloaded program was configured with > %R2048 in PID block and placed in RUN mode. (4943) | Bootloader | |
XLT/XLTe | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where a unit was continuously rebooting when "Auto Tune" feature was enabled in PID block in Firmware 15.50. (5646) | Bootloader | |
XLT/XLTe | Download Firmware 15.52 Release Notes | |||||
XLT/XLTe | CSCAN 15.44 | January 2021 | Bug Fix | In rare cases, analog inputs of Model 5 I/O will not update at power up or can stop updating during operation. | Hardware rev TU and later | |
XLT/XLTe | CSCAN 15.44 | January 2021 | Bug Fix | Using the stepper count function will result in extra pulses beyond the setpoint. | Hardware rev TU and later | |
XLT/XLTe | CSCAN 15.44 | *NOTE: If upgrading from Firmware 15.40, a power cycle is required when the firmware upgrade is complete. | ||||
XLT/XLTe | Download Firmware 15.44 Release Notes | |||||
XLT/XLTe | CSCAN 15.24 | January 2020 | Bug Fix | Could not load 15.20 Firmware and new CPLD on new blank XLE units. | ||
XLT/XLTe | CSCAN 15.24 | January 2020 | * NOTE: Does not affect post-production units that are flashed with earlier versions | |||
XLT/XLTe | Download Firmware 15.24 Release Notes | |||||
XLT/XLTe | CSCAN 15.22 | October 2019 | Bug Fix | Added commands to the display update block for recovering from split screen. | ||
XLT/XLTe | Download Firmware 15.24 Release Notes | |||||
XLT only | CSCAN 15.18 | January 2019 | Bug Fix | Reduce unnecessary current draw (without power) on the Backup Battery. | Rev TA-UD | |
XLT only | Download PUN Notes for Power Loss Details | |||||
XLT only | Download Firmware 15.18 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
Download >Download Firmware 15.62 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | F-keys tied to switch screen coils would sometimes remain held during the screen switch until pressed again. (4668) NOTE: Applies to EXL6, EXLW and X5 only. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. | Bootloader, Cscape 9.90 SP4 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
XL4, EXL6 only | CSCAN 15.52 | May 2021 | Licensed Enhancement | J1939 - J1939 protocol may now be licensed and added in the field for all XL4, EXL6, EXLW and X5 products. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
EXL6, EXL10 only | CSCAN 15.52 | May 2021 | Bug Fix | EXL6, EXLW and EXL10 only. Corrected an issue where the unit was getting stuck on the bootloader screen during a firmware update. Unit can be recovered by using the XL Series Firmware Recovery package – available from Horner Automation Tech Support. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
XL4, EXL6, XL7, EXL10 | Download Firmware 15.52 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | DHCP and DNS Support | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | MQTT - Sparkplug (licensed feature) | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | IP default HE-WIFIUSB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | Local Date (Day) rolls back at month change | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.40 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue on internal I/O bus timing preventing the unit from shutting down properly and saving registers. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where a fast power cycle (less than 2 seconds) caused the unit to run on internal battery causing an improper shut down. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed a watchdog issue related to the Horner Wi-Fi module performing a mode change. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where some applications using the email feature with TLS enabled causing a watchdog reset. | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.34 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Enhancement | BACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Enhancement | Basic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Possible reset when copying large files from uSD to USB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Error using wildcards in Removable Media blocks | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed issue where format size of microSD was limited to 1GB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Alarms not displayed on web pages in WebMI | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | System exception for some programs due to issue with incorrect value for baud rate for J1939 | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed an issue that prevented login after download | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Date format changed to DD-Mon-YY in retentive trend playback | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Alarm object display did not show live refresh for WebMI | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Off Delay Timer output was energizing when no power was applied to Timer in first scan | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | HE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | When the password data object is set for user access object type, the visibility does not work as expected. | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.30 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.22 | June 2019 | Enhancement | Expanded the temperature range at which battery charging can occur. The Charging Temperature Range Table below lists these ambient temperature values by controller. Refer to the Horner Rechargeable Battery Operation Manual, MAN1142, for more details. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.22 | June 2019 | ||||
XL4, EXL6, XL7, EXL10 | Download Rechargeable Battery Operation Manual | |||||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.22 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
Download >Download Firmware 15.62 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | F-keys tied to switch screen coils would sometimes remain held during the screen switch until pressed again. (4668) NOTE: Applies to EXL6, EXLW and X5 only. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. | Bootloader, Cscape 9.90 SP4 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
XL4, EXL6 only | CSCAN 15.52 | May 2021 | Licensed Enhancement | J1939 - J1939 protocol may now be licensed and added in the field for all XL4, EXL6, EXLW and X5 products. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
EXL6, EXL10 only | CSCAN 15.52 | May 2021 | Bug Fix | EXL6, EXLW and EXL10 only. Corrected an issue where the unit was getting stuck on the bootloader screen during a firmware update. Unit can be recovered by using the XL Series Firmware Recovery package – available from Horner Automation Tech Support. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
XL4, EXL6, XL7, EXL10 | Download Firmware 15.52 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | DHCP and DNS Support | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | MQTT - Sparkplug (licensed feature) | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | IP default HE-WIFIUSB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | Local Date (Day) rolls back at month change | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.40 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue on internal I/O bus timing preventing the unit from shutting down properly and saving registers. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where a fast power cycle (less than 2 seconds) caused the unit to run on internal battery causing an improper shut down. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed a watchdog issue related to the Horner Wi-Fi module performing a mode change. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where some applications using the email feature with TLS enabled causing a watchdog reset. | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.34 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Enhancement | BACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Enhancement | Basic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Possible reset when copying large files from uSD to USB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Error using wildcards in Removable Media blocks | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed issue where format size of microSD was limited to 1GB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Alarms not displayed on web pages in WebMI | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | System exception for some programs due to issue with incorrect value for baud rate for J1939 | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed an issue that prevented login after download | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Date format changed to DD-Mon-YY in retentive trend playback | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Alarm object display did not show live refresh for WebMI | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Off Delay Timer output was energizing when no power was applied to Timer in first scan | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | HE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | When the password data object is set for user access object type, the visibility does not work as expected. | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.30 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.22 | June 2019 | Enhancement | Expanded the temperature range at which battery charging can occur. The Charging Temperature Range Table below lists these ambient temperature values by controller. Refer to the Horner Rechargeable Battery Operation Manual, MAN1142, for more details. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.22 | June 2019 | ||||
XL4, EXL6, XL7, EXL10 | Download Rechargeable Battery Operation Manual | |||||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.22 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
EXLW | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
EXLW | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
EXLW | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
EXLW | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
EXLW | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
EXLW | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
EXLW | CSCAN 15.62 | May 2023 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
EXLW | CSCAN 15.62 | May 2023 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
EXLW | Download >Download Firmware 15.62 Release Notes | |||||
EXLW | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
EXLW | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
EXLW | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
EXLW | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
EXLW | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
EXLW | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
EXLW | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | F-keys tied to switch screen coils would sometimes remain held during the screen switch until pressed again. (4668) NOTE: Applies to EXL6, EXLW and X5 only. | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | Model displayed incorrectly on the EXLW units. (6005) NOTE: Resolved for CsCAN models. | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
EXLW | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
EXLW | Download Firmware 15.54 Release Notes | |||||
EXLW | CSCAN 15.52 | May 2021 | Enhancement | Added support for CANopen, J1939 and DeviceNet to the HE-EXLW products. (4637) | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. | Bootloader, Cscape 9.90 SP4 | |
EXLW | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
EXLW | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Licensed Enhancement | J1939 - J1939 protocol may now be licensed and added in the field for all XL4, EXL6, EXLW and X5 products. | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | EXL6, EXLW and EXL10 only. Corrected an issue where the unit was getting stuck on the bootloader screen during a firmware update. Unit can be recovered by using the XL Series Firmware Recovery package – available from Horner Automation Tech Support. | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | EXLW only - Corrected the part numbers for the reported EXLW device type (3954). | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
EXLW | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
EXLW | Download Firmware 15.52 Release Notes | |||||
EXLW | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | ||
EXLW | CSCAN 15.40 | July 2020 | Enhancement | DHCP and DNS Support | ||
EXLW | CSCAN 15.40 | July 2020 | Enhancement | MQTT - Sparkplug (licensed feature) | ||
EXLW | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | ||
EXLW | CSCAN 15.40 | July 2020 | Enhancement | Added X5 Factory Calibration | ||
EXLW | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
EXLW | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
EXLW | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
EXLW | CSCAN 15.40 | July 2020 | Bug Fix | IP default HE-WIFIUSB | ||
EXLW | CSCAN 15.40 | July 2020 | Bug Fix | Local Date (Day) rolls back at month change | ||
EXLW | Download Firmware 15.40 Release Notes | |||||
EXLW | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue on internal I/O bus timing preventing the unit from shutting down properly and saving registers. | ||
EXLW | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where a fast power cycle (less than 2 seconds) caused the unit to run on internal battery causing an improper shut down. | ||
EXLW | CSCAN 15.34 | June 2020 | Bug Fix | Fixed a watchdog issue related to the Horner Wi-Fi module performing a mode change. | ||
EXLW | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where some applications using the email feature with TLS enabled causing a watchdog reset. | ||
EXLW | Download Firmware 15.40 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
Download >Download Firmware 15.62 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | F-keys tied to switch screen coils would sometimes remain held during the screen switch until pressed again. (4668) NOTE: Applies to EXL6, EXLW and X5 only. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. | Bootloader, Cscape 9.90 SP4 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
XL4, EXL6 only | CSCAN 15.52 | May 2021 | Licensed Enhancement | J1939 - J1939 protocol may now be licensed and added in the field for all XL4, EXL6, EXLW and X5 products. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
EXL6, EXL10 only | CSCAN 15.52 | May 2021 | Bug Fix | EXL6, EXLW and EXL10 only. Corrected an issue where the unit was getting stuck on the bootloader screen during a firmware update. Unit can be recovered by using the XL Series Firmware Recovery package – available from Horner Automation Tech Support. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
XL4, EXL6, XL7, EXL10 | Download Firmware 15.52 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | DHCP and DNS Support | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | MQTT - Sparkplug (licensed feature) | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | IP default HE-WIFIUSB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | Local Date (Day) rolls back at month change | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.40 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue on internal I/O bus timing preventing the unit from shutting down properly and saving registers. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where a fast power cycle (less than 2 seconds) caused the unit to run on internal battery causing an improper shut down. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed a watchdog issue related to the Horner Wi-Fi module performing a mode change. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where some applications using the email feature with TLS enabled causing a watchdog reset. | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.34 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Enhancement | BACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Enhancement | Basic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Possible reset when copying large files from uSD to USB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Error using wildcards in Removable Media blocks | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed issue where format size of microSD was limited to 1GB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Alarms not displayed on web pages in WebMI | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | System exception for some programs due to issue with incorrect value for baud rate for J1939 | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed an issue that prevented login after download | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Date format changed to DD-Mon-YY in retentive trend playback | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Alarm object display did not show live refresh for WebMI | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Off Delay Timer output was energizing when no power was applied to Timer in first scan | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | HE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | When the password data object is set for user access object type, the visibility does not work as expected. | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.30 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.22 | June 2019 | Enhancement | Expanded the temperature range at which battery charging can occur. The Charging Temperature Range Table below lists these ambient temperature values by controller. Refer to the Horner Rechargeable Battery Operation Manual, MAN1142, for more details. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.22 | June 2019 | ||||
XL4, EXL6, XL7, EXL10 | Download Rechargeable Battery Operation Manual | |||||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.22 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
XL4, EXL6, EXLW, XL7, EXL10 | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
XL4, EXL6, EXLW, XL7, EXL10 | CSCAN 15.62 | May 2023 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
Download >Download Firmware 15.62 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | F-keys tied to switch screen coils would sometimes remain held during the screen switch until pressed again. (4668) NOTE: Applies to EXL6, EXLW and X5 only. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. | Bootloader, Cscape 9.90 SP4 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
XL4, EXL6 only | CSCAN 15.52 | May 2021 | Licensed Enhancement | J1939 - J1939 protocol may now be licensed and added in the field for all XL4, EXL6, EXLW and X5 products. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
EXL6, EXL10 only | CSCAN 15.52 | May 2021 | Bug Fix | EXL6, EXLW and EXL10 only. Corrected an issue where the unit was getting stuck on the bootloader screen during a firmware update. Unit can be recovered by using the XL Series Firmware Recovery package – available from Horner Automation Tech Support. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
XL4, EXL6, XL7, EXL10 | Download Firmware 15.52 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | DHCP and DNS Support | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | MQTT - Sparkplug (licensed feature) | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | IP default HE-WIFIUSB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.40 | July 2020 | Bug Fix | Local Date (Day) rolls back at month change | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.40 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue on internal I/O bus timing preventing the unit from shutting down properly and saving registers. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where a fast power cycle (less than 2 seconds) caused the unit to run on internal battery causing an improper shut down. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed a watchdog issue related to the Horner Wi-Fi module performing a mode change. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where some applications using the email feature with TLS enabled causing a watchdog reset. | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.34 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Enhancement | BACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Enhancement | Basic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Possible reset when copying large files from uSD to USB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Error using wildcards in Removable Media blocks | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed issue where format size of microSD was limited to 1GB | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Alarms not displayed on web pages in WebMI | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | System exception for some programs due to issue with incorrect value for baud rate for J1939 | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Fixed an issue that prevented login after download | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Date format changed to DD-Mon-YY in retentive trend playback | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Alarm object display did not show live refresh for WebMI | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | Off Delay Timer output was energizing when no power was applied to Timer in first scan | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | HE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.30 | October 2019 | Bug Fix | When the password data object is set for user access object type, the visibility does not work as expected. | ||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.30 Release Notes | |||||
XL4, EXL6, XL7, EXL10 | CSCAN 15.22 | June 2019 | Enhancement | Expanded the temperature range at which battery charging can occur. The Charging Temperature Range Table below lists these ambient temperature values by controller. Refer to the Horner Rechargeable Battery Operation Manual, MAN1142, for more details. | ||
XL4, EXL6, XL7, EXL10 | CSCAN 15.22 | June 2019 | ||||
XL4, EXL6, XL7, EXL10 | Download Rechargeable Battery Operation Manual | |||||
XL4, EXL6, XL7, EXL10 | Download Firmware 15.22 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader | |
XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was able to login via user access object (10016) | Bootloader | |
XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages (9045) | Bootloader | |
XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved following issues related to Automatic Recovery procedure - a. Application program mainly the Configuration and Ladder sizes were zero, and the OCS was going to idle mode. b. System settings were not getting restored from the Backup (6206) | Bootloader | |
XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved rebooting of device continuously after a power cycle if DHCP was enabled in LAN2 (8539) | Bootloader | |
XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue wherein Modbus client was sending zero value when holding register is not zero (8035) | Bootloader | |
XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue where CAN2 stops working after several power cycles (8612) | Bootloader | |
XL15+ | CSCAN 15.60 | October 2023 | Bug Fix | Resolved issue wherein emails sent from OCS was being treated as spams due to email header missing time zone (9105) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) to avoid opening of password dialog when PGM is loaded via SR bits. (8345) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Enhancement | HSC IO filter support added | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue where in whole SD card contents were getting wiped out if RM delete block was configured with "Blank filename" or "only directory mentioned with \" as the last character. (7367/7300) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if the battery fails, license will be valid (for lifetime licenses). (3429) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein conversion blocks were working only for ODD register number and was failing for EVEN register number. (6233) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein device was displaying exception when used Copy CF block – IEC. (7631) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein when user access alarms webpage via web designer model, device displayed Hardfault error. (8288) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue where in Q1 output was not going TRUE after online change. (8713) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue where in Modbus Client protocol stops working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein Automatic Recovery procedure was not working always. (6206) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue when battery was missing and in non-Automatic Restore mode, the application was not getting deleted, and registers displayed some random values. (6207) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein without releasing initial touch on screen, user was able to operate multiple touches with the initial touch being still active. (1241) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein timer output was turning on at startup. (7639) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue where alarm history in WebMI was not listing all alarms. (1643) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device (XLPlus) restart to resume communications. (8635) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein when user exits from Online Change mode, CAN port 1 SmartStix were temporarily showing not configured in the status. (9951) | Bootloader | |
XL15+ | CSCAN 15.58 | June 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader | |
XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Implemented read only file system. | Bootloader | |
XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when F-keys tied to switch screen coils, sometimes the F-key would remain held during the screen switch until pressed again. (4668) | Bootloader | |
XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when Modbus TCP communication would stop due to DHCP lease time expiring. (6101) | Bootloader | |
XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when FTP of files to OCS were failing under certain conditions. (4593/4792) | Bootloader | |
XL15+ | CSCAN 15.54 | February 2022 | Bug Fix | Resolved issue when unit would lose communication with Cscape over Ethernet when the unit was left running for multiple days. (4700) | Bootloader | |
XL15+ | Download Firmware 15.54 Release Notes | |||||
XL15+ | CSCAN 15.52 | May 2021 | Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. Requires Cscape 9.90 SP4. | Bootloader | |
XL15+ | CSCAN 15.52 | May 2021 | Enhancement | Enhanced IEC Licensing – Features added. Requires Cscape 9.90 SP4. | Bootloader | |
XL15+ | CSCAN 15.52 | May 2021 | Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
XL15+ | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. (2155) | Bootloader | |
XL15+ | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Cscape was not able to connect to XL+ via ethernet after leaving the unit running for multiple days although pinging was functional. (4700) | Bootloader | |
XL15+ | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where in NTP server was skipping a day on New Year’s Day. (4910) | Bootloader | |
XL15+ | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where in navigating to screen configured with objects which had overlapping of data value on legend was causing watch dog trip. (5351) | Bootloader | |
XL15+ | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working (Port loopback test failed on MJ1, MJ2 and MJ3 ports). (5713) | Bootloader | |
XL15+ | Download Firmware 15.52 Release Notes | |||||
XL+ | CSCAN 15.42 | February 2021 | Enhancement | Support has been provided to add user customized keyslide image. | ||
XL+ | CSCAN 15.42 | February 2021 | Bug Fix | Resolved screen capture issue where the captured images display incorrect colors when viewed on a PC screen. | ||
XL+ | CSCAN 15.42 | February 2021 | Bug Fix | Resolved an issue where an FTP Failure error message is displayed while publishing webpages (WebMI). | ||
XL+ | CSCAN 15.42 | February 2021 | Bug Fix | Resolved an issue where the XL+ suffers a system exception under the following conditions: 1. 2nd user is logged in to WebMI webpages 2. 2nd user attempts to access a webpage that has an embedded Alarm History object. 3. Controller is currently displaying the same page | ||
XL+ | Download Firmware 15.42 Release Notes | |||||
XL+ | CSCAN 15.40 | July 2020 | Enhancement | Downloadable protocol enable/disable options now available for full Network and also for individual devices | Cscape 9.90 SP3 | |
XL+ | CSCAN 15.40 | July 2020 | Enhancement | DHCP and DNS Support | Cscape 9.90 SP3 | |
XL+ | CSCAN 15.40 | July 2020 | Enhancement | MQTT - Sparkplug (licensed feature) | Cscape 9.90 SP3 | |
XL+ | CSCAN 15.40 | July 2020 | Enhancement | Structure support in RM blocks | Cscape 9.90 SP3 | |
XL+ | CSCAN 15.40 | July 2020 | Bug Fix | Setpoints not loaded when loading .pgm file in controller with Cscape 9.90 SP1 & SP2 | Cscape 9.90 SP3 | |
XL+ | CSCAN 15.40 | July 2020 | Bug Fix | CsCAN ladder blocks can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL+ | CSCAN 15.40 | July 2020 | Bug Fix | PID blocks, Modbus master and slave blocks, Alarm block can now use registers greater than %R2048 | Cscape 9.90 SP3 | |
XL+ | CSCAN 15.40 | July 2020 | Bug Fix | Fixed FPGA error (XL+ with EipcClient protocol 4.00 would not download to controller) | Cscape 9.90 SP3 | |
XL+ | Download Firmware 15.40 Release Notes | |||||
XL+ | CSCAN 15.32 | February 2020 | Enhancement | Wi-Fi Support | ||
XL+ | CSCAN 15.32 | February 2020 | Enhancement | Live graphics update support | ||
XL+ | CSCAN 15.32 | February 2020 | Enhancement | Screen Mirroring (Dual Display) support using mini display port connector | ||
XL+ | CSCAN 15.32 | February 2020 | Enhancement | Text wrap on Button text | ||
XL+ | CSCAN 15.32 | February 2020 | Enhancement | New Gauge Needles | ||
XL+ | CSCAN 15.32 | February 2020 | Enhancement | Set CAN ID function block | ||
XL+ | CSCAN 15.32 | February 2020 | Enhancement | .Array move with datatypes and in advanced ladder with tags | ||
XL+ | CSCAN 15.32 | February 2020 | Enhancement | Added support for 500K and 1M baud in J1939 protocol | ||
XL+ | CSCAN 15.32 | February 2020 | Enhancement | NTP protocol for XL+ | ||
XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Font colors for buttons on XL+ | ||
XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Word security is misspelled on screen while downloading | ||
XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Improved compatibility with microSD cards | ||
XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Corrected EGD issue | ||
XL+ | CSCAN 15.32 | February 2020 | Bug Fix | First letter of attached filename being cut off after email send. | ||
XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Artifacts on screen objects with non-visible screen objects overlayed | ||
XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Graphic display issue on XL+ featuring text overlayed on bitmaps and screen jumps | ||
XL+ | CSCAN 15.32 | February 2020 | Bug Fix | Corrected issue where unit occasionally loses program if Load Program is following immediately by power cycle. | ||
XL+ | NOTE: Firmware 15.32 is required for hardware CD for Model 5 only. Older firmware will not function on this newer hardware if thermocouple inputs are used. | |||||
XL+ | Download Firmware 15.32 Release Notes |
XL PRIME SERIES
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
Prime XL15 only | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved possible condition where device could get stuck on splash screen after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved %SR181 and %SR182 not updating for Unacknowledged and Active alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved an unintended condition in which the display could be kept on by a mini-USB connection even when 24V supply to the controller was removed. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved title bar of password object showing nonsense when Unicode fonts were created. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved WebMI alarm history page not listing the RTN alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CANOpen blocks not working when CAN1 port was configured as CANOpen and CAN2 port as J1939. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new OCSIO modules - DQM606, DIM610 and CNX100; NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards. %SR104 – 32bit %SR for storing password of program which is currently running.%SR106 – 32bit %SR for storing password of program which is being loaded | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added Ethernet dongle status register - %S15 (10185) NOTE: When the Ethernet dongle is connected, %S15 bit will be enabled, once it is removed, %S15 bit will be disabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Feature request to add a reset bit for EtherNet/IP Server. (8633) NOTE: SR156.3 for Ethernet/Ip protocol Lan1 reset. SR153.3 for Ethernet/Ip protocol Lan2 reset. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein MQTT NBIRTH/NDEATH packets were causing loss of communications (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spams (9105) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unit was not showing negative value when CPU temperature was below Zero deg C and min/max value would wrap around (8587) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was working (10016) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured (8765) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device restart to resume communications (8635) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue when the X5 Prime was reporting bad clock/battery and would sometimes default the clock. (9903) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue where audio was not functional when 105 IO card was being used on XL7/XL10 Prime models. This also solves slow boot issue. (7530) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.22 | March 2023 | Bug Fix | Resolved issue where XL Prime units could drop out of RUN mode due to a logic error. (9527) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | OCSIO Support has been added. This requires Cscape 9.90 SP8 onwards. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Improved upgrade procedure for non-bootable microSD card option. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Added "Replace System Graphics" support in System recovery screen for customizing slide key* and splash screen. *Slide key customization applicable to XLW Prime and X5 Prime only. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Bug Fix | Resolved touch and bootup issue at low temperature. (8929) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.16 | October 2022 | Bug Fix | Fixed issue where incorrect data was being populated into the upper word for High Speed Counter inputs. (8706) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | Support added for LAN2 when using included USB Dongle for XL7 and XL10 Prime models only. Requires Cscape 9.9 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | New X5 Prime model has been added. NOTE: Requires Cscape 9.90 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Resolved issue when conversion blocks were working for ODD register numbers only and was failing EVEN register number in Register-Based Advanced Ladder. (6233) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Serial Modbus communication has been improved for higher baud rates. (7674) | Bootloader, Cscape 9.90 SP8 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
Prime XL15 only | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved possible condition where device could get stuck on splash screen after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved %SR181 and %SR182 not updating for Unacknowledged and Active alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved an unintended condition in which the display could be kept on by a mini-USB connection even when 24V supply to the controller was removed. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved title bar of password object showing nonsense when Unicode fonts were created. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved WebMI alarm history page not listing the RTN alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CANOpen blocks not working when CAN1 port was configured as CANOpen and CAN2 port as J1939. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new OCSIO modules - DQM606, DIM610 and CNX100; NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards. %SR104 – 32bit %SR for storing password of program which is currently running.%SR106 – 32bit %SR for storing password of program which is being loaded | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added Ethernet dongle status register - %S15 (10185) NOTE: When the Ethernet dongle is connected, %S15 bit will be enabled, once it is removed, %S15 bit will be disabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Feature request to add a reset bit for EtherNet/IP Server. (8633) NOTE: SR156.3 for Ethernet/Ip protocol Lan1 reset. SR153.3 for Ethernet/Ip protocol Lan2 reset. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein MQTT NBIRTH/NDEATH packets were causing loss of communications (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spams (9105) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unit was not showing negative value when CPU temperature was below Zero deg C and min/max value would wrap around (8587) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was working (10016) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured (8765) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device restart to resume communications (8635) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue when the X5 Prime was reporting bad clock/battery and would sometimes default the clock. (9903) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue where audio was not functional when 105 IO card was being used on XL7/XL10 Prime models. This also solves slow boot issue. (7530) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.22 | March 2023 | Bug Fix | Resolved issue where XL Prime units could drop out of RUN mode due to a logic error. (9527) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | OCSIO Support has been added. This requires Cscape 9.90 SP8 onwards. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Improved upgrade procedure for non-bootable microSD card option. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Added "Replace System Graphics" support in System recovery screen for customizing slide key* and splash screen. *Slide key customization applicable to XLW Prime and X5 Prime only. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Bug Fix | Resolved touch and bootup issue at low temperature. (8929) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.16 | October 2022 | Bug Fix | Fixed issue where incorrect data was being populated into the upper word for High Speed Counter inputs. (8706) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | Support added for LAN2 when using included USB Dongle for XL7 and XL10 Prime models only. Requires Cscape 9.9 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | New X5 Prime model has been added. NOTE: Requires Cscape 9.90 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Resolved issue when conversion blocks were working for ODD register numbers only and was failing EVEN register number in Register-Based Advanced Ladder. (6233) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Serial Modbus communication has been improved for higher baud rates. (7674) | Bootloader, Cscape 9.90 SP8 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
Prime XL15 only | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved possible condition where device could get stuck on splash screen after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved %SR181 and %SR182 not updating for Unacknowledged and Active alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved an unintended condition in which the display could be kept on by a mini-USB connection even when 24V supply to the controller was removed. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved title bar of password object showing nonsense when Unicode fonts were created. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved WebMI alarm history page not listing the RTN alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CANOpen blocks not working when CAN1 port was configured as CANOpen and CAN2 port as J1939. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new OCSIO modules - DQM606, DIM610 and CNX100; NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards. %SR104 – 32bit %SR for storing password of program which is currently running.%SR106 – 32bit %SR for storing password of program which is being loaded | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added Ethernet dongle status register - %S15 (10185) NOTE: When the Ethernet dongle is connected, %S15 bit will be enabled, once it is removed, %S15 bit will be disabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Feature request to add a reset bit for EtherNet/IP Server. (8633) NOTE: SR156.3 for Ethernet/Ip protocol Lan1 reset. SR153.3 for Ethernet/Ip protocol Lan2 reset. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein MQTT NBIRTH/NDEATH packets were causing loss of communications (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spams (9105) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unit was not showing negative value when CPU temperature was below Zero deg C and min/max value would wrap around (8587) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was working (10016) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured (8765) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device restart to resume communications (8635) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue when the X5 Prime was reporting bad clock/battery and would sometimes default the clock. (9903) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue where audio was not functional when 105 IO card was being used on XL7/XL10 Prime models. This also solves slow boot issue. (7530) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.22 | March 2023 | Bug Fix | Resolved issue where XL Prime units could drop out of RUN mode due to a logic error. (9527) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | OCSIO Support has been added. This requires Cscape 9.90 SP8 onwards. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Improved upgrade procedure for non-bootable microSD card option. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Added "Replace System Graphics" support in System recovery screen for customizing slide key* and splash screen. *Slide key customization applicable to XLW Prime and X5 Prime only. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Bug Fix | Resolved touch and bootup issue at low temperature. (8929) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.16 | October 2022 | Bug Fix | Fixed issue where incorrect data was being populated into the upper word for High Speed Counter inputs. (8706) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | Support added for LAN2 when using included USB Dongle for XL7 and XL10 Prime models only. Requires Cscape 9.9 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | New X5 Prime model has been added. NOTE: Requires Cscape 9.90 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Resolved issue when conversion blocks were working for ODD register numbers only and was failing EVEN register number in Register-Based Advanced Ladder. (6233) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Serial Modbus communication has been improved for higher baud rates. (7674) | Bootloader, Cscape 9.90 SP8 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
Prime XL15 only | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved possible condition where device could get stuck on splash screen after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved %SR181 and %SR182 not updating for Unacknowledged and Active alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved an unintended condition in which the display could be kept on by a mini-USB connection even when 24V supply to the controller was removed. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved title bar of password object showing nonsense when Unicode fonts were created. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved WebMI alarm history page not listing the RTN alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CANOpen blocks not working when CAN1 port was configured as CANOpen and CAN2 port as J1939. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new OCSIO modules - DQM606, DIM610 and CNX100; NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards. %SR104 – 32bit %SR for storing password of program which is currently running.%SR106 – 32bit %SR for storing password of program which is being loaded | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added Ethernet dongle status register - %S15 (10185) NOTE: When the Ethernet dongle is connected, %S15 bit will be enabled, once it is removed, %S15 bit will be disabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Feature request to add a reset bit for EtherNet/IP Server. (8633) NOTE: SR156.3 for Ethernet/Ip protocol Lan1 reset. SR153.3 for Ethernet/Ip protocol Lan2 reset. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein MQTT NBIRTH/NDEATH packets were causing loss of communications (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spams (9105) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unit was not showing negative value when CPU temperature was below Zero deg C and min/max value would wrap around (8587) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was working (10016) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured (8765) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device restart to resume communications (8635) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue when the X5 Prime was reporting bad clock/battery and would sometimes default the clock. (9903) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue where audio was not functional when 105 IO card was being used on XL7/XL10 Prime models. This also solves slow boot issue. (7530) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.22 | March 2023 | Bug Fix | Resolved issue where XL Prime units could drop out of RUN mode due to a logic error. (9527) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | OCSIO Support has been added. This requires Cscape 9.90 SP8 onwards. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Improved upgrade procedure for non-bootable microSD card option. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Added "Replace System Graphics" support in System recovery screen for customizing slide key* and splash screen. *Slide key customization applicable to XLW Prime and X5 Prime only. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Bug Fix | Resolved touch and bootup issue at low temperature. (8929) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.16 | October 2022 | Bug Fix | Fixed issue where incorrect data was being populated into the upper word for High Speed Counter inputs. (8706) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | Support added for LAN2 when using included USB Dongle for XL7 and XL10 Prime models only. Requires Cscape 9.9 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | New X5 Prime model has been added. NOTE: Requires Cscape 9.90 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Resolved issue when conversion blocks were working for ODD register numbers only and was failing EVEN register number in Register-Based Advanced Ladder. (6233) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Serial Modbus communication has been improved for higher baud rates. (7674) | Bootloader, Cscape 9.90 SP8 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
Prime XL15 only | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved possible condition where device could get stuck on splash screen after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved %SR181 and %SR182 not updating for Unacknowledged and Active alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved an unintended condition in which the display could be kept on by a mini-USB connection even when 24V supply to the controller was removed. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved title bar of password object showing nonsense when Unicode fonts were created. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved WebMI alarm history page not listing the RTN alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CANOpen blocks not working when CAN1 port was configured as CANOpen and CAN2 port as J1939. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new OCSIO modules - DQM606, DIM610 and CNX100; NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards. %SR104 – 32bit %SR for storing password of program which is currently running.%SR106 – 32bit %SR for storing password of program which is being loaded | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added Ethernet dongle status register - %S15 (10185) NOTE: When the Ethernet dongle is connected, %S15 bit will be enabled, once it is removed, %S15 bit will be disabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Feature request to add a reset bit for EtherNet/IP Server. (8633) NOTE: SR156.3 for Ethernet/Ip protocol Lan1 reset. SR153.3 for Ethernet/Ip protocol Lan2 reset. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein MQTT NBIRTH/NDEATH packets were causing loss of communications (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spams (9105) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unit was not showing negative value when CPU temperature was below Zero deg C and min/max value would wrap around (8587) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was working (10016) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured (8765) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device restart to resume communications (8635) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue when the X5 Prime was reporting bad clock/battery and would sometimes default the clock. (9903) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue where audio was not functional when 105 IO card was being used on XL7/XL10 Prime models. This also solves slow boot issue. (7530) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.22 | March 2023 | Bug Fix | Resolved issue where XL Prime units could drop out of RUN mode due to a logic error. (9527) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | OCSIO Support has been added. This requires Cscape 9.90 SP8 onwards. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Improved upgrade procedure for non-bootable microSD card option. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Added "Replace System Graphics" support in System recovery screen for customizing slide key* and splash screen. *Slide key customization applicable to XLW Prime and X5 Prime only. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Bug Fix | Resolved touch and bootup issue at low temperature. (8929) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.16 | October 2022 | Bug Fix | Fixed issue where incorrect data was being populated into the upper word for High Speed Counter inputs. (8706) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | Support added for LAN2 when using included USB Dongle for XL7 and XL10 Prime models only. Requires Cscape 9.9 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | New X5 Prime model has been added. NOTE: Requires Cscape 9.90 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Resolved issue when conversion blocks were working for ODD register numbers only and was failing EVEN register number in Register-Based Advanced Ladder. (6233) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Serial Modbus communication has been improved for higher baud rates. (7674) | Bootloader, Cscape 9.90 SP8 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
Prime XL15 only | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved possible condition where device could get stuck on splash screen after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved %SR181 and %SR182 not updating for Unacknowledged and Active alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved an unintended condition in which the display could be kept on by a mini-USB connection even when 24V supply to the controller was removed. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved title bar of password object showing nonsense when Unicode fonts were created. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved WebMI alarm history page not listing the RTN alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CANOpen blocks not working when CAN1 port was configured as CANOpen and CAN2 port as J1939. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new OCSIO modules - DQM606, DIM610 and CNX100; NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards. %SR104 – 32bit %SR for storing password of program which is currently running.%SR106 – 32bit %SR for storing password of program which is being loaded | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added Ethernet dongle status register - %S15 (10185) NOTE: When the Ethernet dongle is connected, %S15 bit will be enabled, once it is removed, %S15 bit will be disabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Feature request to add a reset bit for EtherNet/IP Server. (8633) NOTE: SR156.3 for Ethernet/Ip protocol Lan1 reset. SR153.3 for Ethernet/Ip protocol Lan2 reset. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein MQTT NBIRTH/NDEATH packets were causing loss of communications (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spams (9105) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unit was not showing negative value when CPU temperature was below Zero deg C and min/max value would wrap around (8587) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was working (10016) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured (8765) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device restart to resume communications (8635) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue when the X5 Prime was reporting bad clock/battery and would sometimes default the clock. (9903) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue where audio was not functional when 105 IO card was being used on XL7/XL10 Prime models. This also solves slow boot issue. (7530) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.22 | March 2023 | Bug Fix | Resolved issue where XL Prime units could drop out of RUN mode due to a logic error. (9527) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | OCSIO Support has been added. This requires Cscape 9.90 SP8 onwards. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Improved upgrade procedure for non-bootable microSD card option. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Added "Replace System Graphics" support in System recovery screen for customizing slide key* and splash screen. *Slide key customization applicable to XLW Prime and X5 Prime only. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Bug Fix | Resolved touch and bootup issue at low temperature. (8929) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.16 | October 2022 | Bug Fix | Fixed issue where incorrect data was being populated into the upper word for High Speed Counter inputs. (8706) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | Support added for LAN2 when using included USB Dongle for XL7 and XL10 Prime models only. Requires Cscape 9.9 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | New X5 Prime model has been added. NOTE: Requires Cscape 9.90 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Resolved issue when conversion blocks were working for ODD register numbers only and was failing EVEN register number in Register-Based Advanced Ladder. (6233) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Serial Modbus communication has been improved for higher baud rates. (7674) | Bootloader, Cscape 9.90 SP8 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Enhancement | Retain variable support added for variable-based advanced ladder Note: This requires Cscape version 10 onwards | ||
Prime XL15 only | CSCAN 17.02 | August 2024 | Enhancement | Added support to XL15 Prime model | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Fixed UTC time not updating when downloaded from Cscape using IEC or Enhanced IEC language | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved issue wherein CV value of a PID block was not getting updated when configured in Enhanced IEC program | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Adjacent status register was being affected when the first status register was updated in the Removable Media copy and delete blocks | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | • Resolved: NTP was not working when configured with IP address • Resolved: NTP server was skipping a day on new year’s if it was a leap year | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Performance of the device slows down and scan rate increases at higher temperatures | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight Savings Time was enabled | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: In read, the RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements | ||
Prime X5, XL4, XL6, XLW, XL7, XL10, XL15 | CSCAN 17.02 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu > View Status | ||
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved possible condition where device could get stuck on splash screen after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved %SR181 and %SR182 not updating for Unacknowledged and Active alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved an unintended condition in which the display could be kept on by a mini-USB connection even when 24V supply to the controller was removed. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved title bar of password object showing nonsense when Unicode fonts were created. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved WebMI alarm history page not listing the RTN alarms. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved CANOpen blocks not working when CAN1 port was configured as CANOpen and CAN2 port as J1939. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.32 | April 2024 | Bug Fix | Resolved ASCII string on the Allen Bradley PLC was being corrupted when second ASCII string was being transferred from controller. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new OCSIO modules - DQM606, DIM610 and CNX100; NOTE: CNX100 requires Cscape 9.90 SP10 onwards | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards. %SR104 – 32bit %SR for storing password of program which is currently running.%SR106 – 32bit %SR for storing password of program which is being loaded | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Added Ethernet dongle status register - %S15 (10185) NOTE: When the Ethernet dongle is connected, %S15 bit will be enabled, once it is removed, %S15 bit will be disabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Enhancement | Feature request to add a reset bit for EtherNet/IP Server. (8633) NOTE: SR156.3 for Ethernet/Ip protocol Lan1 reset. SR153.3 for Ethernet/Ip protocol Lan2 reset. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein user was not able to access files in a folder when FTP was configured as Read Only (10040) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein MQTT NBIRTH/NDEATH packets were causing loss of communications (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets. | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spams (9105) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unit was not showing negative value when CPU temperature was below Zero deg C and min/max value would wrap around (8587) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration was working (10016) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured (8765) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.30 | July 2023 | Bug Fix | Resolved issue wherein unplugging and plugging LAN cable from ETX200 base was not resuming communication on their own and required device restart to resume communications (8635) | Bootloader, Cscape 9.90 SP9 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue when the X5 Prime was reporting bad clock/battery and would sometimes default the clock. (9903) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.28 | May 2023 | Bug Fix | Resolved issue where audio was not functional when 105 IO card was being used on XL7/XL10 Prime models. This also solves slow boot issue. (7530) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.22 | March 2023 | Bug Fix | Resolved issue where XL Prime units could drop out of RUN mode due to a logic error. (9527) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | OCSIO Support has been added. This requires Cscape 9.90 SP8 onwards. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Improved upgrade procedure for non-bootable microSD card option. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Enhancement | Added "Replace System Graphics" support in System recovery screen for customizing slide key* and splash screen. *Slide key customization applicable to XLW Prime and X5 Prime only. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.20 | March 2023 | Bug Fix | Resolved touch and bootup issue at low temperature. (8929) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.16 | October 2022 | Bug Fix | Fixed issue where incorrect data was being populated into the upper word for High Speed Counter inputs. (8706) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | Support added for LAN2 when using included USB Dongle for XL7 and XL10 Prime models only. Requires Cscape 9.9 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Enhancement | New X5 Prime model has been added. NOTE: Requires Cscape 9.90 SP8 or higher. | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Resolved issue when conversion blocks were working for ODD register numbers only and was failing EVEN register number in Register-Based Advanced Ladder. (6233) | Bootloader, Cscape 9.90 SP8 or higher | |
Prime XL4, XL6, XLW, XL7, XL10, X5 | CSCAN 16.14 | September 2022 | Bug Fix | Serial Modbus communication has been improved for higher baud rates. (7674) | Bootloader, Cscape 9.90 SP8 or higher |
CANVAS SERIES
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: At times, some programs were becoming corrupted or losing graphics and the unit displayed “Invalid graphics” after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Device would freeze sometimes at “controller Fw-xx.xx.xxx" screen after power cycle. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Canvas value of a PID block was not updating when configured in Enhanced IEC program. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: RTC time was being incremented by one (1) hour per power cycle when Daylight savings time was enabled. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: NTP server was skipping a day on New Year's Day if it was a leap year. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Protocol size was displayed as +++++++ for BACNet MSTP server in System Menu | View Status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.04 | August 2024 | Bug Fix | Resolved: Read RM block was reading entire elements / data for an ASCII data type instead of reading only the configured number of elements. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 10D only | 17.04 | August 2024 | Bug Fix | Resolved USB Type C communication not working on Canvas 10D model. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added build version and firmware version in system menu | view status. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added limitations for Enhanced IEC Removable media Write and Read blocks to resolve the screen calibration being corrupted / system exception was being obtained when data was being written beyond 128 words (%M2048) using write removable media block | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Added support for using external modem as client with modem blocks. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved MAC ID was not being displayed in LAN2 when USB to ethernet dongle was used. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved Modbus Client sending zero value when Holding Register was not zero. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved screen calibration corruption when data was being written beyond 128 words (%M2048) that was using the Write removable media block. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved the following issues: • UTC time not being updated when downloaded from Cscape. • Default audio volume was too low when compared with previous firmware versions. Note: UTC time will not be updated when downloaded from Cscape using IEC/Enhanced IEC language. | Bootloader, Cscape 9.90 SP9 or higher | |
Canvas 4, 5, 7, 7D, 10D | 17.00 | July 2024 | Enhancement | Resolved CAN2 stops working after several power cycles. | Bootloader, Cscape 9.90 SP9 or higher |
RCC SERIES
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
RCC Series | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
RCC Series | CSCAN 15.62 | May 2023 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
RCC Series | Download >Download Firmware 15.62 Release Notes | |||||
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
RCC Series | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | RCC1410 & RCC8842 were not retaining retentive memory after power cycle when the battery voltage dropped below 4V. (6081) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
RCC Series | Download Firmware 15.54 Release Notes | |||||
RCC Series | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. | Bootloader, Cscape 9.90 SP4 | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | RCC only - Corrected an issue introduced in 15.30 which caused the legacy (pre-WebMI) webserver not to operate (3867). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | RCC only - Fixed an issue wherein it was not possible to recover RCCs with dead batteries (4674). | Bootloader | |
RCC 2414 only | CSCAN 15.52 | May 2021 | Bug Fix | RCC2414 only - Corrected an issue wherein the RCC was not updating the LAN2 EGD status (4024). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
RCC Series | Bug Fix | Download Firmware 15.52 Release Notes | ||||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue on internal I/O bus timing preventing the unit from shutting down properly and saving registers. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where a fast power cycle (less than 2 seconds) caused the unit to run on internal battery causing an improper shut down. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed a watchdog issue related to the Horner Wi-Fi module performing a mode change. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where some applications using the email feature with TLS enabled causing a watchdog reset. | ||
RCC Series | Download Firmware 15.40 Release Notes | |||||
RCC Series | CSCAN 15.30 | October 2019 | Enhancement | BACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process. | ||
RCC Series | CSCAN 15.30 | October 2019 | Enhancement | Basic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410. | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Possible reset when copying large files from uSD to USB | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Error using wildcards in Removable Media blocks | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Fixed issue where format size of microSD was limited to 1GB | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Alarms not displayed on web pages in WebMI | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | System exception for some programs due to issue with incorrect value for baud rate for J1939 | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Fixed an issue that prevented login after download | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Date format changed to DD-Mon-YY in retentive trend playback | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Alarm object display did not show live refresh for WebMI | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Off Delay Timer output was energizing when no power was applied to Timer in first scan | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | HE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | When the password data object is set for user access object type, the visibility does not work as expected. | ||
RCC Series | Download Firmware 15.30 Release Notes | |||||
RCC Series | CSCAN 15.22 | June 2019 | Enhancement | Expanded the temperature range at which battery charging can occur. The Charging Temperature Range Table below lists these ambient temperature values by controller. Refer to the Horner Rechargeable Battery Operation Manual, MAN1142, for more details. | ||
RCC Series | CSCAN 15.22 | June 2019 | ||||
RCC Series | Download Rechargeable Battery Operation Manual | |||||
RCC Series | Download Firmware 15.22 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
RCC Series | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
RCC Series | CSCAN 15.62 | May 2023 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
RCC Series | Download >Download Firmware 15.62 Release Notes | |||||
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
RCC Series | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | RCC1410 & RCC8842 were not retaining retentive memory after power cycle when the battery voltage dropped below 4V. (6081) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
RCC Series | Download Firmware 15.54 Release Notes | |||||
RCC Series | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. | Bootloader, Cscape 9.90 SP4 | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | RCC only - Corrected an issue introduced in 15.30 which caused the legacy (pre-WebMI) webserver not to operate (3867). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | RCC only - Fixed an issue wherein it was not possible to recover RCCs with dead batteries (4674). | Bootloader | |
RCC 2414 only | CSCAN 15.52 | May 2021 | Bug Fix | RCC2414 only - Corrected an issue wherein the RCC was not updating the LAN2 EGD status (4024). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
RCC Series | Bug Fix | Download Firmware 15.52 Release Notes | ||||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue on internal I/O bus timing preventing the unit from shutting down properly and saving registers. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where a fast power cycle (less than 2 seconds) caused the unit to run on internal battery causing an improper shut down. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed a watchdog issue related to the Horner Wi-Fi module performing a mode change. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where some applications using the email feature with TLS enabled causing a watchdog reset. | ||
RCC Series | Download Firmware 15.40 Release Notes | |||||
RCC Series | CSCAN 15.30 | October 2019 | Enhancement | BACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process. | ||
RCC Series | CSCAN 15.30 | October 2019 | Enhancement | Basic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410. | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Possible reset when copying large files from uSD to USB | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Error using wildcards in Removable Media blocks | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Fixed issue where format size of microSD was limited to 1GB | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Alarms not displayed on web pages in WebMI | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | System exception for some programs due to issue with incorrect value for baud rate for J1939 | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Fixed an issue that prevented login after download | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Date format changed to DD-Mon-YY in retentive trend playback | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Alarm object display did not show live refresh for WebMI | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Off Delay Timer output was energizing when no power was applied to Timer in first scan | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | HE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | When the password data object is set for user access object type, the visibility does not work as expected. | ||
RCC Series | Download Firmware 15.30 Release Notes | |||||
RCC Series | CSCAN 15.22 | June 2019 | Enhancement | Expanded the temperature range at which battery charging can occur. The Charging Temperature Range Table below lists these ambient temperature values by controller. Refer to the Horner Rechargeable Battery Operation Manual, MAN1142, for more details. | ||
RCC Series | CSCAN 15.22 | June 2019 | ||||
RCC Series | Download Rechargeable Battery Operation Manual | |||||
RCC Series | Download Firmware 15.22 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
RCC Series | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
RCC Series | CSCAN 15.62 | May 2023 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
RCC Series | Download >Download Firmware 15.62 Release Notes | |||||
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
RCC Series | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | RCC1410 & RCC8842 were not retaining retentive memory after power cycle when the battery voltage dropped below 4V. (6081) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
RCC Series | Download Firmware 15.54 Release Notes | |||||
RCC Series | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. | Bootloader, Cscape 9.90 SP4 | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | RCC only - Corrected an issue introduced in 15.30 which caused the legacy (pre-WebMI) webserver not to operate (3867). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | RCC only - Fixed an issue wherein it was not possible to recover RCCs with dead batteries (4674). | Bootloader | |
RCC 2414 only | CSCAN 15.52 | May 2021 | Bug Fix | RCC2414 only - Corrected an issue wherein the RCC was not updating the LAN2 EGD status (4024). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
RCC Series | Bug Fix | Download Firmware 15.52 Release Notes | ||||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue on internal I/O bus timing preventing the unit from shutting down properly and saving registers. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where a fast power cycle (less than 2 seconds) caused the unit to run on internal battery causing an improper shut down. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed a watchdog issue related to the Horner Wi-Fi module performing a mode change. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where some applications using the email feature with TLS enabled causing a watchdog reset. | ||
RCC Series | Download Firmware 15.40 Release Notes | |||||
RCC Series | CSCAN 15.30 | October 2019 | Enhancement | BACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process. | ||
RCC Series | CSCAN 15.30 | October 2019 | Enhancement | Basic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410. | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Possible reset when copying large files from uSD to USB | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Error using wildcards in Removable Media blocks | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Fixed issue where format size of microSD was limited to 1GB | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Alarms not displayed on web pages in WebMI | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | System exception for some programs due to issue with incorrect value for baud rate for J1939 | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Fixed an issue that prevented login after download | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Date format changed to DD-Mon-YY in retentive trend playback | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Alarm object display did not show live refresh for WebMI | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Off Delay Timer output was energizing when no power was applied to Timer in first scan | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | HE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | When the password data object is set for user access object type, the visibility does not work as expected. | ||
RCC Series | Download Firmware 15.30 Release Notes | |||||
RCC Series | CSCAN 15.22 | June 2019 | Enhancement | Expanded the temperature range at which battery charging can occur. The Charging Temperature Range Table below lists these ambient temperature values by controller. Refer to the Horner Rechargeable Battery Operation Manual, MAN1142, for more details. | ||
RCC Series | CSCAN 15.22 | June 2019 | ||||
RCC Series | Download Rechargeable Battery Operation Manual | |||||
RCC Series | Download Firmware 15.22 Release Notes |
PRODUCT | VERSION | RELEASE DATE | TYPE | DETAILS | REQUIREMENTS | |
---|---|---|---|---|---|---|
RCC Series | 15.64 | 9/18/23 | Enhancement | Added support for OCS-I/O (CNX100) modules. | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein device would PING for an invalid subnet mask configured. (8765) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein after multiple power cycle LAN2 IP would not work in RCC2414. (10106) NOTE: Applicable to RCC only | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein MQTT with CA certificate configured was not connecting to broker (10212) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein power cycle was required to recover the Modbus RTU communication when there was communication break while sending queries at high speed (10msec). (5843) | Bootloader, Cscape 9.90 SP10 | |
RCC Series | 15.64 | 9/18/23 | Bug Fix | Resolved issue wherein only limited number of users configured in user security configuration were working. (10016) | Bootloader, Cscape 9.90 SP10 | |
Download >Download Firmware 15.64 Release Notes | ||||||
RCC Series | CSCAN 15.62 | May 2023 | Enhancement | OCSIO support has been added along with new modules-DIM610 and DQM606. New modules require Cscape 9.90 SP9 onwards and OCSIO firmware | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Enhancement | Added new system registers for storing PGM password (%SR104 and %SR106) in order to avoid opening of password dialog when PGM is loaded via SR bits. (8345) NOTE: This requires Cscape 9.90 SP9 onwards %SR104–32bit %SR for storing password of program which is currently running %SR106–32bit %SR for storing password of program which is being loaded | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved ethernet port lock up issues. (8464) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved combining characters like Thai fonts were not displayed properly in Graphics Editor issue. (3878) NOTE: This requires Cscape 9.90 SP9 onwards. | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved device was displaying exception when used Copy_CF block – IEC issue. (7631) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved DeviceNet issue. It was not working until the cable from CAN2 port of master was unplugged and plugged back in. (7443) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Q1 output was not going TRUE after online change issue. (8713) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved Modbus Client protocol issue. It stopped working if more than 16 16-bit external registers / 8 32-bit external registers were used on screen. (9029) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved issue when %R values were not retained after power cycle when HSC preload function was used. (5995) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved alarm history was not listing all alarms on webpages issue. (1643) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved MQTT NBIRTH/NDEATH packets were causing loss of communications issue. (8642) NOTE: This requires Cscape 9.90 SP9 onwards. Added bdsequence number to the birth message packets | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved loss of communication issues with BACNet MSTP protocol for X5. (8881) NOTE: X5 only. | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved communication issues with ethernet SmartRail bases. (8625) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved CAN connectivity issues when unit was powered on with CAN port connected. (9064/9458) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved extra verbiage issue displayed in Alarm summary and history listings on webpages. (9045) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Added time zone information in email header to avoid email sent from OCS being treated as spam emails. (9105) | Bootloader | |
RCC Series | CSCAN 15.62 | May 2023 | Bug Fix | Resolved reset issue during opening and closing of port when Modbus RTU master sends query at high speed. (5843) NOTE: Device crash while opening and closing of serial port when Master sends Query at high speed is resolved, whereas power cycle of OCS may be required to recover the communication. | Bootloader | |
RCC Series | Download >Download Firmware 15.62 Release Notes | |||||
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | Added register selector support for client ID (MAC ID) in MQTT configuration. Requires Cscape 9.90 SP7 onwards. (7143) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | OCS-I/O Support. Requires Cscape 9.90 SP8 onwards. | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Enhancement | Modification in license checks due to vulnerability for EIEC, J1939, MQTT and WebMI. (7623) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when Conversion Blocks were functioning only for ODD register numbers and was failing for EVEN register numbers. (6233) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when scan rate was increasing when an email was not sent. (5876/7052/7508) | Bootloader | |
RCC Series | CSCAN 15.60 | November 2022 | Bug Fix | Resolved issue when the EGD status information was being displayed in wrong register - an address offset problem with EGD. (8461) | Bootloader | |
Download Firmware 15.54 Release Notes | ||||||
RCC Series | CSCAN 15.54 | March 2022 | Enhancement | Time-out of Modbus Slave and SRTP increased from 60 to 380 seconds. (5398) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | In the Report Editor, an extra | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Real to DINT conversion was giving incorrect result for some values. (5314) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Resolved System exception issue when downloaded BACNet protocol without configuring any devices / scan list. (5591) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | RCC1410 & RCC8842 were not retaining retentive memory after power cycle when the battery voltage dropped below 4V. (6081) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Radio Modem support has been added to MJ1 port and removed from MJ3 port. (588) NOTE: Changes available in Cscape 9.90 SP5 onwards. | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | ModbusTCP communication was not starting until Reacquire Time has timed out. (5042) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Modbus TCP communication would stop due to DHCP lease time getting expired. (6101) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Unit would lose communication with Cscape over Ethernet when unit when there are multiple slaves configured in the program but not connected. (4700) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | WebMI license was lost if there is a flat / faulty controller battery - License duration check will not be done for lifetime licenses. So, even if battery fails, license will be valid for lifetime licenses. (3429) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | Remove all options for firmware upgrade except "Install Bootloader". (6333) | Bootloader | |
RCC Series | CSCAN 15.54 | March 2022 | Bug Fix | a. Packets getting delayed beyond the set update interval When Update interval option was selected in the Client protocol (5398) b. Previous sockets were getting closed before sending the re-connect packet (5398) | Bootloader | |
RCC Series | Download Firmware 15.54 Release Notes | |||||
RCC Series | CSCAN 15.52 | May 2021 | Enhancement | Added Ethernet Protocol Reset capabilities for FTP, EGD, Modbus and WebMI protocols – LAN1 and LAN2: %SR156.1 - EGD for LAN1 %SR156.2 - Modbus TCP Slave for LAN1 %SR156.4 - FTP for LAN1 %SR156.5 - WebMI for LAN1 and LAN2 %SR153.1 - EGD for LAN2 %SR153.2 - Modbus TCP Slave for LAN2 %SR153.4 - FTP for LAN2 User should not set other bits of %SR153 and %SR156 to one. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Logic Programming - Enhancements over standard IEC in performance, capacity (>5x), online programming and troubleshooting. | Bootloader, Cscape 9.90 SP4 | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | Enhanced IEC Licensing – Features added. | Bootloader, Cscape 9.90 SP4 | |
RCC Series | CSCAN 15.52 | May 2021 | Licensed Enhancement | MQTT - Expanded offline message buffering from 20 messages / broker to 1024 messages / broker. (5177) | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue which could cause built-in digital inputs (%I) to turn ON during power-down (4789). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Units with part numbers ending in 1E2 only (i.e. HE-XC1E2). Fixed an issue where a power glitch below the operating voltage threshold could cause a relay output to latch ON (3746). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved an issue where it was possible (but typically rare) for the unit to get stuck while booting. This situation could result in complete battery drain if left unresolved. Failure to boot within a short time will now cause the unit to re-initiate the boot, which has consistently proven to resolve the issue. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an issue where units were not shutting down properly when the battery voltage was below 2.0V. | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Resolved issue where Modbus Master ladder block was not working. Port loopback test failed on MJ1, MJ2 &MJ3. (5713) | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | RCC only - Corrected an issue introduced in 15.30 which caused the legacy (pre-WebMI) webserver not to operate (3867). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | RCC only - Fixed an issue wherein it was not possible to recover RCCs with dead batteries (4674). | Bootloader | |
RCC 2414 only | CSCAN 15.52 | May 2021 | Bug Fix | RCC2414 only - Corrected an issue wherein the RCC was not updating the LAN2 EGD status (4024). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the Alarm History was not being maintained after a power cycle (4206). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Corrected an issue where the NTP server was skipping a day after a new year (4910). | Bootloader | |
RCC Series | CSCAN 15.52 | May 2021 | Bug Fix | Fixed an intermittent watchdog issue which could occur immediately after loading a PGM file (4177). | Bootloader | |
RCC Series | Bug Fix | Download Firmware 15.52 Release Notes | ||||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue on internal I/O bus timing preventing the unit from shutting down properly and saving registers. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where a fast power cycle (less than 2 seconds) caused the unit to run on internal battery causing an improper shut down. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed a watchdog issue related to the Horner Wi-Fi module performing a mode change. | ||
RCC Series | CSCAN 15.34 | June 2020 | Bug Fix | Fixed an issue where some applications using the email feature with TLS enabled causing a watchdog reset. | ||
RCC Series | Download Firmware 15.40 Release Notes | |||||
RCC Series | CSCAN 15.30 | October 2019 | Enhancement | BACnet protocol - Allowed configuration of parameters via registers. Added Binary Inputs, Binary Outputs, Binary Values, Analog Inputs & Analog Outputs. Added the ability to select the range of addresses to be mapped / detected in the discovery process. | ||
RCC Series | CSCAN 15.30 | October 2019 | Enhancement | Basic support for Horner HE-WIFIUSB module. Further operational improvements are scheduled for future firmware updates. Support for the HE-WIFIUSB module is NOT possible for the RCC8842, RCC972 or RCC1410. | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Possible reset when copying large files from uSD to USB | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Error using wildcards in Removable Media blocks | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Fixed issue where format size of microSD was limited to 1GB | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Alarms not displayed on web pages in WebMI | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | System exception for some programs due to issue with incorrect value for baud rate for J1939 | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Fixed an issue that prevented login after download | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Date format changed to DD-Mon-YY in retentive trend playback | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Alarm object display did not show live refresh for WebMI | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | Off Delay Timer output was energizing when no power was applied to Timer in first scan | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | HE-X5 touch screen calibration issue where the next button can be hard to press for in-field recalibration | ||
RCC Series | CSCAN 15.30 | October 2019 | Bug Fix | When the password data object is set for user access object type, the visibility does not work as expected. | ||
RCC Series | Download Firmware 15.30 Release Notes | |||||
RCC Series | CSCAN 15.22 | June 2019 | Enhancement | Expanded the temperature range at which battery charging can occur. The Charging Temperature Range Table below lists these ambient temperature values by controller. Refer to the Horner Rechargeable Battery Operation Manual, MAN1142, for more details. | ||
RCC Series | CSCAN 15.22 | June 2019 | ||||
RCC Series | Download Rechargeable Battery Operation Manual | |||||
RCC Series | Download Firmware 15.22 Release Notes |